Clinical outcomes of modified left ventricular assist device driveline management.

IF 1.1 4区 医学 Q4 ENGINEERING, BIOMEDICAL
Shusuke Imaoka, Noriyuki Kashiyama, Daisuke Yoshioka, Shunsuke Saito, Takuji Kawamura, Ai Kawamura, Ryohei Matsuura, Yusuke Misumi, Koichi Toda, Shigeru Miyagawa
{"title":"Clinical outcomes of modified left ventricular assist device driveline management.","authors":"Shusuke Imaoka, Noriyuki Kashiyama, Daisuke Yoshioka, Shunsuke Saito, Takuji Kawamura, Ai Kawamura, Ryohei Matsuura, Yusuke Misumi, Koichi Toda, Shigeru Miyagawa","doi":"10.1007/s10047-024-01482-8","DOIUrl":null,"url":null,"abstract":"<p><p>Left ventricular assist devices (LVADs) are implanted in patients with heart failure to support cardiac circulation. However, no standardized methods have been established for LVAD driveline exit site management for the prevention of infections. Therefore, this study evaluated the efficacy of modified driveline management compared with that of conventional driveline management. We retrospectively assessed the outcomes of 262 patients who underwent continuous-flow LVAD implantation between January 2005 and March 2023 at Osaka University in Japan. In conventional driveline management, an LVAD driveline penetrates the skin along the body surface and is fixed near the penetration site (n = 224). In contrast, in our modified fixation method, the LVAD driveline vertically penetrates the skin to prevent ischemia at the driveline exit site and is fixed at a distant abdominal site to prevent the movement of the driveline exit site due to body movement (n = 38). The rates of freedom from LVAD driveline infection in patients with conventional driveline management were 86, 75, and 63% at 1, 2, and 3 years after LVAD implantation, respectively. The rate of freedom from LVAD driveline infection in patients managed by the modified fixation method was 91% at 1, 2, as well as 3 years after LVAD implantation. The freedom rates from LVAD driveline infection in the patients with modified fixation method was lower than in the patients with the conventional method (p = 0.04). Our study revealed that the modified fixation method may offer the possibility for preventing LVAD driveline infection.</p>","PeriodicalId":15177,"journal":{"name":"Journal of Artificial Organs","volume":" ","pages":""},"PeriodicalIF":1.1000,"publicationDate":"2024-12-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Artificial Organs","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1007/s10047-024-01482-8","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Left ventricular assist devices (LVADs) are implanted in patients with heart failure to support cardiac circulation. However, no standardized methods have been established for LVAD driveline exit site management for the prevention of infections. Therefore, this study evaluated the efficacy of modified driveline management compared with that of conventional driveline management. We retrospectively assessed the outcomes of 262 patients who underwent continuous-flow LVAD implantation between January 2005 and March 2023 at Osaka University in Japan. In conventional driveline management, an LVAD driveline penetrates the skin along the body surface and is fixed near the penetration site (n = 224). In contrast, in our modified fixation method, the LVAD driveline vertically penetrates the skin to prevent ischemia at the driveline exit site and is fixed at a distant abdominal site to prevent the movement of the driveline exit site due to body movement (n = 38). The rates of freedom from LVAD driveline infection in patients with conventional driveline management were 86, 75, and 63% at 1, 2, and 3 years after LVAD implantation, respectively. The rate of freedom from LVAD driveline infection in patients managed by the modified fixation method was 91% at 1, 2, as well as 3 years after LVAD implantation. The freedom rates from LVAD driveline infection in the patients with modified fixation method was lower than in the patients with the conventional method (p = 0.04). Our study revealed that the modified fixation method may offer the possibility for preventing LVAD driveline infection.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Artificial Organs
Journal of Artificial Organs 医学-工程:生物医学
CiteScore
2.80
自引率
15.40%
发文量
68
审稿时长
6-12 weeks
期刊介绍: The aim of the Journal of Artificial Organs is to introduce to colleagues worldwide a broad spectrum of important new achievements in the field of artificial organs, ranging from fundamental research to clinical applications. The scope of the Journal of Artificial Organs encompasses but is not restricted to blood purification, cardiovascular intervention, biomaterials, and artificial metabolic organs. Additionally, the journal will cover technical and industrial innovations. Membership in the Japanese Society for Artificial Organs is not a prerequisite for submission.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信