Growth of CdZnTe crystal under high magnetic field and its photon-counting detector performance

IF 5.8 2区 材料科学 Q2 CHEMISTRY, PHYSICAL
Jiongjiong Wei, Linjun Wang, Yingdong Huang, Kun Liu, Wanping Liu, Wenxuan Yang, Xiaoyan Liang, Jijun Zhang
{"title":"Growth of CdZnTe crystal under high magnetic field and its photon-counting detector performance","authors":"Jiongjiong Wei, Linjun Wang, Yingdong Huang, Kun Liu, Wanping Liu, Wenxuan Yang, Xiaoyan Liang, Jijun Zhang","doi":"10.1016/j.jallcom.2024.178390","DOIUrl":null,"url":null,"abstract":"In this paper, CdZnTe (CZT) crystal was grown by the Traveling Heater Method (THM) under 5<!-- --> <!-- -->T axial static magnetic field, which improved the quality of CZT crystal and the performance of photon-counting detector. The effect of high magnetic field on the quality of CZT crystal and the mechanism of internal defects were experimentally studied. The concentration of Te inclusions in CZT crystals grown by THM under high magnetic field was about 5×10<sup>3</sup> /cm<sup>3</sup> with the size less than 5μm observed by infrared microscope, which were one order of magnitude lower than those grown without magnetic field. Then the planar CZT detector was fabricated to study the photoelectric properties of CZT crystals grown by THM. The resistivity of CZT under high magnetic field was 2.83×10<sup>10</sup>Ω·cm, and its energy resolution to <sup>241</sup>Am (59.5<!-- --> <!-- -->keV) was 5.9%. The photocurrent maintained a good linearity under the tube current of 0.1mA-0.6<!-- --> <!-- -->mA during the photocurrent response test. The results indicate that the detector prepared by CZT crystal grown under high magnetic field is better than that grown without magnetic field. Finally, the CZT wafers were made into 1×16 linear-array pixel detectors with a pixel size of 0.9×1.8 mm<sup>2</sup>. The photon-counting rate and imaging quality of the CZT linear array detector under X-ray irradiation were studied. The average saturated photon-counting rate reached 2.0×10<sup>6</sup> CPS/Channel (Counts Per Second/Channel).","PeriodicalId":344,"journal":{"name":"Journal of Alloys and Compounds","volume":"25 1","pages":""},"PeriodicalIF":5.8000,"publicationDate":"2024-12-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Alloys and Compounds","FirstCategoryId":"88","ListUrlMain":"https://doi.org/10.1016/j.jallcom.2024.178390","RegionNum":2,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, PHYSICAL","Score":null,"Total":0}
引用次数: 0

Abstract

In this paper, CdZnTe (CZT) crystal was grown by the Traveling Heater Method (THM) under 5 T axial static magnetic field, which improved the quality of CZT crystal and the performance of photon-counting detector. The effect of high magnetic field on the quality of CZT crystal and the mechanism of internal defects were experimentally studied. The concentration of Te inclusions in CZT crystals grown by THM under high magnetic field was about 5×103 /cm3 with the size less than 5μm observed by infrared microscope, which were one order of magnitude lower than those grown without magnetic field. Then the planar CZT detector was fabricated to study the photoelectric properties of CZT crystals grown by THM. The resistivity of CZT under high magnetic field was 2.83×1010Ω·cm, and its energy resolution to 241Am (59.5 keV) was 5.9%. The photocurrent maintained a good linearity under the tube current of 0.1mA-0.6 mA during the photocurrent response test. The results indicate that the detector prepared by CZT crystal grown under high magnetic field is better than that grown without magnetic field. Finally, the CZT wafers were made into 1×16 linear-array pixel detectors with a pixel size of 0.9×1.8 mm2. The photon-counting rate and imaging quality of the CZT linear array detector under X-ray irradiation were studied. The average saturated photon-counting rate reached 2.0×106 CPS/Channel (Counts Per Second/Channel).

Abstract Image

求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Alloys and Compounds
Journal of Alloys and Compounds 工程技术-材料科学:综合
CiteScore
11.10
自引率
14.50%
发文量
5146
审稿时长
67 days
期刊介绍: The Journal of Alloys and Compounds is intended to serve as an international medium for the publication of work on solid materials comprising compounds as well as alloys. Its great strength lies in the diversity of discipline which it encompasses, drawing together results from materials science, solid-state chemistry and physics.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信