Enhanced Metabolic Control in a Pediatric Population with Type 1 Diabetes Mellitus Using Hybrid Closed-Loop and Predictive Low-Glucose Suspend Insulin Pump Treatments.

IF 1.4 Q3 PEDIATRICS
Irina Bojoga, Sorin Ioacara, Elisabeta Malinici, Victor Chiper, Olivia Georgescu, Anca Elena Sirbu, Simona Fica
{"title":"Enhanced Metabolic Control in a Pediatric Population with Type 1 Diabetes Mellitus Using Hybrid Closed-Loop and Predictive Low-Glucose Suspend Insulin Pump Treatments.","authors":"Irina Bojoga, Sorin Ioacara, Elisabeta Malinici, Victor Chiper, Olivia Georgescu, Anca Elena Sirbu, Simona Fica","doi":"10.3390/pediatric16040100","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Insulin pumps coupled with continuous glucose monitoring sensors use algorithms to analyze real-time blood glucose levels. This allows for the suspension of insulin administration before hypoglycemic thresholds are reached or for adaptive tuning in hybrid closed-loop systems. This longitudinal retrospective study aims to analyze real-world glycemic outcomes in a pediatric population transitioning to such devices.</p><p><strong>Methods: </strong>We evaluated children with type 1 diabetes mellitus (T1D) admitted to the Pediatric Diabetes Department from a major University Hospital in Bucharest, Romania, who transitioned to hybrid closed-loop or predictive low-glucose suspend system from either non-automated insulin pumps or multiple daily injections. The primary outcome was assessing the change in glycated hemoglobin (HbA1c) after initiating these devices. Secondary outcomes analyzed changes in glucose metrics from the 90 days prior to the baseline and follow-up visit.</p><p><strong>Results: </strong>51 children were included (58.8% girls), the mean age was 10.3 ± 3.7 years, and the mean follow-up duration was 13.2 ± 4.5 months. The analyzed parameters, such as HbA1c (6.9 ± 0.7% vs. 6.7 ± 0.6%, <i>p</i> = 0.023), time in range (69.3 ± 11.2% vs. 76 ± 9.9%, <i>p</i> < 0.001), time in tight range (47.4 ± 10.9% vs. 53.7 ± 10.7%, <i>p</i> < 0.001), time below range (5.6 ± 2.9% vs. 3.5 ± 1.9%, <i>p</i> < 0.001), time above range (25 ± 11.2% vs. 20.4 ± 9.4%, <i>p</i> = 0.001), and coefficient of variation (37.9 ± 4.8% vs. 35.6 ± 4.6%, <i>p</i> = 0.001), showed significant improvements.</p><p><strong>Conclusions: </strong>The application of these sensor-integrated insulin pumps can significantly enhance metabolic control in pediatric populations, minimizing glycemic variations to mitigate complications and enrich the quality of life.</p>","PeriodicalId":45251,"journal":{"name":"Pediatric Reports","volume":"16 4","pages":"1188-1199"},"PeriodicalIF":1.4000,"publicationDate":"2024-12-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11677866/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pediatric Reports","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/pediatric16040100","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"PEDIATRICS","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Insulin pumps coupled with continuous glucose monitoring sensors use algorithms to analyze real-time blood glucose levels. This allows for the suspension of insulin administration before hypoglycemic thresholds are reached or for adaptive tuning in hybrid closed-loop systems. This longitudinal retrospective study aims to analyze real-world glycemic outcomes in a pediatric population transitioning to such devices.

Methods: We evaluated children with type 1 diabetes mellitus (T1D) admitted to the Pediatric Diabetes Department from a major University Hospital in Bucharest, Romania, who transitioned to hybrid closed-loop or predictive low-glucose suspend system from either non-automated insulin pumps or multiple daily injections. The primary outcome was assessing the change in glycated hemoglobin (HbA1c) after initiating these devices. Secondary outcomes analyzed changes in glucose metrics from the 90 days prior to the baseline and follow-up visit.

Results: 51 children were included (58.8% girls), the mean age was 10.3 ± 3.7 years, and the mean follow-up duration was 13.2 ± 4.5 months. The analyzed parameters, such as HbA1c (6.9 ± 0.7% vs. 6.7 ± 0.6%, p = 0.023), time in range (69.3 ± 11.2% vs. 76 ± 9.9%, p < 0.001), time in tight range (47.4 ± 10.9% vs. 53.7 ± 10.7%, p < 0.001), time below range (5.6 ± 2.9% vs. 3.5 ± 1.9%, p < 0.001), time above range (25 ± 11.2% vs. 20.4 ± 9.4%, p = 0.001), and coefficient of variation (37.9 ± 4.8% vs. 35.6 ± 4.6%, p = 0.001), showed significant improvements.

Conclusions: The application of these sensor-integrated insulin pumps can significantly enhance metabolic control in pediatric populations, minimizing glycemic variations to mitigate complications and enrich the quality of life.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Pediatric Reports
Pediatric Reports PEDIATRICS-
CiteScore
2.10
自引率
0.00%
发文量
55
审稿时长
11 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信