Assessment of sleep quality using cardiopulmonary coupling and its predictive value for delirium in ICU patients.

IF 3.8 2区 医学 Q1 CLINICAL NEUROLOGY
Chunyan Liu, Xiaowei Ji, Jianhong Lu, Lei Zhong, Jie Hu, Yongbin Wang, Qing Zhou, Bo Xie
{"title":"Assessment of sleep quality using cardiopulmonary coupling and its predictive value for delirium in ICU patients.","authors":"Chunyan Liu, Xiaowei Ji, Jianhong Lu, Lei Zhong, Jie Hu, Yongbin Wang, Qing Zhou, Bo Xie","doi":"10.1016/j.sleep.2024.12.020","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To assess sleep quality in intensive care unit (ICU) patients using cardiopulmonary coupling (CPC) analysis and explore its predictive value for delirium.</p><p><strong>Method: </strong>ICU patients (n = 135) were divided into the delirium group (n = 44) and control group (n = 91) based on the Confusion Assessment Method for the Intensive Care Unit (CAM-ICU). CPC analysis was used to evaluate the sleep quality of all participants.</p><p><strong>Result: </strong>Intergroup comparisons showed that total sleep time, stable sleep time, and sleep efficiency were significantly lower in the delirium group than in the control group, whereas unstable sleep time, rapid eye movement sleep time, wake-up time, stable sleep latency, and apnea-hypopnea index (AHI) were significantly higher in the delirium group than in the control group. Logistic regression analysis showed that advanced age and AHI were risk factors for delirium, whereas stable sleep time was a protective factor for delirium. Receiver operating characteristic (ROC) analysis showed that stable sleep time and stable sleep latency had a certain predictive value for delirium; the area under the ROC curve (AUC) for stable sleep time was higher (0.888 vs. 0.704). The cut-off value for stable sleep time was 0.65 h, with a sensitivity of 84.1 % and specificity of 81.3 %.</p><p><strong>Conclusion: </strong>ICU patients with delirium have poorer sleep quality than patients without delirium. Stable sleep time derived from the CPC has a high predictive value for delirium and may serve as an objective indicator for its diagnosis.</p>","PeriodicalId":21874,"journal":{"name":"Sleep medicine","volume":"126 ","pages":"222-227"},"PeriodicalIF":3.8000,"publicationDate":"2024-12-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Sleep medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.sleep.2024.12.020","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: To assess sleep quality in intensive care unit (ICU) patients using cardiopulmonary coupling (CPC) analysis and explore its predictive value for delirium.

Method: ICU patients (n = 135) were divided into the delirium group (n = 44) and control group (n = 91) based on the Confusion Assessment Method for the Intensive Care Unit (CAM-ICU). CPC analysis was used to evaluate the sleep quality of all participants.

Result: Intergroup comparisons showed that total sleep time, stable sleep time, and sleep efficiency were significantly lower in the delirium group than in the control group, whereas unstable sleep time, rapid eye movement sleep time, wake-up time, stable sleep latency, and apnea-hypopnea index (AHI) were significantly higher in the delirium group than in the control group. Logistic regression analysis showed that advanced age and AHI were risk factors for delirium, whereas stable sleep time was a protective factor for delirium. Receiver operating characteristic (ROC) analysis showed that stable sleep time and stable sleep latency had a certain predictive value for delirium; the area under the ROC curve (AUC) for stable sleep time was higher (0.888 vs. 0.704). The cut-off value for stable sleep time was 0.65 h, with a sensitivity of 84.1 % and specificity of 81.3 %.

Conclusion: ICU patients with delirium have poorer sleep quality than patients without delirium. Stable sleep time derived from the CPC has a high predictive value for delirium and may serve as an objective indicator for its diagnosis.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Sleep medicine
Sleep medicine 医学-临床神经学
CiteScore
8.40
自引率
6.20%
发文量
1060
审稿时长
49 days
期刊介绍: Sleep Medicine aims to be a journal no one involved in clinical sleep medicine can do without. A journal primarily focussing on the human aspects of sleep, integrating the various disciplines that are involved in sleep medicine: neurology, clinical neurophysiology, internal medicine (particularly pulmonology and cardiology), psychology, psychiatry, sleep technology, pediatrics, neurosurgery, otorhinolaryngology, and dentistry. The journal publishes the following types of articles: Reviews (also intended as a way to bridge the gap between basic sleep research and clinical relevance); Original Research Articles; Full-length articles; Brief communications; Controversies; Case reports; Letters to the Editor; Journal search and commentaries; Book reviews; Meeting announcements; Listing of relevant organisations plus web sites.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信