MXene/PEDOT: PSS composite-modified electrode for electrochemical sensing of bilirubin by molecularly imprinted ortho-phenylenediamine

IF 5.3 2区 化学 Q1 CHEMISTRY, ANALYTICAL
Manoj, Aditya Sharma Ghrera
{"title":"MXene/PEDOT: PSS composite-modified electrode for electrochemical sensing of bilirubin by molecularly imprinted ortho-phenylenediamine","authors":"Manoj,&nbsp;Aditya Sharma Ghrera","doi":"10.1007/s00604-024-06875-3","DOIUrl":null,"url":null,"abstract":"<div><p> For the first time, a Ti<sub>3</sub>C<sub>2</sub>T<sub>x</sub>–MXene and poly (3, 4-ethylenedioxythiophene): poly (styrenesulfonate) (PEDOT: PSS) composite-modified electrode has been developed for electrochemical detection of the bilirubin (BR) by molecularly imprinted ortho-phenylenediamine (o–PD). BR is a biomarker for liver-related diseases. High levels of BR imply liver dysfunction; hence, its exact and rapid measurement is indispensable to its immediate diagnosis and treatment. The synergistic effects of MXene and PEDOT: PSS not only enhanced the electrochemical conductivity and provided a large electroactive surface area for better MIP polymerization but also improved the sensitivity, stability, and electro-catalytic activity of the developed electrode. This is the first study to combine MXene/PEDOT: PSS and molecularly imprinted orthophenylenediamine for BR sensing, which individually have demonstrated potential, but whose combined effects have never been explored in the context of BR detection. The successful synthesis and deposition of composite is confirmed by field emission scanning electron microscopy (FESEM) along with energy dispersive X-ray spectroscopy (EDX) and X-ray diffraction (XRD). The electrochemical properties and surface morphology of the prepared electrode at every modification step were characterized by electrochemical techniques such as cyclic voltammetry (CV), differential pulse voltammetry (DPV) and electrochemical impedance spectroscopy (EIS), and FESEM respectively. The MXene/PEDOT: PSS composite as an electrode modifier exhibited sensing of BR in the clinical relevant range of BR in human serum 0.1–20 mg/dL with a detection limit of 0.002 mg/dL. Additionally, the prepared electrode has excellent reproducibility, stability, selectivity, and repeatability and also showed acceptable results for the sensing of BR in human serum sample.</p><h3>Graphical Abstract</h3>\n<div><figure><div><div><picture><source><img></source></picture></div></div></figure></div></div>","PeriodicalId":705,"journal":{"name":"Microchimica Acta","volume":"192 1","pages":""},"PeriodicalIF":5.3000,"publicationDate":"2025-01-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Microchimica Acta","FirstCategoryId":"92","ListUrlMain":"https://link.springer.com/article/10.1007/s00604-024-06875-3","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

For the first time, a Ti3C2Tx–MXene and poly (3, 4-ethylenedioxythiophene): poly (styrenesulfonate) (PEDOT: PSS) composite-modified electrode has been developed for electrochemical detection of the bilirubin (BR) by molecularly imprinted ortho-phenylenediamine (o–PD). BR is a biomarker for liver-related diseases. High levels of BR imply liver dysfunction; hence, its exact and rapid measurement is indispensable to its immediate diagnosis and treatment. The synergistic effects of MXene and PEDOT: PSS not only enhanced the electrochemical conductivity and provided a large electroactive surface area for better MIP polymerization but also improved the sensitivity, stability, and electro-catalytic activity of the developed electrode. This is the first study to combine MXene/PEDOT: PSS and molecularly imprinted orthophenylenediamine for BR sensing, which individually have demonstrated potential, but whose combined effects have never been explored in the context of BR detection. The successful synthesis and deposition of composite is confirmed by field emission scanning electron microscopy (FESEM) along with energy dispersive X-ray spectroscopy (EDX) and X-ray diffraction (XRD). The electrochemical properties and surface morphology of the prepared electrode at every modification step were characterized by electrochemical techniques such as cyclic voltammetry (CV), differential pulse voltammetry (DPV) and electrochemical impedance spectroscopy (EIS), and FESEM respectively. The MXene/PEDOT: PSS composite as an electrode modifier exhibited sensing of BR in the clinical relevant range of BR in human serum 0.1–20 mg/dL with a detection limit of 0.002 mg/dL. Additionally, the prepared electrode has excellent reproducibility, stability, selectivity, and repeatability and also showed acceptable results for the sensing of BR in human serum sample.

Graphical Abstract

Abstract Image

求助全文
约1分钟内获得全文 求助全文
来源期刊
Microchimica Acta
Microchimica Acta 化学-分析化学
CiteScore
9.80
自引率
5.30%
发文量
410
审稿时长
2.7 months
期刊介绍: As a peer-reviewed journal for analytical sciences and technologies on the micro- and nanoscale, Microchimica Acta has established itself as a premier forum for truly novel approaches in chemical and biochemical analysis. Coverage includes methods and devices that provide expedient solutions to the most contemporary demands in this area. Examples are point-of-care technologies, wearable (bio)sensors, in-vivo-monitoring, micro/nanomotors and materials based on synthetic biology as well as biomedical imaging and targeting.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信