In Vitro and In Vivo Comparison of Random versus Site-Specific Conjugation of Bifunctional Chelating Agents to the CD33-Binding Antibody for Use in Alpha- and Beta-Radioimmunotherapy
Kevin J. H. Allen, Connor Frank, Rubin Jiao, Mackenzie E. Malo, Michele Bello, Laura De Nardo, Laura Meléndez-Alafort and Ekaterina Dadachova*,
{"title":"In Vitro and In Vivo Comparison of Random versus Site-Specific Conjugation of Bifunctional Chelating Agents to the CD33-Binding Antibody for Use in Alpha- and Beta-Radioimmunotherapy","authors":"Kevin J. H. Allen, Connor Frank, Rubin Jiao, Mackenzie E. Malo, Michele Bello, Laura De Nardo, Laura Meléndez-Alafort and Ekaterina Dadachova*, ","doi":"10.1021/acsomega.4c0945010.1021/acsomega.4c09450","DOIUrl":null,"url":null,"abstract":"<p >Radiometal chelator conjugation is a cornerstone of radioimmunotherapy (RIT). Continued interest in selective placement of chelators remains an active topic of discussion in the field. With several simple site-specific methods being recently reported, it was of interest to investigate the benefits and potential drawbacks of the site-specific method with a full comparison to a more typical random conjugation method that is currently utilized in clinical applications. In this study, the conjugation methods were evaluated side by side to determine the utility of both methods using commercially available random and site-specific conjugation reagents by performing antigen binding; radiolabeling with <sup>64</sup>Cu, <sup>177</sup>Lu, and <sup>225</sup>Ac radioisotopes; antibody-conjugate stability, cytotoxicity, in vivo distribution, pharmacokinetics analyses, and dosimetry to gather a whole data set for preclinical investigation. Evaluation revealed that both methods performed similarly during most experiments with the site-specific method, resulting in higher binding capacity of the antibody conjugate via flow cytometry. Radiolabeling was not significantly different between two methods, while stability showed that the site-specifically conjugated antibody was somewhat more stable at 37 °C in human serum over 1 week. In vitro experiments demonstrated less cell killing with the random conjugation method, while in vivo experiments showed no statistical differences in tumor uptake between conjugation methods. Dosimetry calculations were performed using the acquired PET/CT data and showed that apart from the liver, there was no significant difference in radiation doses delivered by either antibody conjugate. These results demonstrate that both methods are viable for future work, while the site-specific method offers several potential advantages and, in some cases, improved efficacy.</p>","PeriodicalId":22,"journal":{"name":"ACS Omega","volume":"9 50","pages":"50000–50011 50000–50011"},"PeriodicalIF":3.7000,"publicationDate":"2024-12-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://pubs.acs.org/doi/epdf/10.1021/acsomega.4c09450","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Omega","FirstCategoryId":"92","ListUrlMain":"https://pubs.acs.org/doi/10.1021/acsomega.4c09450","RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0
Abstract
Radiometal chelator conjugation is a cornerstone of radioimmunotherapy (RIT). Continued interest in selective placement of chelators remains an active topic of discussion in the field. With several simple site-specific methods being recently reported, it was of interest to investigate the benefits and potential drawbacks of the site-specific method with a full comparison to a more typical random conjugation method that is currently utilized in clinical applications. In this study, the conjugation methods were evaluated side by side to determine the utility of both methods using commercially available random and site-specific conjugation reagents by performing antigen binding; radiolabeling with 64Cu, 177Lu, and 225Ac radioisotopes; antibody-conjugate stability, cytotoxicity, in vivo distribution, pharmacokinetics analyses, and dosimetry to gather a whole data set for preclinical investigation. Evaluation revealed that both methods performed similarly during most experiments with the site-specific method, resulting in higher binding capacity of the antibody conjugate via flow cytometry. Radiolabeling was not significantly different between two methods, while stability showed that the site-specifically conjugated antibody was somewhat more stable at 37 °C in human serum over 1 week. In vitro experiments demonstrated less cell killing with the random conjugation method, while in vivo experiments showed no statistical differences in tumor uptake between conjugation methods. Dosimetry calculations were performed using the acquired PET/CT data and showed that apart from the liver, there was no significant difference in radiation doses delivered by either antibody conjugate. These results demonstrate that both methods are viable for future work, while the site-specific method offers several potential advantages and, in some cases, improved efficacy.
ACS OmegaChemical Engineering-General Chemical Engineering
CiteScore
6.60
自引率
4.90%
发文量
3945
审稿时长
2.4 months
期刊介绍:
ACS Omega is an open-access global publication for scientific articles that describe new findings in chemistry and interfacing areas of science, without any perceived evaluation of immediate impact.