Influence of dosimetry accuracy on the correlation with treatment outcome in a preliminary PSMA radiopharmaceutical therapy study

IF 8.6 1区 医学 Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Jiaxi Hu, Robert Seifert, Sofia Karkampouna, Carlos Vinicius Gomes, Song Xue, Ali Afshar-Ormieh, Axel Rominger, Kuangyu Shi
{"title":"Influence of dosimetry accuracy on the correlation with treatment outcome in a preliminary PSMA radiopharmaceutical therapy study","authors":"Jiaxi Hu, Robert Seifert, Sofia Karkampouna, Carlos Vinicius Gomes, Song Xue, Ali Afshar-Ormieh, Axel Rominger, Kuangyu Shi","doi":"10.1007/s00259-024-07010-3","DOIUrl":null,"url":null,"abstract":"<h3 data-test=\"abstract-sub-heading\">Introduction</h3><p>Despite the potential of dosimetry in optimizing personalized radiopharmaceutical therapy (RPT), its limited clinical implementation impedes the development of simplified protocols for routine adoption. However, simplifications may introduce errors in dosimetry, prompting questions about their impact on clinical practice.</p><h3 data-test=\"abstract-sub-heading\">Materials and methods</h3><p>In this retrospective study, we analyzed data from 21 patients diagnosed with metastatic castration-resistant prostate cancer (mCRPC) who underwent multiple cycles of <sup>177</sup>Lu-PSMA-617 RPT treatment. Cumulative dosimetry of all the treatment cycles was calculated using both the standard multi-time point dosimetry (MTPD) method and the single time-point dosimetry (STPD, Hänscheid approximation) method for the same cohort. Their correlations with treatment outcome (PSA decline rate and overall survival, OS) and complication risk (anaemia grade) were investigated. The Fisher's Z-Transformed test was performed to statistically evaluate the difference between the correlations.</p><h3 data-test=\"abstract-sub-heading\">Results</h3><p>STPD showed a non-significant difference in correlation with PSA decline rate, despite a mean percentage error (MPE) of up to 36.44% in tumor dosimetry compared to MTPD (MTPD: rho = -0.39, <i>p</i> &lt; 0.001; STPD: rho = -0.46, <i>p</i> &lt; 0.001; Z = 0.58, <i>p</i> = 0.56). Both STPD<sub>total</sub> and MTPD<sub>total</sub> demonstrated a significant impact on OS (STPD<sub>total</sub>: Hazard Ratio = 1.05, <i>p</i> &lt; 0.05, log-transformed MTPD<sub>total</sub>: Hazard Ratio = 3.41, <i>p</i> &lt; 0.05, log-transformed STPD<sub>total</sub>: Hazard Ratio = 8.06, <i>p</i> &lt; 0.05). Additionally, despite a MPE of up to -40.26% in bone marrow dosimetry, STPD showed a non-significant difference in correlation with anemia grade (MTPD: rho = 0.35, <i>p</i> &lt; 0.001; STPD: rho = 0.40, <i>p</i> &lt; 0.001; Z = -0.39, <i>p</i> = 0.70).</p><h3 data-test=\"abstract-sub-heading\">Conclusion</h3><p>The preliminary findings from a small cohort indicate that the reduced accuracy of a clinically simplified protocol may not diminish the clinical therapy outcome predictive value of dosimetry. Future thorough systematic investigations may be needed to determine the clinically acceptable level of accuracy for dosimetry.</p>","PeriodicalId":11909,"journal":{"name":"European Journal of Nuclear Medicine and Molecular Imaging","volume":"31 1","pages":""},"PeriodicalIF":8.6000,"publicationDate":"2024-12-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Nuclear Medicine and Molecular Imaging","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00259-024-07010-3","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction

Despite the potential of dosimetry in optimizing personalized radiopharmaceutical therapy (RPT), its limited clinical implementation impedes the development of simplified protocols for routine adoption. However, simplifications may introduce errors in dosimetry, prompting questions about their impact on clinical practice.

Materials and methods

In this retrospective study, we analyzed data from 21 patients diagnosed with metastatic castration-resistant prostate cancer (mCRPC) who underwent multiple cycles of 177Lu-PSMA-617 RPT treatment. Cumulative dosimetry of all the treatment cycles was calculated using both the standard multi-time point dosimetry (MTPD) method and the single time-point dosimetry (STPD, Hänscheid approximation) method for the same cohort. Their correlations with treatment outcome (PSA decline rate and overall survival, OS) and complication risk (anaemia grade) were investigated. The Fisher's Z-Transformed test was performed to statistically evaluate the difference between the correlations.

Results

STPD showed a non-significant difference in correlation with PSA decline rate, despite a mean percentage error (MPE) of up to 36.44% in tumor dosimetry compared to MTPD (MTPD: rho = -0.39, p < 0.001; STPD: rho = -0.46, p < 0.001; Z = 0.58, p = 0.56). Both STPDtotal and MTPDtotal demonstrated a significant impact on OS (STPDtotal: Hazard Ratio = 1.05, p < 0.05, log-transformed MTPDtotal: Hazard Ratio = 3.41, p < 0.05, log-transformed STPDtotal: Hazard Ratio = 8.06, p < 0.05). Additionally, despite a MPE of up to -40.26% in bone marrow dosimetry, STPD showed a non-significant difference in correlation with anemia grade (MTPD: rho = 0.35, p < 0.001; STPD: rho = 0.40, p < 0.001; Z = -0.39, p = 0.70).

Conclusion

The preliminary findings from a small cohort indicate that the reduced accuracy of a clinically simplified protocol may not diminish the clinical therapy outcome predictive value of dosimetry. Future thorough systematic investigations may be needed to determine the clinically acceptable level of accuracy for dosimetry.

求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
15.60
自引率
9.90%
发文量
392
审稿时长
3 months
期刊介绍: The European Journal of Nuclear Medicine and Molecular Imaging serves as a platform for the exchange of clinical and scientific information within nuclear medicine and related professions. It welcomes international submissions from professionals involved in the functional, metabolic, and molecular investigation of diseases. The journal's coverage spans physics, dosimetry, radiation biology, radiochemistry, and pharmacy, providing high-quality peer review by experts in the field. Known for highly cited and downloaded articles, it ensures global visibility for research work and is part of the EJNMMI journal family.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信