Biological Properties of Bioceramic Sealers on Osteoblastic Cells: A Comparative Study.

Brazilian dental journal Pub Date : 2024-12-16 eCollection Date: 2024-01-01 DOI:10.1590/0103-6440202406037
Angelita Piovezana Guerra, Danielle Gregorio, Gean Carlos Yamamoto, Nathalia Thalitha Bernardes Dos Santos, Regina Celia Poli-Frederico, Luciana Prado Maia
{"title":"Biological Properties of Bioceramic Sealers on Osteoblastic Cells: A Comparative Study.","authors":"Angelita Piovezana Guerra, Danielle Gregorio, Gean Carlos Yamamoto, Nathalia Thalitha Bernardes Dos Santos, Regina Celia Poli-Frederico, Luciana Prado Maia","doi":"10.1590/0103-6440202406037","DOIUrl":null,"url":null,"abstract":"<p><p>This study aimed to assess the biological properties of two ready-to-use bioceramic sealers (EndoSequence BC Sealer - EBCS; Bio-C Sealer - BCS) on osteoblastic lineage cells. MC3T3 osteoblast-like cells were exposed to extracts of bioceramic materials. Cytotoxicity was evaluated using the MTT method, genotoxicity was assessed by the micronucleus test and the expression of BMP1, BMP2 and ALP was measured by RT-qPCR, after 1, 3 and 7 days. Wound healing was monitored at 1, 2 and 3-day intervals using the scratch test. Statistical analysis involved a two-factor ANOVA, followed by the Tukey Test for multiple comparisons (α=0.05). Cytotoxicity assessment revealed no significant differences between the materials and the control group at any of the time points, indicating that neither material exhibited cytotoxic effects. However, both cements induced greater micronuclei formation compared to the control on days 1 and 7 (p<0.05) when evaluating genotoxicity. No significant differences between the groups were observed in wound healing at any of the time intervals. Both biomaterials upregulated the expression of BMP1, BMP2 and ALP. The two bioceramic sealers exhibited comparable biological properties, including cytocompatibility, promotion of wound healing, and upregulation of bone formation-related genes in osteoblast-like cells. While these results suggest the potential for safe clinical application, the observed genotoxicity warrants caution. Therefore, while the null hypothesis-that the two bioceramic sealers exhibit analogous properties-was accepted in terms of cytocompatibility and gene expression, further investigation is essential to fully ensure their safety and efficacy in bone-related procedures.</p>","PeriodicalId":101363,"journal":{"name":"Brazilian dental journal","volume":"35 ","pages":"e246037"},"PeriodicalIF":0.0000,"publicationDate":"2024-12-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11654336/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Brazilian dental journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1590/0103-6440202406037","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

This study aimed to assess the biological properties of two ready-to-use bioceramic sealers (EndoSequence BC Sealer - EBCS; Bio-C Sealer - BCS) on osteoblastic lineage cells. MC3T3 osteoblast-like cells were exposed to extracts of bioceramic materials. Cytotoxicity was evaluated using the MTT method, genotoxicity was assessed by the micronucleus test and the expression of BMP1, BMP2 and ALP was measured by RT-qPCR, after 1, 3 and 7 days. Wound healing was monitored at 1, 2 and 3-day intervals using the scratch test. Statistical analysis involved a two-factor ANOVA, followed by the Tukey Test for multiple comparisons (α=0.05). Cytotoxicity assessment revealed no significant differences between the materials and the control group at any of the time points, indicating that neither material exhibited cytotoxic effects. However, both cements induced greater micronuclei formation compared to the control on days 1 and 7 (p<0.05) when evaluating genotoxicity. No significant differences between the groups were observed in wound healing at any of the time intervals. Both biomaterials upregulated the expression of BMP1, BMP2 and ALP. The two bioceramic sealers exhibited comparable biological properties, including cytocompatibility, promotion of wound healing, and upregulation of bone formation-related genes in osteoblast-like cells. While these results suggest the potential for safe clinical application, the observed genotoxicity warrants caution. Therefore, while the null hypothesis-that the two bioceramic sealers exhibit analogous properties-was accepted in terms of cytocompatibility and gene expression, further investigation is essential to fully ensure their safety and efficacy in bone-related procedures.

生物陶瓷封口处成骨细胞生物学特性的比较研究。
本研究旨在评估两种即用型生物陶瓷密封剂(EndoSequence BC Sealer - EBCS;Bio-C Sealer - BCS)对成骨细胞谱系的影响。MC3T3成骨细胞样细胞暴露于生物陶瓷材料提取物中。1、3、7 d后,采用MTT法评价细胞毒性,微核试验评价遗传毒性,RT-qPCR检测BMP1、BMP2和ALP的表达。采用划痕试验,每隔1、2和3天监测伤口愈合情况。统计分析采用双因素方差分析,多重比较采用Tukey检验(α=0.05)。细胞毒性评估显示,在任何时间点,材料与对照组之间均无显著差异,表明两种材料均未表现出细胞毒性作用。然而,在第1天和第7天,与对照组相比,这两种水泥都诱导了更大的微核形成
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信