Developing Benchmarking Metrics for Appropriate Ordering of Vitamin D, Thyroid Testing, and Iron Workups.

IF 1.8 Q3 MEDICAL LABORATORY TECHNOLOGY
Hsuan-Chieh Liao, Alec Saitman, Jane Dickerson
{"title":"Developing Benchmarking Metrics for Appropriate Ordering of Vitamin D, Thyroid Testing, and Iron Workups.","authors":"Hsuan-Chieh Liao, Alec Saitman, Jane Dickerson","doi":"10.1093/jalm/jfae126","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Laboratory stewardship programs are increasingly adopted to enhance test utilization and improve patient care. Despite their potential, implementation within complex healthcare systems remains challenging. Benchmarking metrics helps institutions compare their performance against peers or best practices. However, the application in laboratory stewardship is underrepresented in the literature.</p><p><strong>Methods: </strong>The PLUGS (Patient-centered Laboratory Utiliazation Guidance Services) Informatics Working Group developed guidelines to address common test utilization issues. Metrics were based on data that are easily retrievable and calculable. Three key benchmarks were chosen for a pilot study: the ratio of 25-hydroxyvitamin D to 1,25-dihydroxyvitamin D test orders, the ratio of thyroid-stimulating hormone (TSH) to free thyroxine (FT4) test orders, and the percentage of iron workup orders after an initial low mean corpuscular volume (MCV). Institutions analyzed their own data and we established optimal benchmarks through inter-laboratory comparisons.</p><p><strong>Results: </strong>Nine laboratories evaluated vitamin D testing, with 2 implementing stewardship interventions beforehand. A benchmark of 50:1 was established, where a higher ratio indicates intentional ordering of 1,25-dihydroxyvitamin D. Nine laboratories evaluated thyroid testing, with 3 implementing interventions. The benchmark of 3.5:1 was established, with a higher ratio suggesting judicious TSH ordering. Seven laboratories evaluated iron workups, proposing a benchmark of 50% as a starting metric. Intervention guidelines were provided for laboratories below the benchmarks to promote improvement.</p><p><strong>Conclusions: </strong>Benchmarking metrics provide a standardized framework for assessing and enhancing test utilization practices across multiple laboratories. Continued collaboration and refinement of benchmarking methodologies is essential in maximizing the impact of laboratory stewardship programs on patient safety and resource utilization.</p>","PeriodicalId":46361,"journal":{"name":"Journal of Applied Laboratory Medicine","volume":"10 1","pages":"184-191"},"PeriodicalIF":1.8000,"publicationDate":"2025-01-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Applied Laboratory Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1093/jalm/jfae126","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"MEDICAL LABORATORY TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Laboratory stewardship programs are increasingly adopted to enhance test utilization and improve patient care. Despite their potential, implementation within complex healthcare systems remains challenging. Benchmarking metrics helps institutions compare their performance against peers or best practices. However, the application in laboratory stewardship is underrepresented in the literature.

Methods: The PLUGS (Patient-centered Laboratory Utiliazation Guidance Services) Informatics Working Group developed guidelines to address common test utilization issues. Metrics were based on data that are easily retrievable and calculable. Three key benchmarks were chosen for a pilot study: the ratio of 25-hydroxyvitamin D to 1,25-dihydroxyvitamin D test orders, the ratio of thyroid-stimulating hormone (TSH) to free thyroxine (FT4) test orders, and the percentage of iron workup orders after an initial low mean corpuscular volume (MCV). Institutions analyzed their own data and we established optimal benchmarks through inter-laboratory comparisons.

Results: Nine laboratories evaluated vitamin D testing, with 2 implementing stewardship interventions beforehand. A benchmark of 50:1 was established, where a higher ratio indicates intentional ordering of 1,25-dihydroxyvitamin D. Nine laboratories evaluated thyroid testing, with 3 implementing interventions. The benchmark of 3.5:1 was established, with a higher ratio suggesting judicious TSH ordering. Seven laboratories evaluated iron workups, proposing a benchmark of 50% as a starting metric. Intervention guidelines were provided for laboratories below the benchmarks to promote improvement.

Conclusions: Benchmarking metrics provide a standardized framework for assessing and enhancing test utilization practices across multiple laboratories. Continued collaboration and refinement of benchmarking methodologies is essential in maximizing the impact of laboratory stewardship programs on patient safety and resource utilization.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Applied Laboratory Medicine
Journal of Applied Laboratory Medicine MEDICAL LABORATORY TECHNOLOGY-
CiteScore
3.70
自引率
5.00%
发文量
137
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信