Evaluation of change in the contact of IOL with the posterior capsule with respect to the orientation of haptics of the IOL using intraoperative spectral domain optical coherence tomography.

IF 2.1 4区 医学 Q2 OPHTHALMOLOGY
Naren Shetty, Yash Patel, Reshma Ranade, Akash Jain, Raghav Narasimhan, Apurva Bansod, Rudy Nuijts
{"title":"Evaluation of change in the contact of IOL with the posterior capsule with respect to the orientation of haptics of the IOL using intraoperative spectral domain optical coherence tomography.","authors":"Naren Shetty, Yash Patel, Reshma Ranade, Akash Jain, Raghav Narasimhan, Apurva Bansod, Rudy Nuijts","doi":"10.4103/IJO.IJO_348_24","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To study change in the contact of intraocular lens (IOL) with the posterior capsule with respect to the vertical versus horizontal orientation of the haptic-optic junction of the IOL using intraoperative spectral domain optical coherence tomography (SD-OCT).</p><p><strong>Methods: </strong>Fifty eyes of 50 patients with senile immature cataract underwent topical phacoemulsification procedure with implantation of a monofocal IOL by a single experienced surgeon. The Rescan 700 SD-OCT system was used for intraoperative imaging. These patients were imaged using intraoperative SD-OCT after implantation of IOL, with the haptics oriented horizontally and then vertically.</p><p><strong>Results: </strong>The vertical height between the posterior surface of the lens capsule and the posterior surface of IOL reduced significantly when the haptics were oriented vertically compared to horizontal orientation. This difference was found on analyzing both vertical as well as horizontal axis scans.</p><p><strong>Conclusion: </strong>We found a greater contact between the posterior capsule and the posterior surface of IOL, with the haptic optic junction of the IOL oriented vertically. This study also suggests the need for newer toric IOL designs which allow vertical orientation of haptics, leading to better contact between IOL and the bag.</p>","PeriodicalId":13329,"journal":{"name":"Indian Journal of Ophthalmology","volume":" ","pages":""},"PeriodicalIF":2.1000,"publicationDate":"2024-12-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Indian Journal of Ophthalmology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.4103/IJO.IJO_348_24","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To study change in the contact of intraocular lens (IOL) with the posterior capsule with respect to the vertical versus horizontal orientation of the haptic-optic junction of the IOL using intraoperative spectral domain optical coherence tomography (SD-OCT).

Methods: Fifty eyes of 50 patients with senile immature cataract underwent topical phacoemulsification procedure with implantation of a monofocal IOL by a single experienced surgeon. The Rescan 700 SD-OCT system was used for intraoperative imaging. These patients were imaged using intraoperative SD-OCT after implantation of IOL, with the haptics oriented horizontally and then vertically.

Results: The vertical height between the posterior surface of the lens capsule and the posterior surface of IOL reduced significantly when the haptics were oriented vertically compared to horizontal orientation. This difference was found on analyzing both vertical as well as horizontal axis scans.

Conclusion: We found a greater contact between the posterior capsule and the posterior surface of IOL, with the haptic optic junction of the IOL oriented vertically. This study also suggests the need for newer toric IOL designs which allow vertical orientation of haptics, leading to better contact between IOL and the bag.

求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
3.80
自引率
19.40%
发文量
1963
审稿时长
38 weeks
期刊介绍: Indian Journal of Ophthalmology covers clinical, experimental, basic science research and translational research studies related to medical, ethical and social issues in field of ophthalmology and vision science. Articles with clinical interest and implications will be given preference.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信