V. N. Senthil Kumaran, M. Venkatesh, Abdulrahman Saad Alqahtani, Azath Mubarakali, P. Parthasarathy
{"title":"Optimization of Sensor Morphology and Sensing Performance in a Non-enzymatic Graphene FET Biosensor for Detection of Biomolecules in Complex Analytes","authors":"V. N. Senthil Kumaran, M. Venkatesh, Abdulrahman Saad Alqahtani, Azath Mubarakali, P. Parthasarathy","doi":"10.1007/s11664-024-11531-w","DOIUrl":null,"url":null,"abstract":"<div><p>Recent advances in ultrasensitive electrical biosensors using graphene nanostructures such as nanowalls and nanopores have increased the surface area-to-volume ratio. These structures provide signals at low biomolecule concentrations that are generally insufficient for vital measurements, especially in complex physiological analytes, making practical deployment difficult. A new, reproducible, and scalable chemical technique for constructing smooth graphene nanogrids enables molar biomolecule detection in field-effect transistor (FET) mode. We examine how pore morphology affects the sensing capability of label-free graphene nanoporous FET biosensors, aiming for sub-femtomolar detection limits with a good signal-to-noise ratio (SNR) in blood or urine serum. Despite problems including drain–source current sensitivity overlap due to high quantities of nonspecific antigens, our improved graphene nanogrid sensor detected hepatitis B (Hep-B) surface antigen in serum at sub-femtomolar levels. In serum containing 3 nM hepatitis C (Hep-C) as a nonspecific antigen, a pore diameter of 30 nm and length of 120 nm had the highest SNR and detected 0.25 fM Hep-B. We used a graphene nanogrid FET biosensor in heterodyne mode (80 kHz to 2 MHz) to quantify Hep-B down to 0.3 fM in blood using a probabilistic neural network (PNN) to reduce Debye screening effects. The performance of the PNN exceeded that of the polynomial fit and static neural network models by limiting quantification errors to 10%. Electrical resistance was linearly related to the Hep-C virus core antigen (HCVcAg) concentration (80–550 pg/mL) in real-time tests. After improvement of functionalization parameters, the SNR increased 70%, detecting 0.20 fM Hep-B virus molecules with 60% sensitivity and 6% standard deviation.</p></div>","PeriodicalId":626,"journal":{"name":"Journal of Electronic Materials","volume":"54 1","pages":"285 - 299"},"PeriodicalIF":2.2000,"publicationDate":"2024-10-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Electronic Materials","FirstCategoryId":"5","ListUrlMain":"https://link.springer.com/article/10.1007/s11664-024-11531-w","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0
Abstract
Recent advances in ultrasensitive electrical biosensors using graphene nanostructures such as nanowalls and nanopores have increased the surface area-to-volume ratio. These structures provide signals at low biomolecule concentrations that are generally insufficient for vital measurements, especially in complex physiological analytes, making practical deployment difficult. A new, reproducible, and scalable chemical technique for constructing smooth graphene nanogrids enables molar biomolecule detection in field-effect transistor (FET) mode. We examine how pore morphology affects the sensing capability of label-free graphene nanoporous FET biosensors, aiming for sub-femtomolar detection limits with a good signal-to-noise ratio (SNR) in blood or urine serum. Despite problems including drain–source current sensitivity overlap due to high quantities of nonspecific antigens, our improved graphene nanogrid sensor detected hepatitis B (Hep-B) surface antigen in serum at sub-femtomolar levels. In serum containing 3 nM hepatitis C (Hep-C) as a nonspecific antigen, a pore diameter of 30 nm and length of 120 nm had the highest SNR and detected 0.25 fM Hep-B. We used a graphene nanogrid FET biosensor in heterodyne mode (80 kHz to 2 MHz) to quantify Hep-B down to 0.3 fM in blood using a probabilistic neural network (PNN) to reduce Debye screening effects. The performance of the PNN exceeded that of the polynomial fit and static neural network models by limiting quantification errors to 10%. Electrical resistance was linearly related to the Hep-C virus core antigen (HCVcAg) concentration (80–550 pg/mL) in real-time tests. After improvement of functionalization parameters, the SNR increased 70%, detecting 0.20 fM Hep-B virus molecules with 60% sensitivity and 6% standard deviation.
期刊介绍:
The Journal of Electronic Materials (JEM) reports monthly on the science and technology of electronic materials, while examining new applications for semiconductors, magnetic alloys, dielectrics, nanoscale materials, and photonic materials. The journal welcomes articles on methods for preparing and evaluating the chemical, physical, electronic, and optical properties of these materials. Specific areas of interest are materials for state-of-the-art transistors, nanotechnology, electronic packaging, detectors, emitters, metallization, superconductivity, and energy applications.
Review papers on current topics enable individuals in the field of electronics to keep abreast of activities in areas peripheral to their own. JEM also selects papers from conferences such as the Electronic Materials Conference, the U.S. Workshop on the Physics and Chemistry of II-VI Materials, and the International Conference on Thermoelectrics. It benefits both specialists and non-specialists in the electronic materials field.
A journal of The Minerals, Metals & Materials Society.