Simultaneous Bilateral T1, T2, and T Relaxation Mapping of Hip Joint With 3D-MRI Fingerprinting.

IF 3.3 2区 医学 Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Anmol Monga, Hector Lise de Moura, Marcelo V W Zibetti, Thomas Youm, Jonathan Samuels, Ravinder R Regatte
{"title":"Simultaneous Bilateral T<sub>1</sub>, T<sub>2</sub>, and T<sub>1ρ</sub> Relaxation Mapping of Hip Joint With 3D-MRI Fingerprinting.","authors":"Anmol Monga, Hector Lise de Moura, Marcelo V W Zibetti, Thomas Youm, Jonathan Samuels, Ravinder R Regatte","doi":"10.1002/jmri.29679","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Three-dimensional MR fingerprinting (3D-MRF) has been increasingly used to assess cartilage degeneration, particularly in the knee joint, by looking into multiple relaxation parameters. A comparable 3D-MRF approach can be adapted to assess cartilage degeneration for the hip joint, with changes to accommodate specific challenges of hip joint imaging.</p><p><strong>Purpose: </strong>To demonstrate the feasibility and repeatability of 3D-MRF in the bilateral hip jointly we map proton density (PD), T<sub>1</sub>, T<sub>2</sub>, T<sub>1ρ</sub>, and ∆B<sub>1+</sub> in clinically feasible scan times.</p><p><strong>Study type: </strong>Prospective.</p><p><strong>Subjects: </strong>Eight healthy subjects, three patients with mild osteoarthritis (OA), and one of the OA patients had femoral acetabular impingement (FAI). A National Institute of Standards and Technology/International Society for Magnetic Resonance in Medicine (NIST/ISMRM) system phantom was also used.</p><p><strong>Field strength/sequence: </strong>3 T, 3D-MRF sequence for bilateral hip joint mapping. Reference sequences include Volume Interpolated Breath-hold Examination (VIBE) for T<sub>1</sub> mapping, and magnetization-prepared fast low-angle shot (TFL) for T<sub>2</sub> and T<sub>1ρ</sub> mapping.</p><p><strong>Assessment: </strong>The signal-to-noise ratio (SNR), repeatability, scan time, and accuracy of T<sub>1</sub>, T<sub>2</sub>, and T<sub>1ρ</sub> maps of 3D-MRF sequence were evaluated on a NIST/ISMRM phantom and human subjects. Differences in the parametric maps between OA and healthy subjects were assessed.</p><p><strong>Statistical tests: </strong>Regression, Bland-Altman, Kruskal-Wallis, and Wilcoxon tests were used to assess for accuracy, repeatability, and subregional variation. The P-value <0.05 indicated statistically significant.</p><p><strong>Results: </strong>A 3D-MRF sequence sensitive to PD, T<sub>1</sub>, T<sub>2</sub>, T<sub>1ρ</sub>, and ∆B<sub>1+</sub> within 15 minutes, achieving high SNR and low test-retest coefficient of variance (T<sub>1</sub>: 3.36%, T<sub>2</sub>: 3.99%, T<sub>1ρ</sub>: 5.93%). Mild hip OA patients, including one with mild OA and FAI, showed elevation of 29.4 ± 9% (T<sub>2</sub>) and 32.4 ± 4.4% (T<sub>1ρ</sub>) in femoral lateral compartment of the hip joint compared to healthy controls.</p><p><strong>Data conclusion: </strong>3D-MRF may be a feasible approach for simultaneous, quantitative mapping of bilateral hip joint cartilage in healthy and mild OA patients.</p><p><strong>Evidence level: </strong>1 TECHNICAL EFFICACY: Stage 1.</p>","PeriodicalId":16140,"journal":{"name":"Journal of Magnetic Resonance Imaging","volume":" ","pages":""},"PeriodicalIF":3.3000,"publicationDate":"2024-12-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Magnetic Resonance Imaging","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1002/jmri.29679","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Three-dimensional MR fingerprinting (3D-MRF) has been increasingly used to assess cartilage degeneration, particularly in the knee joint, by looking into multiple relaxation parameters. A comparable 3D-MRF approach can be adapted to assess cartilage degeneration for the hip joint, with changes to accommodate specific challenges of hip joint imaging.

Purpose: To demonstrate the feasibility and repeatability of 3D-MRF in the bilateral hip jointly we map proton density (PD), T1, T2, T, and ∆B1+ in clinically feasible scan times.

Study type: Prospective.

Subjects: Eight healthy subjects, three patients with mild osteoarthritis (OA), and one of the OA patients had femoral acetabular impingement (FAI). A National Institute of Standards and Technology/International Society for Magnetic Resonance in Medicine (NIST/ISMRM) system phantom was also used.

Field strength/sequence: 3 T, 3D-MRF sequence for bilateral hip joint mapping. Reference sequences include Volume Interpolated Breath-hold Examination (VIBE) for T1 mapping, and magnetization-prepared fast low-angle shot (TFL) for T2 and T mapping.

Assessment: The signal-to-noise ratio (SNR), repeatability, scan time, and accuracy of T1, T2, and T maps of 3D-MRF sequence were evaluated on a NIST/ISMRM phantom and human subjects. Differences in the parametric maps between OA and healthy subjects were assessed.

Statistical tests: Regression, Bland-Altman, Kruskal-Wallis, and Wilcoxon tests were used to assess for accuracy, repeatability, and subregional variation. The P-value <0.05 indicated statistically significant.

Results: A 3D-MRF sequence sensitive to PD, T1, T2, T, and ∆B1+ within 15 minutes, achieving high SNR and low test-retest coefficient of variance (T1: 3.36%, T2: 3.99%, T: 5.93%). Mild hip OA patients, including one with mild OA and FAI, showed elevation of 29.4 ± 9% (T2) and 32.4 ± 4.4% (T) in femoral lateral compartment of the hip joint compared to healthy controls.

Data conclusion: 3D-MRF may be a feasible approach for simultaneous, quantitative mapping of bilateral hip joint cartilage in healthy and mild OA patients.

Evidence level: 1 TECHNICAL EFFICACY: Stage 1.

求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
9.70
自引率
6.80%
发文量
494
审稿时长
2 months
期刊介绍: The Journal of Magnetic Resonance Imaging (JMRI) is an international journal devoted to the timely publication of basic and clinical research, educational and review articles, and other information related to the diagnostic applications of magnetic resonance.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信