Comparison of marginal fit between milled and three-dimensional printed polymethylmethacrylate prostheses for single crowns, anterior bridges, and pier abutment bridges: An in vitro study.

IF 1 Q3 DENTISTRY, ORAL SURGERY & MEDICINE
The Journal of Indian Prosthodontic Society Pub Date : 2025-01-01 Epub Date: 2025-01-03 DOI:10.4103/jips.jips_40_24
Aman Merchant, Kiran Kumar Pandurangan, Amrutha Dinesh Shenoy, Deepak Nallaswamy, Pooja Nilesh Singh
{"title":"Comparison of marginal fit between milled and three-dimensional printed polymethylmethacrylate prostheses for single crowns, anterior bridges, and pier abutment bridges: An in vitro study.","authors":"Aman Merchant, Kiran Kumar Pandurangan, Amrutha Dinesh Shenoy, Deepak Nallaswamy, Pooja Nilesh Singh","doi":"10.4103/jips.jips_40_24","DOIUrl":null,"url":null,"abstract":"<p><strong>Aim: </strong>The purpose of this in vitro study was to compare the marginal fit of various three-dimensional (3D) printed and milled polymethylmethacrylate (PMMA) dental prostheses.</p><p><strong>Settings and design: </strong>The study was conducted in an in vitro study setting.</p><p><strong>Materials and methods: </strong>With a sample size of 45 for each fabrication method, this investigation compared the marginal fit of milled (Group 1) and 3D printed (Group 2) PMMA dental prostheses across different designs. The selection of samples was based on G*Power calculations. Tooth preparations were conducted on a typodont jaw set, followed by digital scanning and design processes. Computer-aided design and computer-aided manufacturing milling and 3D printing were employed for the fabrication of prostheses. The assessment of marginal accuracy at specific points was performed using a stereomicroscope.</p><p><strong>Statistical analysis used: </strong>Independent t-tests were used to evaluate marginal discrepancies between milled and printed prosthetic designs at specific tooth surfaces. Univariate analysis of variance assessed marginal discrepancies across prosthesis designs and fabrication methods, with the Tukey post hoc test for significantly different results (α =0.05).</p><p><strong>Results: </strong>Milled single crowns exhibited superior accuracy (61.50 ± 4.852 μ) compared to printed ones (65.74 ± 7.311 μ) (t = -1.868, P = 0.037). Similar trends were observed for other designs, emphasizing the impact of both prosthesis design and fabrication method on marginal fit. Notable discrepancies were found on the distal surfaces of the anterior bridge crossing midline design (t = -3.262, P = 0.003).</p><p><strong>Conclusion: </strong>Milled prostheses exhibited superior marginal fit as compared to 3D printed prostheses, with differences within clinically acceptable limits.</p>","PeriodicalId":22669,"journal":{"name":"The Journal of Indian Prosthodontic Society","volume":"25 1","pages":"67-73"},"PeriodicalIF":1.0000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Journal of Indian Prosthodontic Society","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/jips.jips_40_24","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/3 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Aim: The purpose of this in vitro study was to compare the marginal fit of various three-dimensional (3D) printed and milled polymethylmethacrylate (PMMA) dental prostheses.

Settings and design: The study was conducted in an in vitro study setting.

Materials and methods: With a sample size of 45 for each fabrication method, this investigation compared the marginal fit of milled (Group 1) and 3D printed (Group 2) PMMA dental prostheses across different designs. The selection of samples was based on G*Power calculations. Tooth preparations were conducted on a typodont jaw set, followed by digital scanning and design processes. Computer-aided design and computer-aided manufacturing milling and 3D printing were employed for the fabrication of prostheses. The assessment of marginal accuracy at specific points was performed using a stereomicroscope.

Statistical analysis used: Independent t-tests were used to evaluate marginal discrepancies between milled and printed prosthetic designs at specific tooth surfaces. Univariate analysis of variance assessed marginal discrepancies across prosthesis designs and fabrication methods, with the Tukey post hoc test for significantly different results (α =0.05).

Results: Milled single crowns exhibited superior accuracy (61.50 ± 4.852 μ) compared to printed ones (65.74 ± 7.311 μ) (t = -1.868, P = 0.037). Similar trends were observed for other designs, emphasizing the impact of both prosthesis design and fabrication method on marginal fit. Notable discrepancies were found on the distal surfaces of the anterior bridge crossing midline design (t = -3.262, P = 0.003).

Conclusion: Milled prostheses exhibited superior marginal fit as compared to 3D printed prostheses, with differences within clinically acceptable limits.

求助全文
约1分钟内获得全文 求助全文
来源期刊
The Journal of Indian Prosthodontic Society
The Journal of Indian Prosthodontic Society DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
2.20
自引率
8.30%
发文量
26
审稿时长
20 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信