Application of additive manufacturing TaBw01 porous tantalum rod in ARCO stage II osteonecrosis of the femoral head.

IF 2.8 3区 医学 Q1 ORTHOPEDICS
Jingjie Huang, Yifan Jiang, Yang Peng, Lina Hao, Ran Xiong, Tiao Su, Guangxing Chen
{"title":"Application of additive manufacturing TaBw01 porous tantalum rod in ARCO stage II osteonecrosis of the femoral head.","authors":"Jingjie Huang, Yifan Jiang, Yang Peng, Lina Hao, Ran Xiong, Tiao Su, Guangxing Chen","doi":"10.1186/s13018-024-05416-1","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>This study aims to investigate the suitable surgical strategies for applying TaBw01 porous tantalum rod across different stages of osteonecrosis of the femoral head (ONFH).</p><p><strong>Methods: </strong>TaBw01 tantalum rods were fabricated using type FTaY-1 tantalum powder via the foam impregnation-sintering method. Mechanical testing with the Instron 8801 universal testing machine and finite element analysis (FEA) assessed single tantalum rod implantation and impaction bone grafting combined with rod implantation. A total of 86 osteonecrosis of the femoral head (ONFH) patients (94 hips) were treated: the experimental group (45 patients, 50 hips) underwent surgical hip dislocation (SHD) with impaction bone grafting and tantalum rod implantation, while the control group (41 patients, 44 hips) received single rod implantation. Primary failure criteria included femoral head collapse (≥ 2 mm) or total hip arthroplasty. Patient-reported outcomes (PROs), including Harris Hip Score (HHS), Visual Analog Score (VAS), Hip Outcome Score Activities of Daily Living Subscale (HOS-ADL), and Hip Outcome Score Sport-Specific Subscale (HOS-SSS), were analyzed based on Minimum Clinically Important Difference (MCID).</p><p><strong>Results: </strong>FEA confirmed stresses below the material's yield and compressive strength. At 3 years, survival rates for ARCO (Association Research Circulation Osseous) stage IIb and IIc were higher in the experimental group (100%, 80.38%) than the control group, while stage IIa survival was 100% in the control group. The experimental group also had higher MCID attainment for HHS, HOS-ADL, and HOS-SSS.</p><p><strong>Conclusions: </strong>Compared with single TaBw01 implantation, impaction bone grafting combined with TaBw01 implantation via SHD demonstrated superior outcomes for ARCO stage IIb and IIc, with a minimum 2-year follow-up. while single TaBw01 implantation may be more suitable for stage IIa. This study emphasizes the importance of combining biological and biomechanical reconstruction in ONFH treatment.</p>","PeriodicalId":16629,"journal":{"name":"Journal of Orthopaedic Surgery and Research","volume":"19 1","pages":"893"},"PeriodicalIF":2.8000,"publicationDate":"2024-12-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11689704/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Orthopaedic Surgery and Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s13018-024-05416-1","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: This study aims to investigate the suitable surgical strategies for applying TaBw01 porous tantalum rod across different stages of osteonecrosis of the femoral head (ONFH).

Methods: TaBw01 tantalum rods were fabricated using type FTaY-1 tantalum powder via the foam impregnation-sintering method. Mechanical testing with the Instron 8801 universal testing machine and finite element analysis (FEA) assessed single tantalum rod implantation and impaction bone grafting combined with rod implantation. A total of 86 osteonecrosis of the femoral head (ONFH) patients (94 hips) were treated: the experimental group (45 patients, 50 hips) underwent surgical hip dislocation (SHD) with impaction bone grafting and tantalum rod implantation, while the control group (41 patients, 44 hips) received single rod implantation. Primary failure criteria included femoral head collapse (≥ 2 mm) or total hip arthroplasty. Patient-reported outcomes (PROs), including Harris Hip Score (HHS), Visual Analog Score (VAS), Hip Outcome Score Activities of Daily Living Subscale (HOS-ADL), and Hip Outcome Score Sport-Specific Subscale (HOS-SSS), were analyzed based on Minimum Clinically Important Difference (MCID).

Results: FEA confirmed stresses below the material's yield and compressive strength. At 3 years, survival rates for ARCO (Association Research Circulation Osseous) stage IIb and IIc were higher in the experimental group (100%, 80.38%) than the control group, while stage IIa survival was 100% in the control group. The experimental group also had higher MCID attainment for HHS, HOS-ADL, and HOS-SSS.

Conclusions: Compared with single TaBw01 implantation, impaction bone grafting combined with TaBw01 implantation via SHD demonstrated superior outcomes for ARCO stage IIb and IIc, with a minimum 2-year follow-up. while single TaBw01 implantation may be more suitable for stage IIa. This study emphasizes the importance of combining biological and biomechanical reconstruction in ONFH treatment.

求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
4.10
自引率
7.70%
发文量
494
审稿时长
>12 weeks
期刊介绍: Journal of Orthopaedic Surgery and Research is an open access journal that encompasses all aspects of clinical and basic research studies related to musculoskeletal issues. Orthopaedic research is conducted at clinical and basic science levels. With the advancement of new technologies and the increasing expectation and demand from doctors and patients, we are witnessing an enormous growth in clinical orthopaedic research, particularly in the fields of traumatology, spinal surgery, joint replacement, sports medicine, musculoskeletal tumour management, hand microsurgery, foot and ankle surgery, paediatric orthopaedic, and orthopaedic rehabilitation. The involvement of basic science ranges from molecular, cellular, structural and functional perspectives to tissue engineering, gait analysis, automation and robotic surgery. Implant and biomaterial designs are new disciplines that complement clinical applications. JOSR encourages the publication of multidisciplinary research with collaboration amongst clinicians and scientists from different disciplines, which will be the trend in the coming decades.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信