{"title":"Lithium-ion battery equivalent thermal conductivity testing method based on Bayesian optimization algorithm","authors":"Fang Wang, Ruihao Liu, Xiaole Ma, Yuxuan Zhang, Guangli Bai, Biao Ma, Danhua Li, Zhen Wei, Shiqiang Liu, Yueying Zhu","doi":"10.1007/s10973-024-13884-0","DOIUrl":null,"url":null,"abstract":"<div><p>The thermal conductivity is one of the key thermal property's parameters in the design, modeling, and simulation of lithium-ion battery thermal management systems. Accurate measurement of thermal conductivity allows for a deep understanding of the heat transfer behavior inside lithium-ion batteries, providing essential insights for optimizing battery design, enhancing energy density, and improving safety. In this study, the surface temperature variation data of lithium-ion batteries were obtained by externally heating the batteries using a constant pressure source in an accelerating rate calorimeter enhanced system (ARC). Based on the Fourier one-dimensional heat conduction model, the average specific heat capacity and vertical thermal conductivity of the lithium-ion batteries were calculated. Additionally, the Bayesian optimization algorithm was employed to significantly reduce the number of iterations and rapidly invert the in-plane thermal conductivity of the batteries. The accuracy of the thermal conductivity measurement results was verified by comparing the consistency between experimental and simulation data. The results indicate that the transient deviation between experimental and simulation data at each temperature measurement point does not exceed 0.2 °C, demonstrating the high accuracy of the proposed method. Furthermore, the thermal conductivity of the lithium-ion battery was measured using the Hot Disk method for comparative validation. The results show that the maximum transient deviation of the Hot Disk data is 0.4 °C, indicating that compared to the Hot Disk method, the proposed method exhibits higher accuracy.</p></div>","PeriodicalId":678,"journal":{"name":"Journal of Thermal Analysis and Calorimetry","volume":"149 24","pages":"15073 - 15083"},"PeriodicalIF":3.0000,"publicationDate":"2024-12-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Thermal Analysis and Calorimetry","FirstCategoryId":"5","ListUrlMain":"https://link.springer.com/article/10.1007/s10973-024-13884-0","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0
Abstract
The thermal conductivity is one of the key thermal property's parameters in the design, modeling, and simulation of lithium-ion battery thermal management systems. Accurate measurement of thermal conductivity allows for a deep understanding of the heat transfer behavior inside lithium-ion batteries, providing essential insights for optimizing battery design, enhancing energy density, and improving safety. In this study, the surface temperature variation data of lithium-ion batteries were obtained by externally heating the batteries using a constant pressure source in an accelerating rate calorimeter enhanced system (ARC). Based on the Fourier one-dimensional heat conduction model, the average specific heat capacity and vertical thermal conductivity of the lithium-ion batteries were calculated. Additionally, the Bayesian optimization algorithm was employed to significantly reduce the number of iterations and rapidly invert the in-plane thermal conductivity of the batteries. The accuracy of the thermal conductivity measurement results was verified by comparing the consistency between experimental and simulation data. The results indicate that the transient deviation between experimental and simulation data at each temperature measurement point does not exceed 0.2 °C, demonstrating the high accuracy of the proposed method. Furthermore, the thermal conductivity of the lithium-ion battery was measured using the Hot Disk method for comparative validation. The results show that the maximum transient deviation of the Hot Disk data is 0.4 °C, indicating that compared to the Hot Disk method, the proposed method exhibits higher accuracy.
期刊介绍:
Journal of Thermal Analysis and Calorimetry is a fully peer reviewed journal publishing high quality papers covering all aspects of thermal analysis, calorimetry, and experimental thermodynamics. The journal publishes regular and special issues in twelve issues every year. The following types of papers are published: Original Research Papers, Short Communications, Reviews, Modern Instruments, Events and Book reviews.
The subjects covered are: thermogravimetry, derivative thermogravimetry, differential thermal analysis, thermodilatometry, differential scanning calorimetry of all types, non-scanning calorimetry of all types, thermometry, evolved gas analysis, thermomechanical analysis, emanation thermal analysis, thermal conductivity, multiple techniques, and miscellaneous thermal methods (including the combination of the thermal method with various instrumental techniques), theory and instrumentation for thermal analysis and calorimetry.