An integrated magnetoimpedance biosensor microfluidic magnetic platform for the evaluation of the cardiac marker cTnI.

IF 2.7 3区 化学 Q2 CHEMISTRY, ANALYTICAL
Zhen Yang, Jingyuan Chen, Mengyu Liu, Jiabao Huang, Jieping Liang, Mengjiao Zhu, Yuanwei Shen, Danqing Li, Chong Lei, Xuecheng Sun
{"title":"An integrated magnetoimpedance biosensor microfluidic magnetic platform for the evaluation of the cardiac marker cTnI.","authors":"Zhen Yang, Jingyuan Chen, Mengyu Liu, Jiabao Huang, Jieping Liang, Mengjiao Zhu, Yuanwei Shen, Danqing Li, Chong Lei, Xuecheng Sun","doi":"10.1039/d4ay02021a","DOIUrl":null,"url":null,"abstract":"<p><p>An integrated magnetoimpedance (MI) biosensor microfluidic magnetic platform was proposed for the evaluation of the cardiac marker, cardiac troponin I (cTnI). This bioanalyte evaluation platform mainly comprised three external permanent magnets (PMs), one MI element, two peelable SiO<sub>2</sub> film units and a microfluidic chip (MFC). The MI element was made of micro-electro-mechanical system (MEMS)-based multilayered [Ti (6 nm)/FeNi (100 nm)]<sub>5</sub>/Cu (400 nm)/[Ti (6 nm)/FeNi (100 nm)]<sub>5</sub> thin films and designed as meander structures with closed magnetic flux. The MFC was fabricated using 3D printing and inverted molding techniques, designed with a solution by mixing the reaction region, magnetic separation region and detection region. Peelable SiO<sub>2</sub> film units with the same size as the MI sensing element were used as the immunoreactivity interface of the bioanalytes. Two large PMs were placed directly below the MI sensing unit to provide a bias magnetic field, and the smaller PM was embedded in MCF for magnetic separation function. Different concentrations of the biological target (cTnI antigen)-, PBS buffer-, and Dynabeads-labeled polyclonal cTnI antibody solution were injected sequentially into the MCF. After immunoreactivity and magnetic separation, a classical sandwich immunoreaction process occurred on the surface of the monoclonal antibody-modified SiO<sub>2</sub> film <i>via</i> self-assembling process in the reaction region of the MFC. The fundamental principle for evaluation of cTnI was based on variations of the MI signal under different concentrations of the biological target coupled with different numbers of Dynabeads. It was demonstrated that the mentioned MI-based magnetic platform could perform quantitative detection analyses over a range of cTnI concentrations (lowest concentration = 0.1 ng mL<sup>-1</sup> and highest concentration = 100 ng mL<sup>-1</sup>). The proposed MI-based magnetic platform provides a sensitive, reliable, stable and reusable bioanalytical platform, and it has potential in future biomedical applications.</p>","PeriodicalId":64,"journal":{"name":"Analytical Methods","volume":" ","pages":""},"PeriodicalIF":2.7000,"publicationDate":"2025-01-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical Methods","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1039/d4ay02021a","RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

An integrated magnetoimpedance (MI) biosensor microfluidic magnetic platform was proposed for the evaluation of the cardiac marker, cardiac troponin I (cTnI). This bioanalyte evaluation platform mainly comprised three external permanent magnets (PMs), one MI element, two peelable SiO2 film units and a microfluidic chip (MFC). The MI element was made of micro-electro-mechanical system (MEMS)-based multilayered [Ti (6 nm)/FeNi (100 nm)]5/Cu (400 nm)/[Ti (6 nm)/FeNi (100 nm)]5 thin films and designed as meander structures with closed magnetic flux. The MFC was fabricated using 3D printing and inverted molding techniques, designed with a solution by mixing the reaction region, magnetic separation region and detection region. Peelable SiO2 film units with the same size as the MI sensing element were used as the immunoreactivity interface of the bioanalytes. Two large PMs were placed directly below the MI sensing unit to provide a bias magnetic field, and the smaller PM was embedded in MCF for magnetic separation function. Different concentrations of the biological target (cTnI antigen)-, PBS buffer-, and Dynabeads-labeled polyclonal cTnI antibody solution were injected sequentially into the MCF. After immunoreactivity and magnetic separation, a classical sandwich immunoreaction process occurred on the surface of the monoclonal antibody-modified SiO2 film via self-assembling process in the reaction region of the MFC. The fundamental principle for evaluation of cTnI was based on variations of the MI signal under different concentrations of the biological target coupled with different numbers of Dynabeads. It was demonstrated that the mentioned MI-based magnetic platform could perform quantitative detection analyses over a range of cTnI concentrations (lowest concentration = 0.1 ng mL-1 and highest concentration = 100 ng mL-1). The proposed MI-based magnetic platform provides a sensitive, reliable, stable and reusable bioanalytical platform, and it has potential in future biomedical applications.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Analytical Methods
Analytical Methods CHEMISTRY, ANALYTICAL-FOOD SCIENCE & TECHNOLOGY
CiteScore
5.10
自引率
3.20%
发文量
569
审稿时长
1.8 months
期刊介绍: Early applied demonstrations of new analytical methods with clear societal impact
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信