{"title":"Within- and between-subject biological variation data for whole blood HbA<sub>1c</sub> from 38 apparently healthy Turkish subjects.","authors":"Murat Keleş, Gönül Ünver Şeker","doi":"10.1080/00365513.2024.2439394","DOIUrl":null,"url":null,"abstract":"<p><p>HbA<sub>1c</sub> plays an important role in the diagnosis and treatment of diabetes and is a valuable biomarker for evaluating glycemic control and predicting the risk of vascular complications. The study aimed to determine the biological variation (BV) for HbA<sub>1c</sub> and thereby contribute to analytical performance specifications, reference change values, and index of individuality. Fasting venous whole blood samples were collected from 38 presumably healthy subjects (20 females, 18 males) once a week for ten weeks, and analyzed in duplicate using the Roche Cobas c501 analyzer. BioVar, an online R-based biological variation analysis tool, was used for the statistical analysis. BV values were obtained by analysis of variance (ANOVA) after outlier detection, normality tests, steady-state, and homogeneity checks. The within-subject biological variation for HbA<sub>1c</sub> was 2.9%, and the between-subject biological variation was 7.9%. The index of the individuality of HbA<sub>1c</sub> was 0.37. Derived desirable analytical goals for imprecision, bias, total allowable error, and maximum expanded allowable measurement uncertainty were 1.4%, 1.8%, 4.2%, and 2.9% respectively. The reference change value is more appropriate for interpreting HbA1c results than a population-based reference interval.</p>","PeriodicalId":21474,"journal":{"name":"Scandinavian Journal of Clinical & Laboratory Investigation","volume":" ","pages":"1-5"},"PeriodicalIF":1.3000,"publicationDate":"2024-12-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Scandinavian Journal of Clinical & Laboratory Investigation","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1080/00365513.2024.2439394","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"MEDICINE, RESEARCH & EXPERIMENTAL","Score":null,"Total":0}
引用次数: 0

Abstract

HbA1c plays an important role in the diagnosis and treatment of diabetes and is a valuable biomarker for evaluating glycemic control and predicting the risk of vascular complications. The study aimed to determine the biological variation (BV) for HbA1c and thereby contribute to analytical performance specifications, reference change values, and index of individuality. Fasting venous whole blood samples were collected from 38 presumably healthy subjects (20 females, 18 males) once a week for ten weeks, and analyzed in duplicate using the Roche Cobas c501 analyzer. BioVar, an online R-based biological variation analysis tool, was used for the statistical analysis. BV values were obtained by analysis of variance (ANOVA) after outlier detection, normality tests, steady-state, and homogeneity checks. The within-subject biological variation for HbA1c was 2.9%, and the between-subject biological variation was 7.9%. The index of the individuality of HbA1c was 0.37. Derived desirable analytical goals for imprecision, bias, total allowable error, and maximum expanded allowable measurement uncertainty were 1.4%, 1.8%, 4.2%, and 2.9% respectively. The reference change value is more appropriate for interpreting HbA1c results than a population-based reference interval.

HbA1c 在糖尿病的诊断和治疗中发挥着重要作用,是评估血糖控制和预测血管并发症风险的重要生物标志物。该研究旨在确定 HbA1c 的生物变异 (BV),从而为分析性能规范、参考变化值和个体化指数做出贡献。研究人员从 38 名假定健康的受试者(女性 20 人,男性 18 人)中采集了空腹静脉全血样本,每周一次,连续采集十周,并使用罗氏 Cobas c501 分析仪进行了一式两份的分析。统计分析使用了基于 R 的在线生物变异分析工具 BioVar。经过离群点检测、正态检验、稳态检验和同质性检验后,通过方差分析(ANOVA)得出生物变异值。HbA1c 的受试者内生物变异为 2.9%,受试者间生物变异为 7.9%。HbA1c 的个体化指数为 0.37。得出的不精确度、偏差、总允许误差和最大扩展允许测量不确定性的理想分析目标分别为 1.4%、1.8%、4.2% 和 2.9%。参考变化值比基于人群的参考区间更适合解释 HbA1c 结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
3.50
自引率
4.80%
发文量
85
审稿时长
4-8 weeks
期刊介绍: The Scandinavian Journal of Clinical and Laboratory Investigation is an international scientific journal covering clinically oriented biochemical and physiological research. Since the launch of the journal in 1949, it has been a forum for international laboratory medicine, closely related to, and edited by, The Scandinavian Society for Clinical Chemistry. The journal contains peer-reviewed articles, editorials, invited reviews, and short technical notes, as well as several supplements each year. Supplements consist of monographs, and symposium and congress reports covering subjects within clinical chemistry and clinical physiology.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信