Short-Term Results of Multiwavelength Photobiomodulation in Retinitis Pigmentosa.

Clinical ophthalmology (Auckland, N.Z.) Pub Date : 2024-12-13 eCollection Date: 2024-01-01 DOI:10.2147/OPTH.S483722
Rubens Camargo Siqueira, Tainara Souza Pinho, Cinara Cássia Brandão
{"title":"Short-Term Results of Multiwavelength Photobiomodulation in Retinitis Pigmentosa.","authors":"Rubens Camargo Siqueira, Tainara Souza Pinho, Cinara Cássia Brandão","doi":"10.2147/OPTH.S483722","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To assess the short-term effects of Multiwavelength Photobiomodulation (LumiThera Valeda Light Delivery System) on retinal functional behavior in patients with retinitis pigmentosa (RP).</p><p><strong>Materials and methods: </strong>Twelve RP patients (24 eyes) underwent treatment involving nine photobiomodulation (PBM) sessions using the Valeda system, which emits three distinct wavelengths within the yellow (590 nm; 4 mW/cm2), red (660 nm; 65 mW/cm2), and near-infrared (NIR) (850 nm; 0.6 mW/cm2) spectrum. All evaluations were conducted four weeks post-therapy. The treated eye was compared with baseline (pre-therapy). Following nine PBM sessions, assessments included best-corrected visual acuity (BCVA), retinal sensitivity, and characteristics of the correction area via fundus automated perimetry using the Compass system. Additionally, a functional and structural assessment of the retina was performed using multifocal electroretinography (ERG), optical coherence tomography (OCT), fluorescence retinography (FR), and autofluorescence (AF). Statistical analysis employed the Student's <i>t</i>-test for paired samples at a 95% confidence level (p-value ≤ 0.05).</p><p><strong>Results: </strong>LogMAR-based visual acuity assessment demonstrated an improvement in mean value from 0.62 to 0.53 logMAR, with a statistically significant p-value of 0.001. Visual field examination, based on mean deviation (MD), pattern standard deviation (PSD), and fundal perimeter deviation index (FPDI) parameters, showed improvement from -19.87 dB to -19.45 dB, 9.77 dB to 9.76 dB, and 37% to 39%, respectively, although with non-significant p-values of 0.366, 0.446, and 0.245, respectively. No adverse effects or abnormalities in optical coherence tomography (OCT) and electroretinogram (ERG) were observed during the follow-up period.</p><p><strong>Conclusion: </strong>In this short-term study, PBM appeared to have the potential to enhance BCVA and fundus automated perimeter in RP patients without causing significant adverse events. However, further assessment with a larger patient cohort and longer follow-up is warranted to ascertain the efficacy of this technique in these patients.</p>","PeriodicalId":93945,"journal":{"name":"Clinical ophthalmology (Auckland, N.Z.)","volume":"18 ","pages":"3715-3724"},"PeriodicalIF":0.0000,"publicationDate":"2024-12-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11651134/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical ophthalmology (Auckland, N.Z.)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2147/OPTH.S483722","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: To assess the short-term effects of Multiwavelength Photobiomodulation (LumiThera Valeda Light Delivery System) on retinal functional behavior in patients with retinitis pigmentosa (RP).

Materials and methods: Twelve RP patients (24 eyes) underwent treatment involving nine photobiomodulation (PBM) sessions using the Valeda system, which emits three distinct wavelengths within the yellow (590 nm; 4 mW/cm2), red (660 nm; 65 mW/cm2), and near-infrared (NIR) (850 nm; 0.6 mW/cm2) spectrum. All evaluations were conducted four weeks post-therapy. The treated eye was compared with baseline (pre-therapy). Following nine PBM sessions, assessments included best-corrected visual acuity (BCVA), retinal sensitivity, and characteristics of the correction area via fundus automated perimetry using the Compass system. Additionally, a functional and structural assessment of the retina was performed using multifocal electroretinography (ERG), optical coherence tomography (OCT), fluorescence retinography (FR), and autofluorescence (AF). Statistical analysis employed the Student's t-test for paired samples at a 95% confidence level (p-value ≤ 0.05).

Results: LogMAR-based visual acuity assessment demonstrated an improvement in mean value from 0.62 to 0.53 logMAR, with a statistically significant p-value of 0.001. Visual field examination, based on mean deviation (MD), pattern standard deviation (PSD), and fundal perimeter deviation index (FPDI) parameters, showed improvement from -19.87 dB to -19.45 dB, 9.77 dB to 9.76 dB, and 37% to 39%, respectively, although with non-significant p-values of 0.366, 0.446, and 0.245, respectively. No adverse effects or abnormalities in optical coherence tomography (OCT) and electroretinogram (ERG) were observed during the follow-up period.

Conclusion: In this short-term study, PBM appeared to have the potential to enhance BCVA and fundus automated perimeter in RP patients without causing significant adverse events. However, further assessment with a larger patient cohort and longer follow-up is warranted to ascertain the efficacy of this technique in these patients.

多波长光生物调节治疗视网膜色素变性的短期效果
目的:评价多波长光生物调节(LumiThera Valeda光传输系统)对色素性视网膜炎(RP)患者视网膜功能行为的短期影响。材料和方法:12名RP患者(24只眼睛)接受了使用Valeda系统的9次光生物调节(PBM)治疗,该系统在黄色内发射三种不同的波长(590 nm;4 mW/cm2),红色(660 nm;65 mW/cm2)和近红外(NIR) (850 nm;0.6 mW/cm2)频谱。所有评估均在治疗后4周进行。将治疗后的眼睛与基线(治疗前)进行比较。在9次PBM治疗后,评估包括最佳矫正视力(BCVA)、视网膜敏感度和使用Compass系统通过眼底自动视距测量矫正区域的特征。此外,使用多焦视网膜电图(ERG)、光学相干断层扫描(OCT)、荧光视网膜图(FR)和自体荧光(AF)对视网膜进行功能和结构评估。统计分析采用配对样本的学生t检验,置信水平为95% (p值≤0.05)。结果:基于logMAR的视力评估显示,平均值从0.62 logMAR提高到0.53 logMAR, p值为0.001,具有统计学意义。基于平均偏差(MD)、模式标准差(PSD)和基本周长偏差指数(FPDI)参数的视野检查显示,分别从-19.87 dB改善到-19.45 dB,从9.77 dB改善到9.76 dB,从37%改善到39%,尽管p值分别为0.366、0.446和0.245,但无统计学意义。随访期间未见不良反应或光学相干断层扫描(OCT)和视网膜电图(ERG)异常。结论:在这项短期研究中,PBM似乎有可能增强RP患者的BCVA和眼底自动周长,而不会引起明显的不良事件。然而,进一步评估更大的患者队列和更长时间的随访是必要的,以确定该技术在这些患者中的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
4.10
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信