Is the 99th Percentile Cutoff Still Relevant? A Single-Center Assessment of Different Thresholds for Diagnosing Antiphospholipid Syndrome.

IF 1.8 Q3 MEDICAL LABORATORY TECHNOLOGY
Alexis Dadelahi, Brandon S Walker, Dipanwita Banerjee, Michael Mahler, Abdulrahman Saadalla, Vijayalakshmi Nandakumar
{"title":"Is the 99th Percentile Cutoff Still Relevant? A Single-Center Assessment of Different Thresholds for Diagnosing Antiphospholipid Syndrome.","authors":"Alexis Dadelahi, Brandon S Walker, Dipanwita Banerjee, Michael Mahler, Abdulrahman Saadalla, Vijayalakshmi Nandakumar","doi":"10.1093/jalm/jfae149","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The 2023 American College of Rheumatology and modified Sapporo criteria for antiphospholipid syndrome (APS) recommend ELISA to detect anticardiolipin (aCL) and anti-β2-glycoprotein I (aβ2GP1) IgG/IgM antibodies, focusing on moderate to high levels or exceeding the 99th percentile. This study aims to establish the 99th percentile threshold for anti-phospholipid (aPL) antibodies and compare the diagnostic accuracies of these thresholds with manufacturer cutoffs using 2 methodologies.</p><p><strong>Methods: </strong>The 99th percentile cutoffs for aPL antibodies from 305 healthy donors were established using Aptiva, Particle-Based Multi-Analyte Technology (PMAT), and QUANTA Lite (QL) ELISA, following nonparametric reference interval estimation. Sera from 34 APS patients and 190 APS controls were tested. Diagnostic performances were compared at the 99th percentile-, manufacturer-, receiver operating characteristic (ROC) derived optimal-, and 95% specificity-optimized cutoffs. An expanded cohort of 61 APS patients and 1299 APS controls from a 2-year retrospective review was also included.</p><p><strong>Results: </strong>For ELISA, the 99th percentile cutoffs for aCL (IgG/IgM) and aβ2GP1 (IgG) were at the assay limit of quantification. Optimal cutoffs from the ROC curves, 95% specificity-matched and manufacturer cutoffs, showed better diagnostic accuracy than the 99th percentile. On the Aptiva PMAT platform, the 99th percentile cutoffs were lower but provided comparable diagnostic accuracies to manufacturer and optimal cutoffs, although specificity was below 95%.</p><p><strong>Conclusions: </strong>The clinical utility of 99th percentile cutoffs is assay dependent. For QL, these cutoffs were unsuitable, while Aptiva showed better alignment with clinical thresholds. Manufacturer-recommended cutoffs, supported by extensive validation, offer a reliable alternative when clinical studies are infeasible.</p>","PeriodicalId":46361,"journal":{"name":"Journal of Applied Laboratory Medicine","volume":" ","pages":""},"PeriodicalIF":1.8000,"publicationDate":"2024-12-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Applied Laboratory Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1093/jalm/jfae149","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"MEDICAL LABORATORY TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background: The 2023 American College of Rheumatology and modified Sapporo criteria for antiphospholipid syndrome (APS) recommend ELISA to detect anticardiolipin (aCL) and anti-β2-glycoprotein I (aβ2GP1) IgG/IgM antibodies, focusing on moderate to high levels or exceeding the 99th percentile. This study aims to establish the 99th percentile threshold for anti-phospholipid (aPL) antibodies and compare the diagnostic accuracies of these thresholds with manufacturer cutoffs using 2 methodologies.

Methods: The 99th percentile cutoffs for aPL antibodies from 305 healthy donors were established using Aptiva, Particle-Based Multi-Analyte Technology (PMAT), and QUANTA Lite (QL) ELISA, following nonparametric reference interval estimation. Sera from 34 APS patients and 190 APS controls were tested. Diagnostic performances were compared at the 99th percentile-, manufacturer-, receiver operating characteristic (ROC) derived optimal-, and 95% specificity-optimized cutoffs. An expanded cohort of 61 APS patients and 1299 APS controls from a 2-year retrospective review was also included.

Results: For ELISA, the 99th percentile cutoffs for aCL (IgG/IgM) and aβ2GP1 (IgG) were at the assay limit of quantification. Optimal cutoffs from the ROC curves, 95% specificity-matched and manufacturer cutoffs, showed better diagnostic accuracy than the 99th percentile. On the Aptiva PMAT platform, the 99th percentile cutoffs were lower but provided comparable diagnostic accuracies to manufacturer and optimal cutoffs, although specificity was below 95%.

Conclusions: The clinical utility of 99th percentile cutoffs is assay dependent. For QL, these cutoffs were unsuitable, while Aptiva showed better alignment with clinical thresholds. Manufacturer-recommended cutoffs, supported by extensive validation, offer a reliable alternative when clinical studies are infeasible.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Applied Laboratory Medicine
Journal of Applied Laboratory Medicine MEDICAL LABORATORY TECHNOLOGY-
CiteScore
3.70
自引率
5.00%
发文量
137
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信