Assessment of transmission network connection solutions based on HVAC for offshore wind

IF 2 4区 工程技术 Q3 ENGINEERING, ELECTRICAL & ELECTRONIC
Mattia Deriu, Michela Migliori, Corrado Gadaleta, Marco Cortese, Enrico Maria Carlini, Maria Dicorato, Giuseppe Forte, Gioacchino Tricarico
{"title":"Assessment of transmission network connection solutions based on HVAC for offshore wind","authors":"Mattia Deriu,&nbsp;Michela Migliori,&nbsp;Corrado Gadaleta,&nbsp;Marco Cortese,&nbsp;Enrico Maria Carlini,&nbsp;Maria Dicorato,&nbsp;Giuseppe Forte,&nbsp;Gioacchino Tricarico","doi":"10.1049/gtd2.13252","DOIUrl":null,"url":null,"abstract":"<p>The diffusion of offshore wind power plants (OWPPs), useful to fulfil renewable diffusion policy targets, implies several technological challenges for integration in power transmission network. The definition of the OWPP connection to the transmission network affects possible exploitation of the assets, involves an evaluation of active power losses and loadability and points out the need for compensation devices, in order to comply with connection rules fixed by the grid operator. This paper proposes a methodology to determine the most suitable electric connection for an OWPP based on high-voltage alternating current (HVAC) cables, for providing indications for transmission system operators. In particular, different HVAC connection schemes for OWPPs are analysed, focusing on new 66 kV standard voltage and high-voltage levels, providing technical insight on transmission cable optimal operation conditions. An economic analysis is carried out by proper estimation of construction costs and production forecast, accounting for active power losses and reliability impact. The most suitable connection solution depending on OWPP size and distance in Italian framework is evaluated by means of synthetic techno-economic indicators, further analysing possible sensitivities of energy price and capacity factor.</p>","PeriodicalId":13261,"journal":{"name":"Iet Generation Transmission & Distribution","volume":"18 24","pages":"4209-4220"},"PeriodicalIF":2.0000,"publicationDate":"2024-12-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1049/gtd2.13252","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Iet Generation Transmission & Distribution","FirstCategoryId":"5","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1049/gtd2.13252","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

Abstract

The diffusion of offshore wind power plants (OWPPs), useful to fulfil renewable diffusion policy targets, implies several technological challenges for integration in power transmission network. The definition of the OWPP connection to the transmission network affects possible exploitation of the assets, involves an evaluation of active power losses and loadability and points out the need for compensation devices, in order to comply with connection rules fixed by the grid operator. This paper proposes a methodology to determine the most suitable electric connection for an OWPP based on high-voltage alternating current (HVAC) cables, for providing indications for transmission system operators. In particular, different HVAC connection schemes for OWPPs are analysed, focusing on new 66 kV standard voltage and high-voltage levels, providing technical insight on transmission cable optimal operation conditions. An economic analysis is carried out by proper estimation of construction costs and production forecast, accounting for active power losses and reliability impact. The most suitable connection solution depending on OWPP size and distance in Italian framework is evaluated by means of synthetic techno-economic indicators, further analysing possible sensitivities of energy price and capacity factor.

Abstract Image

求助全文
约1分钟内获得全文 求助全文
来源期刊
Iet Generation Transmission & Distribution
Iet Generation Transmission & Distribution 工程技术-工程:电子与电气
CiteScore
6.10
自引率
12.00%
发文量
301
审稿时长
5.4 months
期刊介绍: IET Generation, Transmission & Distribution is intended as a forum for the publication and discussion of current practice and future developments in electric power generation, transmission and distribution. Practical papers in which examples of good present practice can be described and disseminated are particularly sought. Papers of high technical merit relying on mathematical arguments and computation will be considered, but authors are asked to relegate, as far as possible, the details of analysis to an appendix. The scope of IET Generation, Transmission & Distribution includes the following: Design of transmission and distribution systems Operation and control of power generation Power system management, planning and economics Power system operation, protection and control Power system measurement and modelling Computer applications and computational intelligence in power flexible AC or DC transmission systems Special Issues. Current Call for papers: Next Generation of Synchrophasor-based Power System Monitoring, Operation and Control - https://digital-library.theiet.org/files/IET_GTD_CFP_NGSPSMOC.pdf
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信