Establishment and Application of a Dual Immunoassay Method Based on ICP-MS for Stable Element Labeling Antibodies.

IF 2.6 4区 医学 Q2 MEDICAL LABORATORY TECHNOLOGY
Xuyao Ji, Jing Wu, Jing Zhang, Wenxu Yang, Yu Liu
{"title":"Establishment and Application of a Dual Immunoassay Method Based on ICP-MS for Stable Element Labeling Antibodies.","authors":"Xuyao Ji, Jing Wu, Jing Zhang, Wenxu Yang, Yu Liu","doi":"10.1002/jcla.25145","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>To establish a dual immunoassay based on inductively coupled plasma mass spectrometry (ICP-MS) with stable element labeling antibodies for the simultaneous detection of alpha-fetoprotein (AFP) and prostate-specific antigen (PSA) in serum and evaluate its performance and clinical sample validation.</p><p><strong>Methods: </strong>The immunoassay system based on the double antibody sandwich method was established using magnetic beads as solid-phase carriers and rare earth elements europium (Eu) and samarium (Sm) as element tags. The test conditions were optimized. According to the Clinical Laboratory Standards Institute (CLSI) guidelines and the \"Guidelines for Performance Validation of Clinical Chemistry Quantitative Testing Procedures,\" performance validation was conducted using the established method, followed by clinical sample validation.</p><p><strong>Results: </strong>The LOD and AMR for AFP were 0.76 ng/mL and 1.5-1200 ng/mL, respectively; the LOD and AMR for PSA were 0.41 ng/ mL and 0.5-250 ng/ mL, respectively. The intra-batch precision for AFP and PSA was all less than 3.33%, and the inter-batch precision for AFP and PSA was all less than 4.97%. The recoveries of AFP and PSA were 95.08%-104.18% and 97.65%-100.72%, respectively. The correlation coefficients between the established and the CLIA methods were r = 0.9930 for AFP and r = 0.9852 for PSA.</p><p><strong>Conclusions: </strong>We have developed a dual immunoassay method based on ICP-MS, which can quantitatively detect AFP and PSA in serum within a single analysis. This method exhibits good precision, a wide linear range, and high specificity, meeting the requirements for clinical sample detection and holding potential for clinical application.</p>","PeriodicalId":15509,"journal":{"name":"Journal of Clinical Laboratory Analysis","volume":" ","pages":"e25145"},"PeriodicalIF":2.6000,"publicationDate":"2024-12-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Clinical Laboratory Analysis","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1002/jcla.25145","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MEDICAL LABORATORY TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background: To establish a dual immunoassay based on inductively coupled plasma mass spectrometry (ICP-MS) with stable element labeling antibodies for the simultaneous detection of alpha-fetoprotein (AFP) and prostate-specific antigen (PSA) in serum and evaluate its performance and clinical sample validation.

Methods: The immunoassay system based on the double antibody sandwich method was established using magnetic beads as solid-phase carriers and rare earth elements europium (Eu) and samarium (Sm) as element tags. The test conditions were optimized. According to the Clinical Laboratory Standards Institute (CLSI) guidelines and the "Guidelines for Performance Validation of Clinical Chemistry Quantitative Testing Procedures," performance validation was conducted using the established method, followed by clinical sample validation.

Results: The LOD and AMR for AFP were 0.76 ng/mL and 1.5-1200 ng/mL, respectively; the LOD and AMR for PSA were 0.41 ng/ mL and 0.5-250 ng/ mL, respectively. The intra-batch precision for AFP and PSA was all less than 3.33%, and the inter-batch precision for AFP and PSA was all less than 4.97%. The recoveries of AFP and PSA were 95.08%-104.18% and 97.65%-100.72%, respectively. The correlation coefficients between the established and the CLIA methods were r = 0.9930 for AFP and r = 0.9852 for PSA.

Conclusions: We have developed a dual immunoassay method based on ICP-MS, which can quantitatively detect AFP and PSA in serum within a single analysis. This method exhibits good precision, a wide linear range, and high specificity, meeting the requirements for clinical sample detection and holding potential for clinical application.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Clinical Laboratory Analysis
Journal of Clinical Laboratory Analysis 医学-医学实验技术
CiteScore
5.60
自引率
7.40%
发文量
584
审稿时长
6-12 weeks
期刊介绍: Journal of Clinical Laboratory Analysis publishes original articles on newly developing modes of technology and laboratory assays, with emphasis on their application in current and future clinical laboratory testing. This includes reports from the following fields: immunochemistry and toxicology, hematology and hematopathology, immunopathology, molecular diagnostics, microbiology, genetic testing, immunohematology, and clinical chemistry.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信