Development and clinical validation of photochemical biosensors for monitoring hemoglobin, blood lipids and uric acid in plateau areas.

IF 2.7 3区 化学 Q2 CHEMISTRY, ANALYTICAL
Bo Yu, Qiuping Li, Wei Zhang, Xiaoyan Xiang, Danzeng Quda, Gasong Zhuoga, Qiong Huang, Jie Cheng, Jinhong Guo, Zhijuan Liu, Li Shi
{"title":"Development and clinical validation of photochemical biosensors for monitoring hemoglobin, blood lipids and uric acid in plateau areas.","authors":"Bo Yu, Qiuping Li, Wei Zhang, Xiaoyan Xiang, Danzeng Quda, Gasong Zhuoga, Qiong Huang, Jie Cheng, Jinhong Guo, Zhijuan Liu, Li Shi","doi":"10.1039/d4ay01737d","DOIUrl":null,"url":null,"abstract":"<p><p>High-altitude regions are prone to plateau erythrocytosis due to unique geo-climatic conditions such as low oxygen, high altitude, and low temperatures, with significantly higher incidences of hyperlipidemia and hyperuricemia compared to lowland areas. However, the extreme environmental conditions at high altitudes and the elevated hematocrit levels in blood samples from these populations present significant challenges to the applicability of existing point-of-care testing (POCT) devices. This study describes the development, early clinical validation, and potential clinical impact of three portable, paper-based photochemical biosensing platforms specifically designed for use at high altitudes to monitor hemoglobin, lipids, and uric acid in blood samples. To systematically evaluate the performance of these sensors, 154 fresh venous blood samples from three distinct altitudes were tested and compared with a reference measurement system, alongside an extensive evaluation for the first time of the suitability of various commercially available POCT devices, including these platforms, for use in high-altitude environments. The results demonstrated that the accuracy and concordance between the developed platforms and the reference system were consistently above 95%. Additionally, concordance remained above 95% when the same samples were tested at varying altitudes (4500 m to 3650 m and 4800 m to 3650 m). All of this indicates that the sensing platform provides high accuracy and reliability for testing in high-altitude environments. It holds promise for broader application in the screening and management of chronic diseases in high-altitude and other extreme environments, and for advancing the use of bedside testing technology in resource-limited settings.</p>","PeriodicalId":64,"journal":{"name":"Analytical Methods","volume":" ","pages":""},"PeriodicalIF":2.7000,"publicationDate":"2024-12-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical Methods","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1039/d4ay01737d","RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

High-altitude regions are prone to plateau erythrocytosis due to unique geo-climatic conditions such as low oxygen, high altitude, and low temperatures, with significantly higher incidences of hyperlipidemia and hyperuricemia compared to lowland areas. However, the extreme environmental conditions at high altitudes and the elevated hematocrit levels in blood samples from these populations present significant challenges to the applicability of existing point-of-care testing (POCT) devices. This study describes the development, early clinical validation, and potential clinical impact of three portable, paper-based photochemical biosensing platforms specifically designed for use at high altitudes to monitor hemoglobin, lipids, and uric acid in blood samples. To systematically evaluate the performance of these sensors, 154 fresh venous blood samples from three distinct altitudes were tested and compared with a reference measurement system, alongside an extensive evaluation for the first time of the suitability of various commercially available POCT devices, including these platforms, for use in high-altitude environments. The results demonstrated that the accuracy and concordance between the developed platforms and the reference system were consistently above 95%. Additionally, concordance remained above 95% when the same samples were tested at varying altitudes (4500 m to 3650 m and 4800 m to 3650 m). All of this indicates that the sensing platform provides high accuracy and reliability for testing in high-altitude environments. It holds promise for broader application in the screening and management of chronic diseases in high-altitude and other extreme environments, and for advancing the use of bedside testing technology in resource-limited settings.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Analytical Methods
Analytical Methods CHEMISTRY, ANALYTICAL-FOOD SCIENCE & TECHNOLOGY
CiteScore
5.10
自引率
3.20%
发文量
569
审稿时长
1.8 months
期刊介绍: Early applied demonstrations of new analytical methods with clear societal impact
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信