Beyond water: 3D laser scanning offers a cutting-edge alternative for upper limb volume assessment.

Antonio Marsocci, Sheila Santandrea, Elena Lanfranchi, Danilo Donati, Roberto Tedeschi
{"title":"Beyond water: 3D laser scanning offers a cutting-edge alternative for upper limb volume assessment.","authors":"Antonio Marsocci, Sheila Santandrea, Elena Lanfranchi, Danilo Donati, Roberto Tedeschi","doi":"10.1177/02683555241310358","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>The primary aim of this study was to evaluate the reliability and efficiency of a 3D laser scanner as a tool for volumetric measurement of the upper limbs, comparing it with the gold standard method of non-reflux water displacement. The study sought to determine whether the 3D scanner could serve as a reliable and time-efficient alternative in clinical settings, particularly for managing conditions like lymphedema.</p><p><strong>Methods: </strong>A total of 30 healthy participants (18 women, 12 men) were recruited, and volumetric measurements were taken using both the 3D scanner and water displacement methods. Inter-rater and intra-rater reliability were calculated using the Intraclass Correlation Coefficient (ICC), and agreement between the methods was assessed using a Bland-Altman plot. The time required for each measurement and data processing were recorded and compared between the two methods.</p><p><strong>Results: </strong>The 3D scanner demonstrated excellent inter-rater (ICC = 0.995) and intra-rater (ICC = 0.991) reliability, surpassing the water displacement method (ICC = 0.973 and 0.968, respectively). The Bland-Altman plot showed good agreement between the two methods, with only two measurements outside the 95% confidence limits. However, the 3D scanner required significantly more time for both measurement and data processing (28.55 seconds and 120 seconds, respectively) compared to water displacement (9.64 seconds).</p><p><strong>Conclusions: </strong>The 3D scanner offers high reliability and precision for upper limb volumetric measurements, potentially improving clinical management of conditions such as lymphedema. Despite longer acquisition times, its accuracy and versatility make it a promising tool for future clinical use, especially in scenarios where precise monitoring is crucial.</p>","PeriodicalId":94350,"journal":{"name":"Phlebology","volume":" ","pages":"2683555241310358"},"PeriodicalIF":0.0000,"publicationDate":"2024-12-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Phlebology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/02683555241310358","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: The primary aim of this study was to evaluate the reliability and efficiency of a 3D laser scanner as a tool for volumetric measurement of the upper limbs, comparing it with the gold standard method of non-reflux water displacement. The study sought to determine whether the 3D scanner could serve as a reliable and time-efficient alternative in clinical settings, particularly for managing conditions like lymphedema.

Methods: A total of 30 healthy participants (18 women, 12 men) were recruited, and volumetric measurements were taken using both the 3D scanner and water displacement methods. Inter-rater and intra-rater reliability were calculated using the Intraclass Correlation Coefficient (ICC), and agreement between the methods was assessed using a Bland-Altman plot. The time required for each measurement and data processing were recorded and compared between the two methods.

Results: The 3D scanner demonstrated excellent inter-rater (ICC = 0.995) and intra-rater (ICC = 0.991) reliability, surpassing the water displacement method (ICC = 0.973 and 0.968, respectively). The Bland-Altman plot showed good agreement between the two methods, with only two measurements outside the 95% confidence limits. However, the 3D scanner required significantly more time for both measurement and data processing (28.55 seconds and 120 seconds, respectively) compared to water displacement (9.64 seconds).

Conclusions: The 3D scanner offers high reliability and precision for upper limb volumetric measurements, potentially improving clinical management of conditions such as lymphedema. Despite longer acquisition times, its accuracy and versatility make it a promising tool for future clinical use, especially in scenarios where precise monitoring is crucial.

求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信