Inductively Coupled Plasma Mass Spectrometry Performance for the Measurement of Key Serum Minerals: A Comparative Study With Standard Quantification Methods.

IF 2.6 4区 医学 Q2 MEDICAL LABORATORY TECHNOLOGY
Kosuke Kojo, Tomoko Oguri, Takazo Tanaka, Atsushi Ikeda, Takuya Shimizu, Shunsuke Fujimoto, Ayumi Nakazono, Yoshiyuki Nagumo, Shuya Kandori, Hiromitsu Negoro, Hiroyuki Nishiyama
{"title":"Inductively Coupled Plasma Mass Spectrometry Performance for the Measurement of Key Serum Minerals: A Comparative Study With Standard Quantification Methods.","authors":"Kosuke Kojo, Tomoko Oguri, Takazo Tanaka, Atsushi Ikeda, Takuya Shimizu, Shunsuke Fujimoto, Ayumi Nakazono, Yoshiyuki Nagumo, Shuya Kandori, Hiromitsu Negoro, Hiroyuki Nishiyama","doi":"10.1002/jcla.25140","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Inductively coupled plasma mass spectrometry (ICP-MS) is widely used for the accurate measurement of minerals. However, its application to serum essential mineral measurement has not been fully evaluated. The present study aimed to assess the performance of ICP-MS for serum minerals by comparing its measurements to those obtained using standard quantification methods.</p><p><strong>Methods: </strong>Cross-sectional data were collected from 282 participants from a single facility in Japan. Serum concentrations of eight key minerals, namely sodium, potassium, calcium, phosphorus, magnesium, iron, zinc, and copper, measured via ICP-MS and standard methods were compared using Passing-Bablok regression and Bland-Altman plots.</p><p><strong>Results: </strong>All minerals, except phosphorus, exhibited good agreement with standard methods, with more stable regression coefficients observed for minerals with greater interindividual variability. After systematically filtering outliers, the mean relative errors were approximately -3% for sodium, potassium, calcium, and magnesium; +5% for iron; 0% for zinc; and -19% for copper. The outliers for iron were primarily due to mild hemolysis, whereas those for zinc were largely attributed to nonhemolysis factors. For phosphorus, the serum total phosphorus concentration measured using ICP-MS was approximately 3.5 times higher than the serum inorganic phosphorus concentration measured using standard methods, with a weak correlation observed between the two methods.</p><p><strong>Conclusion: </strong>This study provides a practical foundation for future research. Understanding ICP-MS characteristics will facilitate the development of new approaches in clinical diagnostics.</p>","PeriodicalId":15509,"journal":{"name":"Journal of Clinical Laboratory Analysis","volume":" ","pages":"e25140"},"PeriodicalIF":2.6000,"publicationDate":"2024-12-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Clinical Laboratory Analysis","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1002/jcla.25140","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MEDICAL LABORATORY TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Inductively coupled plasma mass spectrometry (ICP-MS) is widely used for the accurate measurement of minerals. However, its application to serum essential mineral measurement has not been fully evaluated. The present study aimed to assess the performance of ICP-MS for serum minerals by comparing its measurements to those obtained using standard quantification methods.

Methods: Cross-sectional data were collected from 282 participants from a single facility in Japan. Serum concentrations of eight key minerals, namely sodium, potassium, calcium, phosphorus, magnesium, iron, zinc, and copper, measured via ICP-MS and standard methods were compared using Passing-Bablok regression and Bland-Altman plots.

Results: All minerals, except phosphorus, exhibited good agreement with standard methods, with more stable regression coefficients observed for minerals with greater interindividual variability. After systematically filtering outliers, the mean relative errors were approximately -3% for sodium, potassium, calcium, and magnesium; +5% for iron; 0% for zinc; and -19% for copper. The outliers for iron were primarily due to mild hemolysis, whereas those for zinc were largely attributed to nonhemolysis factors. For phosphorus, the serum total phosphorus concentration measured using ICP-MS was approximately 3.5 times higher than the serum inorganic phosphorus concentration measured using standard methods, with a weak correlation observed between the two methods.

Conclusion: This study provides a practical foundation for future research. Understanding ICP-MS characteristics will facilitate the development of new approaches in clinical diagnostics.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Clinical Laboratory Analysis
Journal of Clinical Laboratory Analysis 医学-医学实验技术
CiteScore
5.60
自引率
7.40%
发文量
584
审稿时长
6-12 weeks
期刊介绍: Journal of Clinical Laboratory Analysis publishes original articles on newly developing modes of technology and laboratory assays, with emphasis on their application in current and future clinical laboratory testing. This includes reports from the following fields: immunochemistry and toxicology, hematology and hematopathology, immunopathology, molecular diagnostics, microbiology, genetic testing, immunohematology, and clinical chemistry.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信