Patient-Reported Outcomes of Orthodontic Treatment for Mild Crowding With Modified Aligner Appliance With Nickel-Titanium Springs: A Prospective Cohort Study.

IF 1 Q3 MEDICINE, GENERAL & INTERNAL
Cureus Pub Date : 2024-12-22 eCollection Date: 2024-12-01 DOI:10.7759/cureus.76179
Ziad Mohamad Alhafi, Mohammad Y Hajeer, Ahmad S Burhan, Youssef Latifeh, Mowaffak A Ajaj, Alaa Oudah Ali Almusawi, Ahmad Salim Zakaria
{"title":"Patient-Reported Outcomes of Orthodontic Treatment for Mild Crowding With Modified Aligner Appliance With Nickel-Titanium Springs: A Prospective Cohort Study.","authors":"Ziad Mohamad Alhafi, Mohammad Y Hajeer, Ahmad S Burhan, Youssef Latifeh, Mowaffak A Ajaj, Alaa Oudah Ali Almusawi, Ahmad Salim Zakaria","doi":"10.7759/cureus.76179","DOIUrl":null,"url":null,"abstract":"<p><p>Background and objectives A modified aligner appliance with nickel-titanium springs (MAA) is a relatively new appliance that has not received extensive attention in orthodontics. This study evaluated the patient-reported outcomes when orthodontic treatment was provided using a modified aligner appliance to treat mild lower incisor crowding. Materials and methods This prospective cohort study consisted of 42 patients (11 males and 31 females; mean age 21.69 ± 2.56 years) with mild crowding. Twenty-one patients were treated using a modified aligner with nickel-titanium springs, while the remaining patients were treated with a conventional fixed orthodontic appliance (FA). Patient responses regarding pain, discomfort, and difficulty in chewing, swallowing, and speaking were recorded using a visual analog scale (VAS) at six assessment times: 24 hours (T1), two days (T2), three days (T3), two weeks (T4), one month (T5), and two months (T6) after appliance application. Results The mean perceived pain and discomfort levels were generally lower in the traditional fixed appliance (FA) group than the modified aligner appliance with nickel-titanium springs group at most assessment times. However, no statistically significant differences were found between the two groups. Chewing difficulty levels were similar between the two groups with no substantial differences. Swallowing and speech difficulty were significantly higher in the MAA group compared to the FA group during the first two days of treatment (P < 0.008). Conclusions Patients using both types of orthodontic appliances experienced temporary discomfort, including pain and difficulty chewing. While the modified aligners appliance with nickel-titanium springs caused additional challenges with swallowing and speaking, these issues were resolved over time, allowing patients to adjust to the treatment.</p>","PeriodicalId":93960,"journal":{"name":"Cureus","volume":"16 12","pages":"e76179"},"PeriodicalIF":1.0000,"publicationDate":"2024-12-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11663397/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cureus","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.7759/cureus.76179","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/12/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
引用次数: 0

Abstract

Background and objectives A modified aligner appliance with nickel-titanium springs (MAA) is a relatively new appliance that has not received extensive attention in orthodontics. This study evaluated the patient-reported outcomes when orthodontic treatment was provided using a modified aligner appliance to treat mild lower incisor crowding. Materials and methods This prospective cohort study consisted of 42 patients (11 males and 31 females; mean age 21.69 ± 2.56 years) with mild crowding. Twenty-one patients were treated using a modified aligner with nickel-titanium springs, while the remaining patients were treated with a conventional fixed orthodontic appliance (FA). Patient responses regarding pain, discomfort, and difficulty in chewing, swallowing, and speaking were recorded using a visual analog scale (VAS) at six assessment times: 24 hours (T1), two days (T2), three days (T3), two weeks (T4), one month (T5), and two months (T6) after appliance application. Results The mean perceived pain and discomfort levels were generally lower in the traditional fixed appliance (FA) group than the modified aligner appliance with nickel-titanium springs group at most assessment times. However, no statistically significant differences were found between the two groups. Chewing difficulty levels were similar between the two groups with no substantial differences. Swallowing and speech difficulty were significantly higher in the MAA group compared to the FA group during the first two days of treatment (P < 0.008). Conclusions Patients using both types of orthodontic appliances experienced temporary discomfort, including pain and difficulty chewing. While the modified aligners appliance with nickel-titanium springs caused additional challenges with swallowing and speaking, these issues were resolved over time, allowing patients to adjust to the treatment.

求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信