Assessment of thyroid dose in orthopantomogram imaging with different thyroid shield materials: a Monte Carlo simulation study.

IF 0.8 4区 环境科学与生态学 Q4 ENVIRONMENTAL SCIENCES
Hassan Vafapour, Soraya Panah, Payman Rafiepour, Seyedeh Roghayeh Panahi
{"title":"Assessment of thyroid dose in orthopantomogram imaging with different thyroid shield materials: a Monte Carlo simulation study.","authors":"Hassan Vafapour, Soraya Panah, Payman Rafiepour, Seyedeh Roghayeh Panahi","doi":"10.1093/rpd/ncae221","DOIUrl":null,"url":null,"abstract":"<p><p>Radiation protection in dental radiography can be achieved by adjusting the image field size, exposure, and filtration parameters, and using protective lead shields. The aim of this study is to assess the radiation dose delivered to the thyroid in a phantom irradiated by an orthopantomogram (OPG) system using Geant4 simulation toolkit. Recently, researchers have been trying to find an alternative material to the lead thyroid shield so that the OPG image has minimal metal artifacts. In this study, several materials were introduced as alternatives to lead thyroid shields. The results showed that Pb, Bi, Bi2O3, stainless steel, polyurethane-Bi2O3 (50%-50% mixture), and polyurethane-W (50%-50% mixture) shields provide a thyroid dose reduction of up to 12.0%, 12.3%, 12.0%, 11.6%, 11.8%, and 12.0%, respectively. For the truncated thyroid shields, these values are up to 10.5%, 10.3%, 10.3%, 9.80%, 10.0%, and 10.1%, respectively. Therefore, Bi and Bi2O3 can be suitable alternatives to lead thyroid shields.</p>","PeriodicalId":20795,"journal":{"name":"Radiation protection dosimetry","volume":" ","pages":""},"PeriodicalIF":0.8000,"publicationDate":"2024-12-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiation protection dosimetry","FirstCategoryId":"93","ListUrlMain":"https://doi.org/10.1093/rpd/ncae221","RegionNum":4,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENVIRONMENTAL SCIENCES","Score":null,"Total":0}
引用次数: 0

Abstract

Radiation protection in dental radiography can be achieved by adjusting the image field size, exposure, and filtration parameters, and using protective lead shields. The aim of this study is to assess the radiation dose delivered to the thyroid in a phantom irradiated by an orthopantomogram (OPG) system using Geant4 simulation toolkit. Recently, researchers have been trying to find an alternative material to the lead thyroid shield so that the OPG image has minimal metal artifacts. In this study, several materials were introduced as alternatives to lead thyroid shields. The results showed that Pb, Bi, Bi2O3, stainless steel, polyurethane-Bi2O3 (50%-50% mixture), and polyurethane-W (50%-50% mixture) shields provide a thyroid dose reduction of up to 12.0%, 12.3%, 12.0%, 11.6%, 11.8%, and 12.0%, respectively. For the truncated thyroid shields, these values are up to 10.5%, 10.3%, 10.3%, 9.80%, 10.0%, and 10.1%, respectively. Therefore, Bi and Bi2O3 can be suitable alternatives to lead thyroid shields.

使用不同甲状腺屏蔽材料进行正位像成像时的甲状腺剂量评估:蒙特卡罗模拟研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Radiation protection dosimetry
Radiation protection dosimetry 环境科学-公共卫生、环境卫生与职业卫生
CiteScore
1.40
自引率
10.00%
发文量
223
审稿时长
6-12 weeks
期刊介绍: Radiation Protection Dosimetry covers all aspects of personal and environmental dosimetry and monitoring, for both ionising and non-ionising radiations. This includes biological aspects, physical concepts, biophysical dosimetry, external and internal personal dosimetry and monitoring, environmental and workplace monitoring, accident dosimetry, and dosimetry related to the protection of patients. Particular emphasis is placed on papers covering the fundamentals of dosimetry; units, radiation quantities and conversion factors. Papers covering archaeological dating are included only if the fundamental measurement method or technique, such as thermoluminescence, has direct application to personal dosimetry measurements. Papers covering the dosimetric aspects of radon or other naturally occurring radioactive materials and low level radiation are included. Animal experiments and ecological sample measurements are not included unless there is a significant relevant content reason.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信