Damiano Caruso, Domenico De Santis, Antonella Del Gaudio, Daniela Valanzuolo, Dominga Pugliese, Marta Zerunian, Michela Polici, Giuseppe Tremamunno, Benedetta Masci, Andrea Laghi
{"title":"Lean body weight-based contrast injection protocol in liver CT: optimization of contrast medium dose.","authors":"Damiano Caruso, Domenico De Santis, Antonella Del Gaudio, Daniela Valanzuolo, Dominga Pugliese, Marta Zerunian, Michela Polici, Giuseppe Tremamunno, Benedetta Masci, Andrea Laghi","doi":"10.1007/s11547-024-01944-2","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>To evaluate liver enhancement and image quality of abdominal CECT examinations acquired with multiple LBW-based contrast medium injection protocols.</p><p><strong>Material & methods: </strong>One hundred fifty patients who underwent a clinically indicated CECT examination were prospectively and randomly assigned to one of the following contrast medium injection protocol groups: A, 700 mg iodine(I)/kg of LBW; B, 650 mgI/kg of LBW; and C, 600 mgI/kg of LBW. Liver signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and magnitude of contrast enhancement (ΔHU) were calculated. Subjective image quality was assessed with 5-point Likert scale.</p><p><strong>Results: </strong>The final population included 145 patients (64 females), with 50, 48, and 47 in group A, B, and C, respectively. Group A showed significantly higher SNR, CNR and ΔHU than group B (p = .018, p = .004, and p = .031, respectively) and group C (p = .024, p = .043, and p = .004). Group B had similar SNR, CNR, and ΔHU to group C (all p = 1). ΔHU was < 50 HU in 2, 7, and 11 patients in group A (48.2 ± 0.1), B (43.7 ± 5), and C (44.4 ± 5), respectively. Group A achieved the highest scores in terms of overall image quality, artifacts, and diagnostic confidence (both scores: 4; IQRs: 4-5) compared to group B (both scores: 3; IQRs: 3-5; p ≥ .037) and group C (overall image quality score: 3; IQR: 2-5; p = .011. Artifact and diagnostic confidence score: 3; IQR: 1-4; p ≥ .009).</p><p><strong>Conclusions: </strong>A dosage of 700 mgI/kg of LBW yields optimal liver enhancement and grants higher image quality compared to lower contrast medium dosages.</p>","PeriodicalId":20817,"journal":{"name":"Radiologia Medica","volume":" ","pages":""},"PeriodicalIF":9.7000,"publicationDate":"2024-12-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiologia Medica","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s11547-024-01944-2","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0
Abstract
Objectives: To evaluate liver enhancement and image quality of abdominal CECT examinations acquired with multiple LBW-based contrast medium injection protocols.
Material & methods: One hundred fifty patients who underwent a clinically indicated CECT examination were prospectively and randomly assigned to one of the following contrast medium injection protocol groups: A, 700 mg iodine(I)/kg of LBW; B, 650 mgI/kg of LBW; and C, 600 mgI/kg of LBW. Liver signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and magnitude of contrast enhancement (ΔHU) were calculated. Subjective image quality was assessed with 5-point Likert scale.
Results: The final population included 145 patients (64 females), with 50, 48, and 47 in group A, B, and C, respectively. Group A showed significantly higher SNR, CNR and ΔHU than group B (p = .018, p = .004, and p = .031, respectively) and group C (p = .024, p = .043, and p = .004). Group B had similar SNR, CNR, and ΔHU to group C (all p = 1). ΔHU was < 50 HU in 2, 7, and 11 patients in group A (48.2 ± 0.1), B (43.7 ± 5), and C (44.4 ± 5), respectively. Group A achieved the highest scores in terms of overall image quality, artifacts, and diagnostic confidence (both scores: 4; IQRs: 4-5) compared to group B (both scores: 3; IQRs: 3-5; p ≥ .037) and group C (overall image quality score: 3; IQR: 2-5; p = .011. Artifact and diagnostic confidence score: 3; IQR: 1-4; p ≥ .009).
Conclusions: A dosage of 700 mgI/kg of LBW yields optimal liver enhancement and grants higher image quality compared to lower contrast medium dosages.
期刊介绍:
Felice Perussia founded La radiologia medica in 1914. It is a peer-reviewed journal and serves as the official journal of the Italian Society of Medical and Interventional Radiology (SIRM). The primary purpose of the journal is to disseminate information related to Radiology, especially advancements in diagnostic imaging and related disciplines. La radiologia medica welcomes original research on both fundamental and clinical aspects of modern radiology, with a particular focus on diagnostic and interventional imaging techniques. It also covers topics such as radiotherapy, nuclear medicine, radiobiology, health physics, and artificial intelligence in the context of clinical implications. The journal includes various types of contributions such as original articles, review articles, editorials, short reports, and letters to the editor. With an esteemed Editorial Board and a selection of insightful reports, the journal is an indispensable resource for radiologists and professionals in related fields. Ultimately, La radiologia medica aims to serve as a platform for international collaboration and knowledge sharing within the radiological community.