A brief effective screening protocol for identifying cataract patients with binocular vision anomalies.

IF 1.7 4区 医学 Q3 OPHTHALMOLOGY
Qing-Qing Tan, Jia-Hao Tan, Chang-Kang Luo, Chun-Yan Lai, Wei Zhao, Chang-Jun Lan, James Lewis, Saeed Aljohani, Xuan Liao, Mitchell Scheiman
{"title":"A brief effective screening protocol for identifying cataract patients with binocular vision anomalies.","authors":"Qing-Qing Tan, Jia-Hao Tan, Chang-Kang Luo, Chun-Yan Lai, Wei Zhao, Chang-Jun Lan, James Lewis, Saeed Aljohani, Xuan Liao, Mitchell Scheiman","doi":"10.1186/s12886-024-03807-w","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>To compare the effectiveness of a brief binocular vision screening protocol to a comprehensive examination for detecting binocular vision anomalies before and after cataract surgery.</p><p><strong>Methods: </strong>A comprehensive binocular vision test battery as a gold standard were administered on recruited patients before the first surgery and at the third visit after surgery on the second eye. A receiver operating characteristic (ROC) curve was plotted to illustrate the diagnostic ability of each test. In addition, a univariate logistic regression analysis was performed to further determine the contribution of each preoperative test to the prediction of pre- and post-surgical binocular vision anomalies.</p><p><strong>Results: </strong>Significant differences were shown for the difference in phoria from distance to near measured by the cover test (Area Under Curve [AUC] = 0.96, P < 0.01), step vergence testing of positive fusional vergence at distance (AUC = 0.71, P < 0.01) and near (AUC = 0.77, P < 0.01). The other tests did not show statistically significant differences. The ROC curve generated by combining the difference in distance and near phoria with positive fusional vergence at both distance and near demonstrated a more robust measure of diagnostic accuracy. (AUC = 0.98, P < 0.01).</p><p><strong>Conclusion: </strong>Distance and near phoria difference measured by cover test has similar effectiveness as a comprehensive binocular vision testing protocol for the diagnosis of binocular vision anomalies. Distance and near positive fusional vergence measured by step vergence testing also have significant predictive value. A combination of the two tests is an outstanding screening protocol for binocular vision anomalies before cataract surgery.</p><p><strong>Trial registration: </strong>The study was registered at ClinicalTrials.gov (NCT03592615, Date of registration: July 19, 2018).</p>","PeriodicalId":9058,"journal":{"name":"BMC Ophthalmology","volume":"24 1","pages":"536"},"PeriodicalIF":1.7000,"publicationDate":"2024-12-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"BMC Ophthalmology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s12886-024-03807-w","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background: To compare the effectiveness of a brief binocular vision screening protocol to a comprehensive examination for detecting binocular vision anomalies before and after cataract surgery.

Methods: A comprehensive binocular vision test battery as a gold standard were administered on recruited patients before the first surgery and at the third visit after surgery on the second eye. A receiver operating characteristic (ROC) curve was plotted to illustrate the diagnostic ability of each test. In addition, a univariate logistic regression analysis was performed to further determine the contribution of each preoperative test to the prediction of pre- and post-surgical binocular vision anomalies.

Results: Significant differences were shown for the difference in phoria from distance to near measured by the cover test (Area Under Curve [AUC] = 0.96, P < 0.01), step vergence testing of positive fusional vergence at distance (AUC = 0.71, P < 0.01) and near (AUC = 0.77, P < 0.01). The other tests did not show statistically significant differences. The ROC curve generated by combining the difference in distance and near phoria with positive fusional vergence at both distance and near demonstrated a more robust measure of diagnostic accuracy. (AUC = 0.98, P < 0.01).

Conclusion: Distance and near phoria difference measured by cover test has similar effectiveness as a comprehensive binocular vision testing protocol for the diagnosis of binocular vision anomalies. Distance and near positive fusional vergence measured by step vergence testing also have significant predictive value. A combination of the two tests is an outstanding screening protocol for binocular vision anomalies before cataract surgery.

Trial registration: The study was registered at ClinicalTrials.gov (NCT03592615, Date of registration: July 19, 2018).

求助全文
约1分钟内获得全文 求助全文
来源期刊
BMC Ophthalmology
BMC Ophthalmology OPHTHALMOLOGY-
CiteScore
3.40
自引率
5.00%
发文量
441
审稿时长
6-12 weeks
期刊介绍: BMC Ophthalmology is an open access, peer-reviewed journal that considers articles on all aspects of the prevention, diagnosis and management of eye disorders, as well as related molecular genetics, pathophysiology, and epidemiology.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信