Adam Whitelock, Wendy Goodwin, Shaun Pratt, Katherine Nash
{"title":"Feline caudal vena cava to aorta ratio reference interval.","authors":"Adam Whitelock, Wendy Goodwin, Shaun Pratt, Katherine Nash","doi":"10.1177/1098612X241303309","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>The primary objective of this investigation was to ultrasonographically evaluate the caudal vena cava to aorta (CVC:Ao) ratio in healthy, conscious cats and to generate reference intervals. A secondary objective was to identify the site of examination with the least intra- and inter-observer variability. This investigation was undertaken to assess whether the CVC:Ao ratio holds promise as a technique to assess intravascular volume responsiveness in cats.</p><p><strong>Methods: </strong>In total, 42 healthy cats were included for reference interval generation. Ultrasound examinations were performed by two operators with each examination performed twice by each operator on the same occasion. Examinations were performed on conscious cats in left lateral recumbency. Ultrasound sites investigated were the subxiphoid, hepatic intercostal, hepatorenal and iliac bifurcation. Operators also assessed each site for 'ease of visualisation' on a scale of 0-3.</p><p><strong>Results: </strong>Reference intervals were generated for the CVC:Ao ratio at all four ultrasonographic sites. While each site demonstrated low variability around its mean ratio, all sites exhibited significant intra- and inter-observer variability. The hepatorenal and iliac bifurcation sites were found to be the easiest to visualise (score 3; well-defined visualisation of both vessels) and had reference intervals of 0.8-1.41 and 0.75-1.2, respectively.</p><p><strong>Conclusions and relevance: </strong>The ultrasonographic assessment of the CVC:Ao ratio was possible at four anatomical locations in the cat. The hepatorenal and iliac bifurcation may offer more readily assessable CVC:Ao ratios. Further studies are necessary to assess the utility of the CVC:Ao ratio in disease states, including in hypovolaemia and hypervolaemia.</p>","PeriodicalId":15851,"journal":{"name":"Journal of Feline Medicine and Surgery","volume":"26 12","pages":"1098612X241303309"},"PeriodicalIF":1.9000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11662323/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Feline Medicine and Surgery","FirstCategoryId":"97","ListUrlMain":"https://doi.org/10.1177/1098612X241303309","RegionNum":2,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"VETERINARY SCIENCES","Score":null,"Total":0}
引用次数: 0
Abstract
Objectives: The primary objective of this investigation was to ultrasonographically evaluate the caudal vena cava to aorta (CVC:Ao) ratio in healthy, conscious cats and to generate reference intervals. A secondary objective was to identify the site of examination with the least intra- and inter-observer variability. This investigation was undertaken to assess whether the CVC:Ao ratio holds promise as a technique to assess intravascular volume responsiveness in cats.
Methods: In total, 42 healthy cats were included for reference interval generation. Ultrasound examinations were performed by two operators with each examination performed twice by each operator on the same occasion. Examinations were performed on conscious cats in left lateral recumbency. Ultrasound sites investigated were the subxiphoid, hepatic intercostal, hepatorenal and iliac bifurcation. Operators also assessed each site for 'ease of visualisation' on a scale of 0-3.
Results: Reference intervals were generated for the CVC:Ao ratio at all four ultrasonographic sites. While each site demonstrated low variability around its mean ratio, all sites exhibited significant intra- and inter-observer variability. The hepatorenal and iliac bifurcation sites were found to be the easiest to visualise (score 3; well-defined visualisation of both vessels) and had reference intervals of 0.8-1.41 and 0.75-1.2, respectively.
Conclusions and relevance: The ultrasonographic assessment of the CVC:Ao ratio was possible at four anatomical locations in the cat. The hepatorenal and iliac bifurcation may offer more readily assessable CVC:Ao ratios. Further studies are necessary to assess the utility of the CVC:Ao ratio in disease states, including in hypovolaemia and hypervolaemia.
期刊介绍:
JFMS is an international, peer-reviewed journal aimed at both practitioners and researchers with an interest in the clinical veterinary healthcare of domestic cats. The journal is published monthly in two formats: ‘Classic’ editions containing high-quality original papers on all aspects of feline medicine and surgery, including basic research relevant to clinical practice; and dedicated ‘Clinical Practice’ editions primarily containing opinionated review articles providing state-of-the-art information for feline clinicians, along with other relevant articles such as consensus guidelines.