Charging and Discharging of Poly(m-aminophenylboronic Acid) Doped with Phytic Acid for Enzyme-Free Real-Time Monitoring of Human Sweat Lactate.

IF 3.7 3区 化学 Q2 CHEMISTRY, MULTIDISCIPLINARY
ACS Omega Pub Date : 2024-12-09 eCollection Date: 2024-12-17 DOI:10.1021/acsomega.4c06671
Ryujiro Kishi, Shoichi Nishitani, Hiroyuki Kudo, Toshiya Sakata
{"title":"Charging and Discharging of Poly(<i>m</i>-aminophenylboronic Acid) Doped with Phytic Acid for Enzyme-Free Real-Time Monitoring of Human Sweat Lactate.","authors":"Ryujiro Kishi, Shoichi Nishitani, Hiroyuki Kudo, Toshiya Sakata","doi":"10.1021/acsomega.4c06671","DOIUrl":null,"url":null,"abstract":"<p><p>In this study, we realized a real-time and enzyme-free measurement of lactate in sweat in the same way as an enzyme-based amperometric method. A conductive polymer, which is based on polyaniline (PANI), was strongly coated on a glassy carbon electrode as a poly <i>m</i>-aminophenylboronic acid (PANI-PBA) membrane by drop-casting, which is a convenient method, owing to adhesive phytic acid (PA) molecules with negative charges included as a dopant. This polymer membrane had a functional structure with PBA in the PANI main chain, which expectedly induced electrical charges upon diol binding to lactate, owing to the formation of deprotonated boronate esters with negative charges. This indicates that PBA served as the self-dopant and as the site of binding to lactate. On the basis of the fundamental electrochemical characteristics such as the membrane resistance, the change in the current density of the PA-doped PANI-PBA electrode was quantitatively monitored with the change in lactate concentration from 1 to 300 mM under acidic conditions in real time, considering pH and interfering substances in sweat. Moreover, the sweat lactate concentration was determined to be ca. 60 mM using the PA-doped PANI-PBA electrode in a microfluidic system in measurements using sweat samples collected during exercise load. A change in current density induced a change in the density of charges in the capacitive PA-doped PANI-PBA membrane. This means that the detection mechanism for the change in the lactate concentration in sweat was based on repeated charging and discharging in the PA-doped PANI-PBA electrode.</p>","PeriodicalId":22,"journal":{"name":"ACS Omega","volume":"9 50","pages":"49368-49376"},"PeriodicalIF":3.7000,"publicationDate":"2024-12-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11656369/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Omega","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1021/acsomega.4c06671","RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/12/17 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

Abstract

In this study, we realized a real-time and enzyme-free measurement of lactate in sweat in the same way as an enzyme-based amperometric method. A conductive polymer, which is based on polyaniline (PANI), was strongly coated on a glassy carbon electrode as a poly m-aminophenylboronic acid (PANI-PBA) membrane by drop-casting, which is a convenient method, owing to adhesive phytic acid (PA) molecules with negative charges included as a dopant. This polymer membrane had a functional structure with PBA in the PANI main chain, which expectedly induced electrical charges upon diol binding to lactate, owing to the formation of deprotonated boronate esters with negative charges. This indicates that PBA served as the self-dopant and as the site of binding to lactate. On the basis of the fundamental electrochemical characteristics such as the membrane resistance, the change in the current density of the PA-doped PANI-PBA electrode was quantitatively monitored with the change in lactate concentration from 1 to 300 mM under acidic conditions in real time, considering pH and interfering substances in sweat. Moreover, the sweat lactate concentration was determined to be ca. 60 mM using the PA-doped PANI-PBA electrode in a microfluidic system in measurements using sweat samples collected during exercise load. A change in current density induced a change in the density of charges in the capacitive PA-doped PANI-PBA membrane. This means that the detection mechanism for the change in the lactate concentration in sweat was based on repeated charging and discharging in the PA-doped PANI-PBA electrode.

求助全文
约1分钟内获得全文 求助全文
来源期刊
ACS Omega
ACS Omega Chemical Engineering-General Chemical Engineering
CiteScore
6.60
自引率
4.90%
发文量
3945
审稿时长
2.4 months
期刊介绍: ACS Omega is an open-access global publication for scientific articles that describe new findings in chemistry and interfacing areas of science, without any perceived evaluation of immediate impact.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信