The effect of micro-vessel viscosity on the resonance response of a two-microbubble system.

IF 3.8 2区 物理与天体物理 Q1 ACOUSTICS
Hossein Yusefi, Brandon Helfield
{"title":"The effect of micro-vessel viscosity on the resonance response of a two-microbubble system.","authors":"Hossein Yusefi, Brandon Helfield","doi":"10.1016/j.ultras.2024.107558","DOIUrl":null,"url":null,"abstract":"<p><p>Clinical ultrasound contrast agent microbubbles remain intravascular and are between 1-8 µm in diameter, with a volume-weighted mean size of 2-3 µm. Despite their worldwide clinical utility as a diagnostic contrast agent, and their continued and ongoing success as a local therapeutic vector, the fundamental interplay between microbubbles - including bubble-bubble interaction and the effects of a neighboring viscoelastic vessel wall, remain poorly understood. In this work, we developed a finite element model to study the physics of the complex system of two different-sized bubbles (2 and 3 µm in diameter) confined within a viscoelastic vessel from a resonance response perspective (3-12 MHz). Here, we focus on the effect of micro-vessel wall viscosity on the resulting vibrational activity of the two-bubble system. The larger bubble (3 µm) was not influenced by its smaller companion bubble, and we observed a significant dampening effect across all transmit frequencies when confined within the vessel of increasing viscosity, an expected result. However, the smaller bubble (2 µm) was highly influenced by its larger neighboring bubble, including the induction of a strong low-frequency resonant response - resulting in transmit frequency windows in which its response in a lightly damped vessel far exceeded its vibration amplitude when unconfined. Further, micro-vessel wall dynamics closely mimic the frequency-dependence of the adjacent bubbles. Our findings imply that for a system of multi-bubbles within a viscoelastic vessel, the larger bubble physics dominates the system by inducing the smaller bubble and the vessel wall to follow its vibration - an effect that can be amplified within a lightly damped vessel. These findings have important implications for contrast-enhanced ultrasound imaging and therapeutic applications.</p>","PeriodicalId":23522,"journal":{"name":"Ultrasonics","volume":"148 ","pages":"107558"},"PeriodicalIF":3.8000,"publicationDate":"2024-12-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ultrasonics","FirstCategoryId":"101","ListUrlMain":"https://doi.org/10.1016/j.ultras.2024.107558","RegionNum":2,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ACOUSTICS","Score":null,"Total":0}
引用次数: 0

Abstract

Clinical ultrasound contrast agent microbubbles remain intravascular and are between 1-8 µm in diameter, with a volume-weighted mean size of 2-3 µm. Despite their worldwide clinical utility as a diagnostic contrast agent, and their continued and ongoing success as a local therapeutic vector, the fundamental interplay between microbubbles - including bubble-bubble interaction and the effects of a neighboring viscoelastic vessel wall, remain poorly understood. In this work, we developed a finite element model to study the physics of the complex system of two different-sized bubbles (2 and 3 µm in diameter) confined within a viscoelastic vessel from a resonance response perspective (3-12 MHz). Here, we focus on the effect of micro-vessel wall viscosity on the resulting vibrational activity of the two-bubble system. The larger bubble (3 µm) was not influenced by its smaller companion bubble, and we observed a significant dampening effect across all transmit frequencies when confined within the vessel of increasing viscosity, an expected result. However, the smaller bubble (2 µm) was highly influenced by its larger neighboring bubble, including the induction of a strong low-frequency resonant response - resulting in transmit frequency windows in which its response in a lightly damped vessel far exceeded its vibration amplitude when unconfined. Further, micro-vessel wall dynamics closely mimic the frequency-dependence of the adjacent bubbles. Our findings imply that for a system of multi-bubbles within a viscoelastic vessel, the larger bubble physics dominates the system by inducing the smaller bubble and the vessel wall to follow its vibration - an effect that can be amplified within a lightly damped vessel. These findings have important implications for contrast-enhanced ultrasound imaging and therapeutic applications.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Ultrasonics
Ultrasonics 医学-核医学
CiteScore
7.60
自引率
19.00%
发文量
186
审稿时长
3.9 months
期刊介绍: Ultrasonics is the only internationally established journal which covers the entire field of ultrasound research and technology and all its many applications. Ultrasonics contains a variety of sections to keep readers fully informed and up-to-date on the whole spectrum of research and development throughout the world. Ultrasonics publishes papers of exceptional quality and of relevance to both academia and industry. Manuscripts in which ultrasonics is a central issue and not simply an incidental tool or minor issue, are welcomed. As well as top quality original research papers and review articles by world renowned experts, Ultrasonics also regularly features short communications, a calendar of forthcoming events and special issues dedicated to topical subjects.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信