Ultrasound-Controllable Release of Carbon Monoxide in Multifunctional Polymer Coating for Synergetic Treatment of Catheter-Related Infections.

IF 10 2区 医学 Q1 ENGINEERING, BIOMEDICAL
Ziqing Liang, Rui Sun, Xu Zhang, Shifang Luan, Hong Xu, Rui Wang, Lingjie Song, Hengchong Shi, Lei Wang
{"title":"Ultrasound-Controllable Release of Carbon Monoxide in Multifunctional Polymer Coating for Synergetic Treatment of Catheter-Related Infections.","authors":"Ziqing Liang, Rui Sun, Xu Zhang, Shifang Luan, Hong Xu, Rui Wang, Lingjie Song, Hengchong Shi, Lei Wang","doi":"10.1002/adhm.202403597","DOIUrl":null,"url":null,"abstract":"<p><p>Medical catheters are susceptible to biological contamination and pathogen invasion, leading to infection and inflammatory complications. The development of antimicrobial coatings for medical devices has emerged as a promising strategy. However, limited biological functionality and the incompatibility between bactericidal properties and biosafety remain great challenges. Herein, a multifunctional polymer coating (CPB-Ac) is created, incorporating an ultrasonic-responsive carbon monoxide release unit (CORM-Ac) and antifouling unit to treat catheter-related complications. As-synthesized CPB-Ac polymer can be stably anchored to various medical devices with arbitrary shapes and compositions via facile UV treatment. Both in vivo and vitro experiments demonstrated that this multi-functional coating exhibits anti-fouling, anti-inflammatory, and broad-spectrum antibacterial activities as well as good biosafety. During the initial implantation phase, the antifouling units of CPB-Ac coating effectively inhibit the attachment of biological contaminants, significantly reducing the risk of thrombosis and bacterial infection. Once bacterial infection occurs, ultrasonic irradiation can activate CPB-Ac coating to release CO with a much higher amount of 55.3 µm than non-ultrasound controls, therefore rapidly eliminating bacteria and alleviating inflammatory response. It is believed that the work may provide an effective method for the development of next-generation intelligent medical coatings against catheter-related complications.</p>","PeriodicalId":113,"journal":{"name":"Advanced Healthcare Materials","volume":" ","pages":"e2403597"},"PeriodicalIF":10.0000,"publicationDate":"2025-01-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advanced Healthcare Materials","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1002/adhm.202403597","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Medical catheters are susceptible to biological contamination and pathogen invasion, leading to infection and inflammatory complications. The development of antimicrobial coatings for medical devices has emerged as a promising strategy. However, limited biological functionality and the incompatibility between bactericidal properties and biosafety remain great challenges. Herein, a multifunctional polymer coating (CPB-Ac) is created, incorporating an ultrasonic-responsive carbon monoxide release unit (CORM-Ac) and antifouling unit to treat catheter-related complications. As-synthesized CPB-Ac polymer can be stably anchored to various medical devices with arbitrary shapes and compositions via facile UV treatment. Both in vivo and vitro experiments demonstrated that this multi-functional coating exhibits anti-fouling, anti-inflammatory, and broad-spectrum antibacterial activities as well as good biosafety. During the initial implantation phase, the antifouling units of CPB-Ac coating effectively inhibit the attachment of biological contaminants, significantly reducing the risk of thrombosis and bacterial infection. Once bacterial infection occurs, ultrasonic irradiation can activate CPB-Ac coating to release CO with a much higher amount of 55.3 µm than non-ultrasound controls, therefore rapidly eliminating bacteria and alleviating inflammatory response. It is believed that the work may provide an effective method for the development of next-generation intelligent medical coatings against catheter-related complications.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Advanced Healthcare Materials
Advanced Healthcare Materials 工程技术-生物材料
CiteScore
14.40
自引率
3.00%
发文量
600
审稿时长
1.8 months
期刊介绍: Advanced Healthcare Materials, a distinguished member of the esteemed Advanced portfolio, has been dedicated to disseminating cutting-edge research on materials, devices, and technologies for enhancing human well-being for over ten years. As a comprehensive journal, it encompasses a wide range of disciplines such as biomaterials, biointerfaces, nanomedicine and nanotechnology, tissue engineering, and regenerative medicine.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信