{"title":"[Prospective study of three-dimensional-printed <i>in vitro</i> guide plates assisted hip arthroscopy in treatment of Cam-type femoroacetabular impingement].","authors":"Dongqiang Yang, Songsong Wei, Yijun Liu, Yong Hu","doi":"10.7507/1002-1892.202403052","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>A prospective study was conducted to investigate the feasibility and effectiveness of three-dimensional printed <i>in vitro</i> guide plates assisted hip arthroscopy in the treatment of Cam-type femoroacetabular impingement (FAI).</p><p><strong>Methods: </strong>The clinical data of 25 patients with Cam-type FAI who met the selection criteria between December 2016 and September 2022 were collected. There were 13 males and 12 females with an average age of 42 years (range, 19-66 years). The disease duration ranged from 3 to 120 months, with an average of 22.2 months. The preoperative range of internal rotation-external rotation was (28.70±4.50)°, α angle was (69.04±0.99)°, visual analogue scale (VAS) score was 6.5±0.2, and modified Harris hip score (HHS) was 50.5±0.7. All patients were treated with hip arthroscopy assisted by three-dimensional printed <i>in vitro</i> guide plate. The occurrence of complications was observed postoperatively, α angle of the affected hip joint was measured on Dunn X-ray film, and the glenoid labrum injury was observed by MRI. The percentage of overlap between the Cam plasty area and the preoperative simulated grinding area was calculated by three-dimensional CT+reconstruction. The effectiveness was evaluated by VAS score and modified HHS score.</p><p><strong>Results: </strong>Postoperative dorsalis pedis numbness occurred in 1 case, and the symptoms disappeared after 1 month of conventional drug treatment such as neurotrophy. Two cases of perineal skin injury occurred, and healed after symptomatic treatment. There was no male erectile dysfunction, deep incision infection, pulmonary embolism, or other serious complications occurred. The percentage of overlap between the Cam plasty area and the preoperative simulated grinding area was 81.6%-95.3%, with an average of 89.8%. All 25 patients were followed up 6-12 months, with an average of 8 months. At last follow-up, the range of internal rotation-external rotation was (40.10±2.98)°, α angle was (43.72±0.84)°, VAS score was 1.8±0.2, and the modified HHS score was 72.1±1.3, which significantly improved when compared with preoperative ones ( <i>P</i><0.05).</p><p><strong>Conclusion: </strong>The treatment of Cam-type FAI with three-dimensional printed <i>in vitro</i> guide plates assisted hip arthroscopy is safe and feasible, and can achieve good effectiveness.</p>","PeriodicalId":23979,"journal":{"name":"中国修复重建外科杂志","volume":"38 12","pages":"1474-1479"},"PeriodicalIF":0.0000,"publicationDate":"2024-12-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"中国修复重建外科杂志","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.7507/1002-1892.202403052","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0
Abstract
Objective: A prospective study was conducted to investigate the feasibility and effectiveness of three-dimensional printed in vitro guide plates assisted hip arthroscopy in the treatment of Cam-type femoroacetabular impingement (FAI).
Methods: The clinical data of 25 patients with Cam-type FAI who met the selection criteria between December 2016 and September 2022 were collected. There were 13 males and 12 females with an average age of 42 years (range, 19-66 years). The disease duration ranged from 3 to 120 months, with an average of 22.2 months. The preoperative range of internal rotation-external rotation was (28.70±4.50)°, α angle was (69.04±0.99)°, visual analogue scale (VAS) score was 6.5±0.2, and modified Harris hip score (HHS) was 50.5±0.7. All patients were treated with hip arthroscopy assisted by three-dimensional printed in vitro guide plate. The occurrence of complications was observed postoperatively, α angle of the affected hip joint was measured on Dunn X-ray film, and the glenoid labrum injury was observed by MRI. The percentage of overlap between the Cam plasty area and the preoperative simulated grinding area was calculated by three-dimensional CT+reconstruction. The effectiveness was evaluated by VAS score and modified HHS score.
Results: Postoperative dorsalis pedis numbness occurred in 1 case, and the symptoms disappeared after 1 month of conventional drug treatment such as neurotrophy. Two cases of perineal skin injury occurred, and healed after symptomatic treatment. There was no male erectile dysfunction, deep incision infection, pulmonary embolism, or other serious complications occurred. The percentage of overlap between the Cam plasty area and the preoperative simulated grinding area was 81.6%-95.3%, with an average of 89.8%. All 25 patients were followed up 6-12 months, with an average of 8 months. At last follow-up, the range of internal rotation-external rotation was (40.10±2.98)°, α angle was (43.72±0.84)°, VAS score was 1.8±0.2, and the modified HHS score was 72.1±1.3, which significantly improved when compared with preoperative ones ( P<0.05).
Conclusion: The treatment of Cam-type FAI with three-dimensional printed in vitro guide plates assisted hip arthroscopy is safe and feasible, and can achieve good effectiveness.