Novel electroretinography devices to detect hydroxychloroquine retinopathy: study protocol for a diagnostic accuracy and feasibility study.

IF 2 Q2 OPHTHALMOLOGY
Chan Ning Lee, Hatem A Wafa, George Murphy, James Galloway, Omar A Mahroo, Timothy L Jackson
{"title":"Novel electroretinography devices to detect hydroxychloroquine retinopathy: study protocol for a diagnostic accuracy and feasibility study.","authors":"Chan Ning Lee, Hatem A Wafa, George Murphy, James Galloway, Omar A Mahroo, Timothy L Jackson","doi":"10.1136/bmjophth-2024-001898","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Annual screening for hydroxychloroquine (HCQ) retinopathy is recommended, and electroretinography (ERG) is considered a gold-standard test, but there are screening shortfalls and standard ERG is burdensome and has limited availability. Newer, portable ERG devices using skin-based electrodes may increase screening capacity but need validation. This study aims to determine initial device accuracies and feasibility of further research.</p><p><strong>Methods and analysis: </strong>Prospective diagnostic device accuracy and feasibility study comparing novel ERG devices to standard screening tests. Three groups of 35 participants on HCQ, categorised by HCQ retinopathy (definite, possible and no retinopathy), and 35 healthy control participants, recruited by consecutive sampling, will have full field and multifocal ERG index tests, delivered using skin-contact electrodes by two devices-RETEval full-field and UTAS multifocal ERG, both manufactured by LKC Technologies (Gaithersburg, Maryland, USA), compared with spectral-domain optical coherence tomography and autofluorescence reference tests graded by two masked, independent retinal specialists. Eligible HCQ participants will either have diagnosed HCQ retinopathy or be eligible for screening per UK guidelines. Healthy control participants will have no prior HCQ exposure and be of similar age and sex to HCQ participants. Primary outcome is device-specific sensitivity and specificity. Secondary outcomes include the effect of dilation on device outputs, analysis of discriminatory waveforms, device acceptability and recruitment rate. Safety outcomes include adverse and serious adverse events and device events.</p><p><strong>Ethics and dissemination: </strong>Cambridge East ethics committee gave a favourable opinion (24/EE/0011, 23/02/2024). Results will be published in a peer-reviewed ophthalmology journal.</p><p><strong>Trial registration number: </strong>ClinicalTrials.gov NCT06035887.</p>","PeriodicalId":9286,"journal":{"name":"BMJ Open Ophthalmology","volume":"9 1","pages":""},"PeriodicalIF":2.0000,"publicationDate":"2024-12-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11683940/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"BMJ Open Ophthalmology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1136/bmjophth-2024-001898","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: Annual screening for hydroxychloroquine (HCQ) retinopathy is recommended, and electroretinography (ERG) is considered a gold-standard test, but there are screening shortfalls and standard ERG is burdensome and has limited availability. Newer, portable ERG devices using skin-based electrodes may increase screening capacity but need validation. This study aims to determine initial device accuracies and feasibility of further research.

Methods and analysis: Prospective diagnostic device accuracy and feasibility study comparing novel ERG devices to standard screening tests. Three groups of 35 participants on HCQ, categorised by HCQ retinopathy (definite, possible and no retinopathy), and 35 healthy control participants, recruited by consecutive sampling, will have full field and multifocal ERG index tests, delivered using skin-contact electrodes by two devices-RETEval full-field and UTAS multifocal ERG, both manufactured by LKC Technologies (Gaithersburg, Maryland, USA), compared with spectral-domain optical coherence tomography and autofluorescence reference tests graded by two masked, independent retinal specialists. Eligible HCQ participants will either have diagnosed HCQ retinopathy or be eligible for screening per UK guidelines. Healthy control participants will have no prior HCQ exposure and be of similar age and sex to HCQ participants. Primary outcome is device-specific sensitivity and specificity. Secondary outcomes include the effect of dilation on device outputs, analysis of discriminatory waveforms, device acceptability and recruitment rate. Safety outcomes include adverse and serious adverse events and device events.

Ethics and dissemination: Cambridge East ethics committee gave a favourable opinion (24/EE/0011, 23/02/2024). Results will be published in a peer-reviewed ophthalmology journal.

Trial registration number: ClinicalTrials.gov NCT06035887.

求助全文
约1分钟内获得全文 求助全文
来源期刊
BMJ Open Ophthalmology
BMJ Open Ophthalmology OPHTHALMOLOGY-
CiteScore
3.40
自引率
4.20%
发文量
104
审稿时长
20 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信