{"title":"Impact of titanium mesh cage slotting width on anterior cervical corpectomy and fusion for compression cervical spondylosis with MRI T2WI hyperintensity: a one-year follow-up study.","authors":"Rongguo Yu, Xiurong Yuan, Kangkang Huang, Tingkui Wu, Hong Wang, Chen Ding, Beiyu Wang, Hao Liu","doi":"10.1186/s13018-024-05339-x","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Anterior cervical corpectomy and fusion (ACCF) is a standard surgical procedure for cervical spondylosis with spinal cord compression (CSWSCC), especially in patients with intensity on T2-weighted imaging high signal (T2WIHS). The titanium mesh cage (TMC) utilized in this procedure is essential in stabilizing the spine; however, the optimal slotting width of the TMC remains unclear.</p><p><strong>Objective: </strong>This study aimed to investigate the impact of TMC slotting width on the clinical and radiological outcomes of ACCF in patients with spinal cord compression type cervical spondylosis with intensity on T2WIHS (CST2WIHS).</p><p><strong>Methods: </strong>We retrospectively analyzed 69 patients who underwent single-level ACCF between December 2010 and October 2021. The patients were divided into narrower (< 2 mm) and wider (> 2 mm) groups based on the slotting width of the TMC. The Neck Disability Index (NDI) and Japanese Orthopedic Association (JOA) scores were used to assess clinical outcomes. Radiological outcomes included cervical lordosis (CL), functional spinal unit (FSU) height, transverse decompression range (TDR), spinal canal area (SCA), TMC alignment, and subsidence and fusion rates.</p><p><strong>Results: </strong>Patients in both groups exhibited significant postoperative improvement in NDI and JOA scores (P < 0.05). Radiologically, patients in the wider slotting group exhibited better decompression, evidenced by a larger TDR (P < 0.01) and smaller postoperative SCA (P < 0.01) than the narrow group. Regarding CL, FSU height, TMC alignment, subsidence, or fusion rates, the groups did not differ significantly. Although statistically non-significant, patients in the wider group exhibited a trend towards improvement in spinal cord signal intensity than those in the narrower group.</p><p><strong>Conclusion: </strong>The study demonstrated that a wider TMC slotting width offers superior decompression and may improve postoperative spinal cord signal; it does not compromise spinal stability or fusion outcomes. These findings indicate that slotting width should be carefully considered in ACCF procedures to optimize decompression and spinal cord recovery.</p>","PeriodicalId":16629,"journal":{"name":"Journal of Orthopaedic Surgery and Research","volume":"19 1","pages":"896"},"PeriodicalIF":2.8000,"publicationDate":"2024-12-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11689568/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Orthopaedic Surgery and Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s13018-024-05339-x","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Anterior cervical corpectomy and fusion (ACCF) is a standard surgical procedure for cervical spondylosis with spinal cord compression (CSWSCC), especially in patients with intensity on T2-weighted imaging high signal (T2WIHS). The titanium mesh cage (TMC) utilized in this procedure is essential in stabilizing the spine; however, the optimal slotting width of the TMC remains unclear.
Objective: This study aimed to investigate the impact of TMC slotting width on the clinical and radiological outcomes of ACCF in patients with spinal cord compression type cervical spondylosis with intensity on T2WIHS (CST2WIHS).
Methods: We retrospectively analyzed 69 patients who underwent single-level ACCF between December 2010 and October 2021. The patients were divided into narrower (< 2 mm) and wider (> 2 mm) groups based on the slotting width of the TMC. The Neck Disability Index (NDI) and Japanese Orthopedic Association (JOA) scores were used to assess clinical outcomes. Radiological outcomes included cervical lordosis (CL), functional spinal unit (FSU) height, transverse decompression range (TDR), spinal canal area (SCA), TMC alignment, and subsidence and fusion rates.
Results: Patients in both groups exhibited significant postoperative improvement in NDI and JOA scores (P < 0.05). Radiologically, patients in the wider slotting group exhibited better decompression, evidenced by a larger TDR (P < 0.01) and smaller postoperative SCA (P < 0.01) than the narrow group. Regarding CL, FSU height, TMC alignment, subsidence, or fusion rates, the groups did not differ significantly. Although statistically non-significant, patients in the wider group exhibited a trend towards improvement in spinal cord signal intensity than those in the narrower group.
Conclusion: The study demonstrated that a wider TMC slotting width offers superior decompression and may improve postoperative spinal cord signal; it does not compromise spinal stability or fusion outcomes. These findings indicate that slotting width should be carefully considered in ACCF procedures to optimize decompression and spinal cord recovery.
期刊介绍:
Journal of Orthopaedic Surgery and Research is an open access journal that encompasses all aspects of clinical and basic research studies related to musculoskeletal issues.
Orthopaedic research is conducted at clinical and basic science levels. With the advancement of new technologies and the increasing expectation and demand from doctors and patients, we are witnessing an enormous growth in clinical orthopaedic research, particularly in the fields of traumatology, spinal surgery, joint replacement, sports medicine, musculoskeletal tumour management, hand microsurgery, foot and ankle surgery, paediatric orthopaedic, and orthopaedic rehabilitation. The involvement of basic science ranges from molecular, cellular, structural and functional perspectives to tissue engineering, gait analysis, automation and robotic surgery. Implant and biomaterial designs are new disciplines that complement clinical applications.