Intragastric balloon adverse events: a comprehensive MAUDE database review.

Q3 Medicine
Baylor University Medical Center Proceedings Pub Date : 2024-10-10 eCollection Date: 2025-01-01 DOI:10.1080/08998280.2024.2406710
Islam Mohamed, Jagadish Koyi, Husam Abu Suilik, Hazem Abosheiashaa, Fouad Jaber, Syed Hamaad Rahman, Dushyant Singh Dahiya, Ahmed Telbany, Omar T Ahmed, Yusuke Hashimoto
{"title":"Intragastric balloon adverse events: a comprehensive MAUDE database review.","authors":"Islam Mohamed, Jagadish Koyi, Husam Abu Suilik, Hazem Abosheiashaa, Fouad Jaber, Syed Hamaad Rahman, Dushyant Singh Dahiya, Ahmed Telbany, Omar T Ahmed, Yusuke Hashimoto","doi":"10.1080/08998280.2024.2406710","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Endoscopic bariatric interventions are viable alternatives to traditional weight loss surgeries for patients with a body mass index between 30 and 40 kg/m<sup>2</sup>. While studies have explored the impact of intragastric balloons on obesity and weight reduction, comprehensive data on real-world device-related complications and failures are limited. This study aimed to investigate mechanical failures leading to patient adverse events reported to the US Food and Drug Administration.</p><p><strong>Methods: </strong>A retrospective analysis using the Manufacturer and User Facility Device Experience (MAUDE) database examined device-related events and patient outcomes associated with various intragastric balloons from July 2017 to October 2023. Data analysis was performed using SPSS software to assess the reported events and their associations with specific types of intragastric balloons.</p><p><strong>Results: </strong>Our review included 1393 cases, revealing 1758 device malfunctions and 1760 patient complications. Deflation problems (25.31%) and balloon leakage or rupture (21.90%) were the most common device-related complications. Patient complications were primarily linked to the Orbera balloon, with implant failure (24.30%), abdominal pain (21.92%), and vomiting (21.26%) as leading adverse events.</p><p><strong>Conclusion: </strong>Our findings highlight the need for continuous surveillance, rigorous monitoring, and enhanced safety protocols for intragastric balloons.</p>","PeriodicalId":8828,"journal":{"name":"Baylor University Medical Center Proceedings","volume":"38 1","pages":"63-68"},"PeriodicalIF":0.0000,"publicationDate":"2024-10-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11657097/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Baylor University Medical Center Proceedings","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/08998280.2024.2406710","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Endoscopic bariatric interventions are viable alternatives to traditional weight loss surgeries for patients with a body mass index between 30 and 40 kg/m2. While studies have explored the impact of intragastric balloons on obesity and weight reduction, comprehensive data on real-world device-related complications and failures are limited. This study aimed to investigate mechanical failures leading to patient adverse events reported to the US Food and Drug Administration.

Methods: A retrospective analysis using the Manufacturer and User Facility Device Experience (MAUDE) database examined device-related events and patient outcomes associated with various intragastric balloons from July 2017 to October 2023. Data analysis was performed using SPSS software to assess the reported events and their associations with specific types of intragastric balloons.

Results: Our review included 1393 cases, revealing 1758 device malfunctions and 1760 patient complications. Deflation problems (25.31%) and balloon leakage or rupture (21.90%) were the most common device-related complications. Patient complications were primarily linked to the Orbera balloon, with implant failure (24.30%), abdominal pain (21.92%), and vomiting (21.26%) as leading adverse events.

Conclusion: Our findings highlight the need for continuous surveillance, rigorous monitoring, and enhanced safety protocols for intragastric balloons.

求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
1.30
自引率
0.00%
发文量
245
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信