Quantitative Liver Fat Assessment by Handheld Point-of-Care Ultrasound: A Technical Implementation and Pilot Study in Adults

IF 2.4 3区 医学 Q2 ACOUSTICS
Dorathy Tamayo-Murillo , Jake T. Weeks , Cody A. Keller , Michael Andre , Celene Gonzalez , Andrew Li , Eduardo Grunvald , Joy Liau , Sedighe Hosseini Shabanan , Tanya Wolfson , Jingyi Zuo , Adam Robinson , Carolina Amador Carrascal , Nevada Sanchez , Scott B. Reeder , Aiguo Han , Claude B. Sirlin
{"title":"Quantitative Liver Fat Assessment by Handheld Point-of-Care Ultrasound: A Technical Implementation and Pilot Study in Adults","authors":"Dorathy Tamayo-Murillo ,&nbsp;Jake T. Weeks ,&nbsp;Cody A. Keller ,&nbsp;Michael Andre ,&nbsp;Celene Gonzalez ,&nbsp;Andrew Li ,&nbsp;Eduardo Grunvald ,&nbsp;Joy Liau ,&nbsp;Sedighe Hosseini Shabanan ,&nbsp;Tanya Wolfson ,&nbsp;Jingyi Zuo ,&nbsp;Adam Robinson ,&nbsp;Carolina Amador Carrascal ,&nbsp;Nevada Sanchez ,&nbsp;Scott B. Reeder ,&nbsp;Aiguo Han ,&nbsp;Claude B. Sirlin","doi":"10.1016/j.ultrasmedbio.2024.11.005","DOIUrl":null,"url":null,"abstract":"<div><h3>Objectives</h3><div>To implement, examine the feasibility of, and evaluate the performance of quantitative ultrasound (QUS) with a handheld point-of-care US (POCUS) device for assessing liver fat in adults.</div></div><div><h3>Materials and Methods</h3><div>This prospective IRB-approved, HIPAA-compliant pilot study enrolled adults with overweight or obesity. Participants underwent chemical-shift-encoded magnetic resonance imaging to estimate proton density fat fraction (PDFF) and, within 1 mo, QUS with a POCUS device by expert sonographers and novice operators (no prior US scanning experience). Radiofrequency data from the liver collected with the POCUS device were analyzed offline using probe-specific calibrations to estimate two QUS parameters: attenuation coefficient (AC) and backscatter coefficient (BSC). Area under the receiver operating characteristic curve (AUC) of each parameter was estimated for classifying presence/absence of hepatic steatosis (defined as PDFF ≥ 5%). Spearman rank correlation between each parameter and PDFF was estimated and its significance assessed.</div></div><div><h3>Results</h3><div>Of 18 participants (mean age, 43 y ± 14; 17 women), 8 had hepatic steatosis (PDFF ≥ 5%). Both AC and BSC classified hepatic steatosis accurately with AUCs of 0.96–0.97 for expert and 0.88–0.89 for novice operators (<em>p</em> &lt; 0.01 for all) and correlated significantly with PDFF with rho's of 0.65–0.69 for expert and 0.58–0.65 for novice operators (<em>p</em> &lt; 0.02 for all).</div></div><div><h3>Conclusion</h3><div>QUS can be implemented on a POCUS device and can be performed by expert or novice operators after limited training in adults with overweight or obesity with promising initial results.</div></div>","PeriodicalId":49399,"journal":{"name":"Ultrasound in Medicine and Biology","volume":"51 3","pages":"Pages 475-483"},"PeriodicalIF":2.4000,"publicationDate":"2024-12-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ultrasound in Medicine and Biology","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0301562924004265","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ACOUSTICS","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives

To implement, examine the feasibility of, and evaluate the performance of quantitative ultrasound (QUS) with a handheld point-of-care US (POCUS) device for assessing liver fat in adults.

Materials and Methods

This prospective IRB-approved, HIPAA-compliant pilot study enrolled adults with overweight or obesity. Participants underwent chemical-shift-encoded magnetic resonance imaging to estimate proton density fat fraction (PDFF) and, within 1 mo, QUS with a POCUS device by expert sonographers and novice operators (no prior US scanning experience). Radiofrequency data from the liver collected with the POCUS device were analyzed offline using probe-specific calibrations to estimate two QUS parameters: attenuation coefficient (AC) and backscatter coefficient (BSC). Area under the receiver operating characteristic curve (AUC) of each parameter was estimated for classifying presence/absence of hepatic steatosis (defined as PDFF ≥ 5%). Spearman rank correlation between each parameter and PDFF was estimated and its significance assessed.

Results

Of 18 participants (mean age, 43 y ± 14; 17 women), 8 had hepatic steatosis (PDFF ≥ 5%). Both AC and BSC classified hepatic steatosis accurately with AUCs of 0.96–0.97 for expert and 0.88–0.89 for novice operators (p < 0.01 for all) and correlated significantly with PDFF with rho's of 0.65–0.69 for expert and 0.58–0.65 for novice operators (p < 0.02 for all).

Conclusion

QUS can be implemented on a POCUS device and can be performed by expert or novice operators after limited training in adults with overweight or obesity with promising initial results.
手持式即时超声定量肝脂肪评估:成人技术实施和试点研究。
目的:研究手持式即时超声(POCUS)定量超声(QUS)用于成人肝脏脂肪评估的可行性,并对其性能进行评价。材料和方法:这项前瞻性的irb批准,符合hipaa标准的试点研究招募了超重或肥胖的成年人。参与者接受了化学位移编码磁共振成像,以估计质子密度脂肪分数(PDFF),并在1个月内由专家超声医师和新手操作员(没有之前的美国扫描经验)使用POCUS设备进行QUS。使用POCUS设备收集的肝脏射频数据进行离线分析,使用探针特定校准来估计两个QUS参数:衰减系数(AC)和后向散射系数(BSC)。估计每个参数的受试者工作特征曲线下面积(AUC),用于分类肝脂肪变性的存在/不存在(定义为PDFF≥5%)。估计各参数与PDFF之间的Spearman秩相关并评估其显著性。结果:18名参与者(平均年龄43岁±14岁;17例女性),8例肝脂肪变性(PDFF≥5%)。AC和BSC对肝脂肪变性的诊断准确率分别为0.96 ~ 0.97、0.88 ~ 0.89 (p均< 0.01),与PDFF的相关系数分别为0.65 ~ 0.69、0.58 ~ 0.65 (p均< 0.02)。结论:QUS可以在POCUS设备上实施,可以由专家或新手操作员在有限的培训后对超重或肥胖的成年人进行,初步效果良好。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
6.20
自引率
6.90%
发文量
325
审稿时长
70 days
期刊介绍: Ultrasound in Medicine and Biology is the official journal of the World Federation for Ultrasound in Medicine and Biology. The journal publishes original contributions that demonstrate a novel application of an existing ultrasound technology in clinical diagnostic, interventional and therapeutic applications, new and improved clinical techniques, the physics, engineering and technology of ultrasound in medicine and biology, and the interactions between ultrasound and biological systems, including bioeffects. Papers that simply utilize standard diagnostic ultrasound as a measuring tool will be considered out of scope. Extended critical reviews of subjects of contemporary interest in the field are also published, in addition to occasional editorial articles, clinical and technical notes, book reviews, letters to the editor and a calendar of forthcoming meetings. It is the aim of the journal fully to meet the information and publication requirements of the clinicians, scientists, engineers and other professionals who constitute the biomedical ultrasonic community.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信