A Pilot Study to Predict Lifetime of Resin-Based Materials for Denture: Presentation of an In Vitro Thermally-Accelerated Ageing Method.

Lionel Sadoun, Guy Ravalec, Géraldine Rohman, Claudine Wulfman
{"title":"A Pilot Study to Predict Lifetime of Resin-Based Materials for Denture: Presentation of an In Vitro Thermally-Accelerated Ageing Method.","authors":"Lionel Sadoun, Guy Ravalec, Géraldine Rohman, Claudine Wulfman","doi":"10.11607/ijp.8854","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The aim of this article was to present a method for predicting dental materials lifetime, using in vitro thermally accelerated ageing. The technique was tested to compare the behavior of 3 resin base materials for denture.</p><p><strong>Materials and methods: </strong>Bar-shaped samples of the poly(methyl methacrylate) PMMA based-resin Probase Hot (Probase), CAD/CAM disc Ivobase CAD (IvoCAD) and high-impact resin IvoCAP were aged in artificial saliva for 15, 30, 45, 60, 90, 120 and 180 days at 55°C, 75°C and 90°C. Flexural strength and surface roughness of the 3 resins for each ageing duration and temperature were measured for 3 samples (n=189). Using the time-temperature equivalence principle and the Arrhenius model, a master curve was constructed, the activation energy of the simulated ageing process was calculated and the lifetime of each material was estimated, based on degradation of flexural strength value over time.</p><p><strong>Results: </strong>The mean initial flexural strength was 87.98 ± 7.37, 79.35 ± 10.01 and 97.31 ± 4.97 MPa for IvoCAD, IvoCAP and Probase, respectively. Activation energies of the ageing in artificial saliva were measured at 81.9, 82.6 and 66.2 kJ/mol, respectively, and average lifetimes at 37°C were estimated at 19.5, 14.4 and 9.2 years.</p><p><strong>Conclusion: </strong>In this first approach to estimating the in vitro lifetime in artificial saliva of resin-based materials for dentures, the three materials met the expected criteria, validating the estimation method. Therefore, thermally-accelerated ageing and the Arrhenius model could be an interesting tool to add to routine tests used to validate new polymer materials and manufacturing processes.</p>","PeriodicalId":94232,"journal":{"name":"The International journal of prosthodontics","volume":"0 0","pages":"1-19"},"PeriodicalIF":0.0000,"publicationDate":"2024-12-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The International journal of prosthodontics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.11607/ijp.8854","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: The aim of this article was to present a method for predicting dental materials lifetime, using in vitro thermally accelerated ageing. The technique was tested to compare the behavior of 3 resin base materials for denture.

Materials and methods: Bar-shaped samples of the poly(methyl methacrylate) PMMA based-resin Probase Hot (Probase), CAD/CAM disc Ivobase CAD (IvoCAD) and high-impact resin IvoCAP were aged in artificial saliva for 15, 30, 45, 60, 90, 120 and 180 days at 55°C, 75°C and 90°C. Flexural strength and surface roughness of the 3 resins for each ageing duration and temperature were measured for 3 samples (n=189). Using the time-temperature equivalence principle and the Arrhenius model, a master curve was constructed, the activation energy of the simulated ageing process was calculated and the lifetime of each material was estimated, based on degradation of flexural strength value over time.

Results: The mean initial flexural strength was 87.98 ± 7.37, 79.35 ± 10.01 and 97.31 ± 4.97 MPa for IvoCAD, IvoCAP and Probase, respectively. Activation energies of the ageing in artificial saliva were measured at 81.9, 82.6 and 66.2 kJ/mol, respectively, and average lifetimes at 37°C were estimated at 19.5, 14.4 and 9.2 years.

Conclusion: In this first approach to estimating the in vitro lifetime in artificial saliva of resin-based materials for dentures, the three materials met the expected criteria, validating the estimation method. Therefore, thermally-accelerated ageing and the Arrhenius model could be an interesting tool to add to routine tests used to validate new polymer materials and manufacturing processes.

求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信