Optimization of Sensor Morphology and Sensing Performance in a Non-enzymatic Graphene FET Biosensor for Detection of Biomolecules in Complex Analytes

IF 2.2 4区 工程技术 Q3 ENGINEERING, ELECTRICAL & ELECTRONIC
V. N. Senthil Kumaran, M. Venkatesh, Abdulrahman Saad Alqahtani, Azath Mubarakali, P. Parthasarathy
{"title":"Optimization of Sensor Morphology and Sensing Performance in a Non-enzymatic Graphene FET Biosensor for Detection of Biomolecules in Complex Analytes","authors":"V. N. Senthil Kumaran,&nbsp;M. Venkatesh,&nbsp;Abdulrahman Saad Alqahtani,&nbsp;Azath Mubarakali,&nbsp;P. Parthasarathy","doi":"10.1007/s11664-024-11531-w","DOIUrl":null,"url":null,"abstract":"<div><p>Recent advances in ultrasensitive electrical biosensors using graphene nanostructures such as nanowalls and nanopores have increased the surface area-to-volume ratio. These structures provide signals at low biomolecule concentrations that are generally insufficient for vital measurements, especially in complex physiological analytes, making practical deployment difficult. A new, reproducible, and scalable chemical technique for constructing smooth graphene nanogrids enables molar biomolecule detection in field-effect transistor (FET) mode. We examine how pore morphology affects the sensing capability of label-free graphene nanoporous FET biosensors, aiming for sub-femtomolar detection limits with a good signal-to-noise ratio (SNR) in blood or urine serum. Despite problems including drain–source current sensitivity overlap due to high quantities of nonspecific antigens, our improved graphene nanogrid sensor detected hepatitis B (Hep-B) surface antigen in serum at sub-femtomolar levels. In serum containing 3 nM hepatitis C (Hep-C) as a nonspecific antigen, a pore diameter of 30 nm and length of 120 nm had the highest SNR and detected 0.25 fM Hep-B. We used a graphene nanogrid FET biosensor in heterodyne mode (80 kHz to 2 MHz) to quantify Hep-B down to 0.3 fM in blood using a probabilistic neural network (PNN) to reduce Debye screening effects. The performance of the PNN exceeded that of the polynomial fit and static neural network models by limiting quantification errors to 10%. Electrical resistance was linearly related to the Hep-C virus core antigen (HCVcAg) concentration (80–550 pg/mL) in real-time tests. After improvement of functionalization parameters, the SNR increased 70%, detecting 0.20 fM Hep-B virus molecules with 60% sensitivity and 6% standard deviation.</p></div>","PeriodicalId":626,"journal":{"name":"Journal of Electronic Materials","volume":"54 1","pages":"285 - 299"},"PeriodicalIF":2.2000,"publicationDate":"2024-10-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Electronic Materials","FirstCategoryId":"5","ListUrlMain":"https://link.springer.com/article/10.1007/s11664-024-11531-w","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

Abstract

Recent advances in ultrasensitive electrical biosensors using graphene nanostructures such as nanowalls and nanopores have increased the surface area-to-volume ratio. These structures provide signals at low biomolecule concentrations that are generally insufficient for vital measurements, especially in complex physiological analytes, making practical deployment difficult. A new, reproducible, and scalable chemical technique for constructing smooth graphene nanogrids enables molar biomolecule detection in field-effect transistor (FET) mode. We examine how pore morphology affects the sensing capability of label-free graphene nanoporous FET biosensors, aiming for sub-femtomolar detection limits with a good signal-to-noise ratio (SNR) in blood or urine serum. Despite problems including drain–source current sensitivity overlap due to high quantities of nonspecific antigens, our improved graphene nanogrid sensor detected hepatitis B (Hep-B) surface antigen in serum at sub-femtomolar levels. In serum containing 3 nM hepatitis C (Hep-C) as a nonspecific antigen, a pore diameter of 30 nm and length of 120 nm had the highest SNR and detected 0.25 fM Hep-B. We used a graphene nanogrid FET biosensor in heterodyne mode (80 kHz to 2 MHz) to quantify Hep-B down to 0.3 fM in blood using a probabilistic neural network (PNN) to reduce Debye screening effects. The performance of the PNN exceeded that of the polynomial fit and static neural network models by limiting quantification errors to 10%. Electrical resistance was linearly related to the Hep-C virus core antigen (HCVcAg) concentration (80–550 pg/mL) in real-time tests. After improvement of functionalization parameters, the SNR increased 70%, detecting 0.20 fM Hep-B virus molecules with 60% sensitivity and 6% standard deviation.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Electronic Materials
Journal of Electronic Materials 工程技术-材料科学:综合
CiteScore
4.10
自引率
4.80%
发文量
693
审稿时长
3.8 months
期刊介绍: The Journal of Electronic Materials (JEM) reports monthly on the science and technology of electronic materials, while examining new applications for semiconductors, magnetic alloys, dielectrics, nanoscale materials, and photonic materials. The journal welcomes articles on methods for preparing and evaluating the chemical, physical, electronic, and optical properties of these materials. Specific areas of interest are materials for state-of-the-art transistors, nanotechnology, electronic packaging, detectors, emitters, metallization, superconductivity, and energy applications. Review papers on current topics enable individuals in the field of electronics to keep abreast of activities in areas peripheral to their own. JEM also selects papers from conferences such as the Electronic Materials Conference, the U.S. Workshop on the Physics and Chemistry of II-VI Materials, and the International Conference on Thermoelectrics. It benefits both specialists and non-specialists in the electronic materials field. A journal of The Minerals, Metals & Materials Society.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信