Predicting Time in Range Without Hypoglycaemia Using a Risk Calculator for Intermittently Scanned CGM in Type 1 Diabetes.

IF 2.7 Q3 ENDOCRINOLOGY & METABOLISM
Fernando Sebastian-Valles, Jose Alfonso Arranz Martin, Julia Martínez-Alfonso, Jessica Jiménez-Díaz, Iñigo Hernando Alday, Victor Navas-Moreno, Teresa Armenta Joya, Maria Del Mar Del Fandiño García, Gisela Liz Román Gómez, Jon Garai Hierro, Luis Eduardo Lander Lobariñas, Carmen González-Ávila, Purificación de Martinez de Icaya, Vicente Martínez-Vizcaíno, Miguel Antonio Sampedro-Nuñez, Mónica Marazuela
{"title":"Predicting Time in Range Without Hypoglycaemia Using a Risk Calculator for Intermittently Scanned CGM in Type 1 Diabetes.","authors":"Fernando Sebastian-Valles, Jose Alfonso Arranz Martin, Julia Martínez-Alfonso, Jessica Jiménez-Díaz, Iñigo Hernando Alday, Victor Navas-Moreno, Teresa Armenta Joya, Maria Del Mar Del Fandiño García, Gisela Liz Román Gómez, Jon Garai Hierro, Luis Eduardo Lander Lobariñas, Carmen González-Ávila, Purificación de Martinez de Icaya, Vicente Martínez-Vizcaíno, Miguel Antonio Sampedro-Nuñez, Mónica Marazuela","doi":"10.1002/edm2.70020","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To investigate the impact of clinical and socio-economic factors on glycaemic control and construct statistical models to predict optimal glycaemic control (OGC) after implementing intermittently scanned continuous glucose monitoring (isCGM) systems.</p><p><strong>Methods: </strong>This retrospective study included 1072 type 1 diabetes patients (49.0% female) from three centres using isCGM systems. Clinical data and net income from the census tract were collected for each individual. OGC was defined as time in range > 70%, with time below 70 mg/dL < 4%. The sample was randomly split in two equal parts. Logistic regression models to predict OGC were developed in one of the samples, and the best model was selected using the Akaike information criterion and adjusted for Pearson's and Hosmer-Lemeshow's statistics. Model reliability was assessed via external validation in the second sample and internal validation using bootstrap resampling.</p><p><strong>Results: </strong>Out of 2314 models explored, the most effective predictor model included annual net income per person, sex, age, diabetes duration, pre-isCGM HbA1c, insulin dose/kg, and the interaction between sex and HbA1c. When applied to the validation cohort, this model demonstrated 72.6% specificity, 67.3% sensitivity, and an area under the curve (AUC) of 0.736. The AUC through bootstrap resampling was 0.756. Overall, the model's validity in the external cohort was 80.4%.</p><p><strong>Conclusions: </strong>Clinical and socio-economic factors significantly influence OGC in type 1 diabetes. The application of statistical models offers a reliable means of predicting the likelihood of achieving OGC following isCGM system implementation.</p>","PeriodicalId":36522,"journal":{"name":"Endocrinology, Diabetes and Metabolism","volume":"8 1","pages":"e70020"},"PeriodicalIF":2.7000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Endocrinology, Diabetes and Metabolism","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1002/edm2.70020","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENDOCRINOLOGY & METABOLISM","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To investigate the impact of clinical and socio-economic factors on glycaemic control and construct statistical models to predict optimal glycaemic control (OGC) after implementing intermittently scanned continuous glucose monitoring (isCGM) systems.

Methods: This retrospective study included 1072 type 1 diabetes patients (49.0% female) from three centres using isCGM systems. Clinical data and net income from the census tract were collected for each individual. OGC was defined as time in range > 70%, with time below 70 mg/dL < 4%. The sample was randomly split in two equal parts. Logistic regression models to predict OGC were developed in one of the samples, and the best model was selected using the Akaike information criterion and adjusted for Pearson's and Hosmer-Lemeshow's statistics. Model reliability was assessed via external validation in the second sample and internal validation using bootstrap resampling.

Results: Out of 2314 models explored, the most effective predictor model included annual net income per person, sex, age, diabetes duration, pre-isCGM HbA1c, insulin dose/kg, and the interaction between sex and HbA1c. When applied to the validation cohort, this model demonstrated 72.6% specificity, 67.3% sensitivity, and an area under the curve (AUC) of 0.736. The AUC through bootstrap resampling was 0.756. Overall, the model's validity in the external cohort was 80.4%.

Conclusions: Clinical and socio-economic factors significantly influence OGC in type 1 diabetes. The application of statistical models offers a reliable means of predicting the likelihood of achieving OGC following isCGM system implementation.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Endocrinology, Diabetes and Metabolism
Endocrinology, Diabetes and Metabolism Medicine-Endocrinology, Diabetes and Metabolism
CiteScore
5.00
自引率
0.00%
发文量
66
审稿时长
6 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信