Yan Li, Jun Li, Guiyuan Li, Runbin Cao, Xinjie Zeng, Ning Tong
{"title":"High-speed main protection for multiterminal LCC-MMC-UHVDC based on initial wave process comparison","authors":"Yan Li, Jun Li, Guiyuan Li, Runbin Cao, Xinjie Zeng, Ning Tong","doi":"10.1049/gtd2.13301","DOIUrl":null,"url":null,"abstract":"<p>The multiterminal LCC-MMC-UHVDC, which employs an LCC on the rectifier side and multiple FHMMCs on the inverter side, has emerged as a cutting-edge technology. Nevertheless, distinct disparities in their protection requirements compared to those of conventional DC grids pose notable challenges in attaining the desired attributes. This paper first derives variation patterns in the time domain of initial waves under different fault conditions. By utilizing the theoretically calculated rate-of-change waveform for the backward current traveling wave in an external fault scenario as a reference, a main protection relay grounded in initial wave process comparison is proposed. This approach capitalizes on the disparity observed in internal faults with the theoretical waveform. To mitigate maloperations stemming from the employment of a non-directional start-up criterion in reverse fault scenarios, subtle noise patterns, mimicking the theoretical waveforms, are infused into the actual waveforms. This approach averts maloperations in reverse faults and obviates the need for added delays associated with directional start-up criteria, thereby enhancing both speed and security. Case studies demonstrate that the proposed protection offers sufficient selectivity and a resistive tolerance of 600 ohms and boasts a speed of 0.2 ms, satisfying the requirements of 800 kV UHVDC systems.</p>","PeriodicalId":13261,"journal":{"name":"Iet Generation Transmission & Distribution","volume":"18 24","pages":"4302-4327"},"PeriodicalIF":2.0000,"publicationDate":"2024-10-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1049/gtd2.13301","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Iet Generation Transmission & Distribution","FirstCategoryId":"5","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1049/gtd2.13301","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0
Abstract
The multiterminal LCC-MMC-UHVDC, which employs an LCC on the rectifier side and multiple FHMMCs on the inverter side, has emerged as a cutting-edge technology. Nevertheless, distinct disparities in their protection requirements compared to those of conventional DC grids pose notable challenges in attaining the desired attributes. This paper first derives variation patterns in the time domain of initial waves under different fault conditions. By utilizing the theoretically calculated rate-of-change waveform for the backward current traveling wave in an external fault scenario as a reference, a main protection relay grounded in initial wave process comparison is proposed. This approach capitalizes on the disparity observed in internal faults with the theoretical waveform. To mitigate maloperations stemming from the employment of a non-directional start-up criterion in reverse fault scenarios, subtle noise patterns, mimicking the theoretical waveforms, are infused into the actual waveforms. This approach averts maloperations in reverse faults and obviates the need for added delays associated with directional start-up criteria, thereby enhancing both speed and security. Case studies demonstrate that the proposed protection offers sufficient selectivity and a resistive tolerance of 600 ohms and boasts a speed of 0.2 ms, satisfying the requirements of 800 kV UHVDC systems.
期刊介绍:
IET Generation, Transmission & Distribution is intended as a forum for the publication and discussion of current practice and future developments in electric power generation, transmission and distribution. Practical papers in which examples of good present practice can be described and disseminated are particularly sought. Papers of high technical merit relying on mathematical arguments and computation will be considered, but authors are asked to relegate, as far as possible, the details of analysis to an appendix.
The scope of IET Generation, Transmission & Distribution includes the following:
Design of transmission and distribution systems
Operation and control of power generation
Power system management, planning and economics
Power system operation, protection and control
Power system measurement and modelling
Computer applications and computational intelligence in power flexible AC or DC transmission systems
Special Issues. Current Call for papers:
Next Generation of Synchrophasor-based Power System Monitoring, Operation and Control - https://digital-library.theiet.org/files/IET_GTD_CFP_NGSPSMOC.pdf