R290-Hydrofluoroolefin based low global warming potential refrigerant mixtures for room air conditioner: An energy, exergy, and environmental (3E) analysis.

IF 5.8 3区 环境科学与生态学 0 ENVIRONMENTAL SCIENCES
Saji Raveendran Padmavathy, Joseph Sekhar Santhappan, Rajendran Prabakaran, Sung Chul Kim, Murugan Paradesi Chockalingam, Ahmed Said Ahmed Al-Shahri
{"title":"R290-Hydrofluoroolefin based low global warming potential refrigerant mixtures for room air conditioner: An energy, exergy, and environmental (3E) analysis.","authors":"Saji Raveendran Padmavathy, Joseph Sekhar Santhappan, Rajendran Prabakaran, Sung Chul Kim, Murugan Paradesi Chockalingam, Ahmed Said Ahmed Al-Shahri","doi":"10.1007/s11356-024-35656-x","DOIUrl":null,"url":null,"abstract":"<p><p>Among the numerous residential appliances, window or split air conditioners are the most prevalent. The hydrochlorofluorocarbon and hydrofluorocarbon refrigerants used in those systems are causing a serious threat to the environment. In this study, R290-hydrofluoroolefin (HFO) mixtures are proposed as replacements for high-GWP substances (R410A and R22) in window air conditioning (WAC) units. Low-flammability alternatives like R290-R1234yf (50:50 and 60:40 by mass) and R290-R1234ze(E) (50:50 and 60:40 by mass) mixtures were considered promising refrigerants for this study. Using the REFPROP 10.0 refrigerant database and MATLAB-based mathematical modelling, the energy and exergy performance of a WAC unit with proposed and existing refrigerants was investigated. The results demonstrated that R290-HFO mixers performed well, with coefficients of performance that were 5.1-11.9% and 10.8-17.0% higher than those of R22 and R410A, respectively. In a similar fashion, the exergy efficiency of the WAC system increased by 3.1% to 6.2%, with reductions in total exergy degradation and power consumption of 7.1% to 12.2% and 5.1% to 10.1%, respectively. An assessment of the total equivalent warming impact revealed that the use of R290-HFO compounds results in CO<sub>2</sub> emissions that are between 7.1 and 12.2% less than those of R22. Mini or microchannel heat exchangers for conventional evaporators and condensers can further decrease the predicted refrigerant change quantity for these mixtures, keeping it well below the IEC 60335-2-89 limit for flammable refrigerants.</p>","PeriodicalId":545,"journal":{"name":"Environmental Science and Pollution Research","volume":" ","pages":""},"PeriodicalIF":5.8000,"publicationDate":"2024-12-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Environmental Science and Pollution Research","FirstCategoryId":"93","ListUrlMain":"https://doi.org/10.1007/s11356-024-35656-x","RegionNum":3,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"0","JCRName":"ENVIRONMENTAL SCIENCES","Score":null,"Total":0}
引用次数: 0

Abstract

Among the numerous residential appliances, window or split air conditioners are the most prevalent. The hydrochlorofluorocarbon and hydrofluorocarbon refrigerants used in those systems are causing a serious threat to the environment. In this study, R290-hydrofluoroolefin (HFO) mixtures are proposed as replacements for high-GWP substances (R410A and R22) in window air conditioning (WAC) units. Low-flammability alternatives like R290-R1234yf (50:50 and 60:40 by mass) and R290-R1234ze(E) (50:50 and 60:40 by mass) mixtures were considered promising refrigerants for this study. Using the REFPROP 10.0 refrigerant database and MATLAB-based mathematical modelling, the energy and exergy performance of a WAC unit with proposed and existing refrigerants was investigated. The results demonstrated that R290-HFO mixers performed well, with coefficients of performance that were 5.1-11.9% and 10.8-17.0% higher than those of R22 and R410A, respectively. In a similar fashion, the exergy efficiency of the WAC system increased by 3.1% to 6.2%, with reductions in total exergy degradation and power consumption of 7.1% to 12.2% and 5.1% to 10.1%, respectively. An assessment of the total equivalent warming impact revealed that the use of R290-HFO compounds results in CO2 emissions that are between 7.1 and 12.2% less than those of R22. Mini or microchannel heat exchangers for conventional evaporators and condensers can further decrease the predicted refrigerant change quantity for these mixtures, keeping it well below the IEC 60335-2-89 limit for flammable refrigerants.

求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
8.70
自引率
17.20%
发文量
6549
审稿时长
3.8 months
期刊介绍: Environmental Science and Pollution Research (ESPR) serves the international community in all areas of Environmental Science and related subjects with emphasis on chemical compounds. This includes: - Terrestrial Biology and Ecology - Aquatic Biology and Ecology - Atmospheric Chemistry - Environmental Microbiology/Biobased Energy Sources - Phytoremediation and Ecosystem Restoration - Environmental Analyses and Monitoring - Assessment of Risks and Interactions of Pollutants in the Environment - Conservation Biology and Sustainable Agriculture - Impact of Chemicals/Pollutants on Human and Animal Health It reports from a broad interdisciplinary outlook.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信