A Simple and Sensitive LC-MS/MS Method for the Determination of Mobocertinib and Its Metabolite Desmethyl-Mobocertinib in Human Plasma and Its Application to Clinical Pharmacokinetic Study.

IF 1.8 4区 医学 Q4 BIOCHEMICAL RESEARCH METHODS
Fan Tang, Xiaoli Hou, Jiajie Chen, Yasen Cao, Yixia Wang, Hong Cheng
{"title":"A Simple and Sensitive LC-MS/MS Method for the Determination of Mobocertinib and Its Metabolite Desmethyl-Mobocertinib in Human Plasma and Its Application to Clinical Pharmacokinetic Study.","authors":"Fan Tang, Xiaoli Hou, Jiajie Chen, Yasen Cao, Yixia Wang, Hong Cheng","doi":"10.1002/bmc.6063","DOIUrl":null,"url":null,"abstract":"<p><p>Mobocertinib is a potent selective tyrosine kinase inhibitor approved for the treatment of non-small cell lung cancer with activating EGFR exon 20 insertions. The aim of this study was to develop a procedure for liquid chromatography tandem mass spectrometry (LC-MS/MS) for the determination of mobocertinib and its metabolite desmethyl-mobocertinib in human plasma. The human plasma samples were precipitated with acetonitrile and analyzed using a Waters ACQUITY BEH C<sub>18</sub> column coupled to a triple quadrupole mass spectrometer. Separation was executed using the acetonitrile-0.1% formic acid solution with gradient elution, at a flow rate of 0.4 mL/min. Mobocertinib and desmethyl-mobocertinib were monitored by multiple reaction monitoring (MRM) with m/z 586.5  >  72.2 and 572.4  >  473.2, respectively. The procedure demonstrated excellent linearity (r > 0.997) within the concentration range of 0.1-200 ng/mL for both analytes. Precision in relative standard deviation was <  9.37% for mobocertinib and <  12.03% for desmethyl-mobocertinib. Accuracy in relative error was within -7.23% to 9.18% for mobocertinib and -2.78% to 9.87% for desmethyl-mobocertinib. Extraction recovery was >  80% for both analytes. The validated LC-MS/MS method was successfully applied to the pharmacokinetic study of mobocertinib and desmethyl-mobocertinib in healthy human volunteers with K<sub>2</sub>EDTA as anticoagulant after a single dose of mobocertinib (160 mg).</p>","PeriodicalId":8861,"journal":{"name":"Biomedical Chromatography","volume":"39 2","pages":"e6063"},"PeriodicalIF":1.8000,"publicationDate":"2025-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomedical Chromatography","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1002/bmc.6063","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

Abstract

Mobocertinib is a potent selective tyrosine kinase inhibitor approved for the treatment of non-small cell lung cancer with activating EGFR exon 20 insertions. The aim of this study was to develop a procedure for liquid chromatography tandem mass spectrometry (LC-MS/MS) for the determination of mobocertinib and its metabolite desmethyl-mobocertinib in human plasma. The human plasma samples were precipitated with acetonitrile and analyzed using a Waters ACQUITY BEH C18 column coupled to a triple quadrupole mass spectrometer. Separation was executed using the acetonitrile-0.1% formic acid solution with gradient elution, at a flow rate of 0.4 mL/min. Mobocertinib and desmethyl-mobocertinib were monitored by multiple reaction monitoring (MRM) with m/z 586.5  >  72.2 and 572.4  >  473.2, respectively. The procedure demonstrated excellent linearity (r > 0.997) within the concentration range of 0.1-200 ng/mL for both analytes. Precision in relative standard deviation was <  9.37% for mobocertinib and <  12.03% for desmethyl-mobocertinib. Accuracy in relative error was within -7.23% to 9.18% for mobocertinib and -2.78% to 9.87% for desmethyl-mobocertinib. Extraction recovery was >  80% for both analytes. The validated LC-MS/MS method was successfully applied to the pharmacokinetic study of mobocertinib and desmethyl-mobocertinib in healthy human volunteers with K2EDTA as anticoagulant after a single dose of mobocertinib (160 mg).

求助全文
约1分钟内获得全文 求助全文
来源期刊
Biomedical Chromatography
Biomedical Chromatography 生物-分析化学
CiteScore
3.60
自引率
5.60%
发文量
268
审稿时长
2.3 months
期刊介绍: Biomedical Chromatography is devoted to the publication of original papers on the applications of chromatography and allied techniques in the biological and medical sciences. Research papers and review articles cover the methods and techniques relevant to the separation, identification and determination of substances in biochemistry, biotechnology, molecular biology, cell biology, clinical chemistry, pharmacology and related disciplines. These include the analysis of body fluids, cells and tissues, purification of biologically important compounds, pharmaco-kinetics and sequencing methods using HPLC, GC, HPLC-MS, TLC, paper chromatography, affinity chromatography, gel filtration, electrophoresis and related techniques.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信