{"title":"Evaluation of the drinking water parameters in primary and secondary schools located in the Gaziantep Province Center.","authors":"Osman Petek, Neriman Aydın","doi":"10.2166/wh.2024.311","DOIUrl":null,"url":null,"abstract":"<p><p>This cross-sectional study aimed to assess the drinking water parameters in primary and secondary schools. A questionnaire encompassing the schools' general characteristics and information about drinking water was administered to school administrators. Drinking water samples were taken from 60 schools to evaluate drinking water parameters. The data were analyzed using Chi-Square, Mann-Whitney <i>U</i>, and Kruskall-Wallis tests, <i>T</i>-test, and SPSS 22.0 software. Non-compliance with national legislation was observed in 16.7% of schools during drinking water analysis. The microbiological parameters exceeded the threshold values in 90% of the schools where the analysis results of the drinking water were deemed inadequate. The analysis yielded no discernible variations based on school district or type. Mains water was the primary drinking water source in 91.7% of schools. The rate was lower in rural schools compared to urban schools, with a difference of 85 and 95%, respectively. It was found that 41.7% of schools lacked canteens or the sale of packaged water. Consequently, the availability of tap water in schools falls short of the desired standard. It is imperative to investigate the factors leading to microbiological contamination in school drinking water and formulate short-, medium-, and long-term strategies to enhance its safety.</p>","PeriodicalId":17436,"journal":{"name":"Journal of water and health","volume":"22 12","pages":"2423-2430"},"PeriodicalIF":2.5000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of water and health","FirstCategoryId":"93","ListUrlMain":"https://doi.org/10.2166/wh.2024.311","RegionNum":4,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/11/27 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"ENVIRONMENTAL SCIENCES","Score":null,"Total":0}
引用次数: 0

Abstract

This cross-sectional study aimed to assess the drinking water parameters in primary and secondary schools. A questionnaire encompassing the schools' general characteristics and information about drinking water was administered to school administrators. Drinking water samples were taken from 60 schools to evaluate drinking water parameters. The data were analyzed using Chi-Square, Mann-Whitney U, and Kruskall-Wallis tests, T-test, and SPSS 22.0 software. Non-compliance with national legislation was observed in 16.7% of schools during drinking water analysis. The microbiological parameters exceeded the threshold values in 90% of the schools where the analysis results of the drinking water were deemed inadequate. The analysis yielded no discernible variations based on school district or type. Mains water was the primary drinking water source in 91.7% of schools. The rate was lower in rural schools compared to urban schools, with a difference of 85 and 95%, respectively. It was found that 41.7% of schools lacked canteens or the sale of packaged water. Consequently, the availability of tap water in schools falls short of the desired standard. It is imperative to investigate the factors leading to microbiological contamination in school drinking water and formulate short-, medium-, and long-term strategies to enhance its safety.

加济安泰普省中心的中小学饮用水参数评价。
本横断面研究旨在评估中小学校的饮用水参数。向学校管理人员发放了一份包含学校一般特征和饮用水信息的问卷。从60所学校抽取饮用水样本,对饮用水参数进行评价。采用卡方检验、Mann-Whitney U检验、Kruskall-Wallis检验、t检验和SPSS 22.0软件对数据进行分析。在饮用水分析中发现有16.7%的学校不符合国家立法。在饮用水分析结果被认为不合格的学校中,90%的学校微生物参数超过了阈值。分析没有发现基于学区或类型的明显变化。91.7%的学校以自来水为主要饮用水源。与城市学校相比,农村学校的这一比例较低,分别为85%和95%。调查发现,41.7%的学校没有食堂或没有销售瓶装水。因此,学校自来水的供应达不到预期的标准。研究学校饮用水中微生物污染的影响因素,制定提高学校饮用水安全的短期、中期和长期对策是当务之急。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of water and health
Journal of water and health 环境科学-环境科学
CiteScore
3.60
自引率
8.70%
发文量
110
审稿时长
18-36 weeks
期刊介绍: Journal of Water and Health is a peer-reviewed journal devoted to the dissemination of information on the health implications and control of waterborne microorganisms and chemical substances in the broadest sense for developing and developed countries worldwide. This is to include microbial toxins, chemical quality and the aesthetic qualities of water.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信