Differential phase angle spectrum for liquid detection in functionalized surface roughness polymeric electrode.

Q3 Biochemistry, Genetics and Molecular Biology
Journal of Electrical Bioimpedance Pub Date : 2024-12-23 eCollection Date: 2024-01-01 DOI:10.2478/joeb-1024-0019
John Alexander Gomez-Sanchez, Luciano de Souza Ribero Bueno
{"title":"Differential phase angle spectrum for liquid detection in functionalized surface roughness polymeric electrode.","authors":"John Alexander Gomez-Sanchez, Luciano de Souza Ribero Bueno","doi":"10.2478/joeb-1024-0019","DOIUrl":null,"url":null,"abstract":"<p><p>The conductive polymeric electrodes using 3D printing are an innovative material development with the advantage of the flexibility of integrating isolated polymers with a higher electrical conductivity of carbon-based materials, generating new possibilities in environmental, healthcare, and food monitoring. Based on the morphology, geometric arrangement, and dielectric properties of the composites, the performance of the electrodes is improved. Structural designs are optimized to enhance functionalities such as adhesion, catalytic activity, and the reduction of interface energy. With these concepts, a functionalized carbon-based polymeric electrode was fabricated using 3D printing. The Differential Impedance Spectrum (DIS) was employed to analyze the response of functionalized electrodes to solutions of acetic acid and calcium chloride (<i>CaCl<sub>2</sub></i> ). DIS data extract the differential phase angle and indicate the interactions between the functionalized surface with acetic acid and <i>CaCl<sub>2</sub></i> solutions, showing noticeable peaks in three zones: at lower frequencies (< 10 kHz), medium frequencies range of 10 kHz to 100 kHz, and higher frequencies (> 100 kHz). In the three cases analyzed, the <i>CaCl<sub>2</sub></i> solution presented the highest frequency compared with acetic acid. When the sensor was doubled functionalized, the peaks were shifted between the range of 220 kHz to 280 kHz. A conclusion is that the carbon-based polymer electrode not only reduces manufacturing costs but also enables faster functionalization to detect specific chemical compounds in liquids quickly and portable without the need for higher-level equipment. These electrodes could be applied to make measurements in aqueous media such as ponds, pools, lakes, rivers, and oceans to detect contaminants, as well as in human fluids to recognize metabolites in sweat, urine, saliva, and blood.</p>","PeriodicalId":38125,"journal":{"name":"Journal of Electrical Bioimpedance","volume":"15 1","pages":"162-168"},"PeriodicalIF":0.0000,"publicationDate":"2024-12-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11665877/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Electrical Bioimpedance","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2478/joeb-1024-0019","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"Biochemistry, Genetics and Molecular Biology","Score":null,"Total":0}
引用次数: 0

Abstract

The conductive polymeric electrodes using 3D printing are an innovative material development with the advantage of the flexibility of integrating isolated polymers with a higher electrical conductivity of carbon-based materials, generating new possibilities in environmental, healthcare, and food monitoring. Based on the morphology, geometric arrangement, and dielectric properties of the composites, the performance of the electrodes is improved. Structural designs are optimized to enhance functionalities such as adhesion, catalytic activity, and the reduction of interface energy. With these concepts, a functionalized carbon-based polymeric electrode was fabricated using 3D printing. The Differential Impedance Spectrum (DIS) was employed to analyze the response of functionalized electrodes to solutions of acetic acid and calcium chloride (CaCl2 ). DIS data extract the differential phase angle and indicate the interactions between the functionalized surface with acetic acid and CaCl2 solutions, showing noticeable peaks in three zones: at lower frequencies (< 10 kHz), medium frequencies range of 10 kHz to 100 kHz, and higher frequencies (> 100 kHz). In the three cases analyzed, the CaCl2 solution presented the highest frequency compared with acetic acid. When the sensor was doubled functionalized, the peaks were shifted between the range of 220 kHz to 280 kHz. A conclusion is that the carbon-based polymer electrode not only reduces manufacturing costs but also enables faster functionalization to detect specific chemical compounds in liquids quickly and portable without the need for higher-level equipment. These electrodes could be applied to make measurements in aqueous media such as ponds, pools, lakes, rivers, and oceans to detect contaminants, as well as in human fluids to recognize metabolites in sweat, urine, saliva, and blood.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Electrical Bioimpedance
Journal of Electrical Bioimpedance Engineering-Biomedical Engineering
CiteScore
3.00
自引率
0.00%
发文量
8
审稿时长
17 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信