{"title":"Response Surface Methodology-Based Optimization of Coating Material, Coating Thickness, and Diameter of Dental Implant for Enhanced Mechanical Behavior Using Finite Element Method","authors":"Syed Masood Arif Bukhari,&nbsp;Rashida Qurashi,&nbsp;Naveed Husnain,&nbsp;Muhammad Aenan Sadiq,&nbsp;Muhammad Qasim Zafar,&nbsp;Muhammad Tuoqeer Anwar,&nbsp;Saqlain Abbas,&nbsp;Farrukh Arsalan Siddiqui,&nbsp;Sana Sarfraz","doi":"10.1002/adem.202401729","DOIUrl":null,"url":null,"abstract":"<p>\nSurface coatings have been found effective to enhance the osseointegration behavior and eliminate the issues associated with titanium implants. This research aims to optimize coating material, coating thickness, and implant diameter for reduced deformation, stress, and strain (response variables) which would enhance the performance. These input variables are optimized and analyzed using response surface methodology (RSM) and finite element method. Four different coating materials, i.e., hydroxyapatite, TiO<sub>2</sub>, TiC, and gold, are selected. Coating thickness is varied from 50 to 170 μm whereas implant body diameter from 4.5 to 5 mm based on RSM's design of experiment (DOE). The designing of dental implants is done in SOLIDWORKS 2023 while simulations are done on Ansys Workbench 19.2 based on DOE. RSM indicates that coating thickness is the most significant variable in determining all the three response variables. Optimized variables are coating thickness of 170 μm, coating material of TiC, and implant diameter of 5 mm. The results from prediction model of RSM are in strong agreement with the simulation results, indicating the validity of model. In terms of mechanical behavior and stability, TiC coating shows the highest desirability (0.988). However, von Mises stress values for all coating materials are in allowable limits.</p>","PeriodicalId":7275,"journal":{"name":"Advanced Engineering Materials","volume":"26 24","pages":""},"PeriodicalIF":3.4000,"publicationDate":"2024-10-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advanced Engineering Materials","FirstCategoryId":"88","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/adem.202401729","RegionNum":3,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MATERIALS SCIENCE, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

Abstract

Surface coatings have been found effective to enhance the osseointegration behavior and eliminate the issues associated with titanium implants. This research aims to optimize coating material, coating thickness, and implant diameter for reduced deformation, stress, and strain (response variables) which would enhance the performance. These input variables are optimized and analyzed using response surface methodology (RSM) and finite element method. Four different coating materials, i.e., hydroxyapatite, TiO2, TiC, and gold, are selected. Coating thickness is varied from 50 to 170 μm whereas implant body diameter from 4.5 to 5 mm based on RSM's design of experiment (DOE). The designing of dental implants is done in SOLIDWORKS 2023 while simulations are done on Ansys Workbench 19.2 based on DOE. RSM indicates that coating thickness is the most significant variable in determining all the three response variables. Optimized variables are coating thickness of 170 μm, coating material of TiC, and implant diameter of 5 mm. The results from prediction model of RSM are in strong agreement with the simulation results, indicating the validity of model. In terms of mechanical behavior and stability, TiC coating shows the highest desirability (0.988). However, von Mises stress values for all coating materials are in allowable limits.

Abstract Image

基于响应面方法学的有限元法优化牙科植入物的涂层材料、涂层厚度和直径以增强机械性能
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Advanced Engineering Materials
Advanced Engineering Materials 工程技术-材料科学:综合
CiteScore
5.70
自引率
5.60%
发文量
544
审稿时长
1.7 months
期刊介绍: Advanced Engineering Materials is the membership journal of three leading European Materials Societies - German Materials Society/DGM, - French Materials Society/SF2M, - Swiss Materials Federation/SVMT.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信