Evaluating the potential for iodinated radiocontrast agents to interfere with ADAMTS13 activity testing via fluorescence resonance energy transfer methodology.

IF 2.3 4区 医学 Q2 PATHOLOGY
Jeremy W Jacobs, Melissa S Stuart, Julie I Tange, Rachel R Leger, Aneel A Ashrani, Dong Chen, Rajiv K Pruthi, Meera Sridharan, Jansen N Seheult
{"title":"Evaluating the potential for iodinated radiocontrast agents to interfere with ADAMTS13 activity testing via fluorescence resonance energy transfer methodology.","authors":"Jeremy W Jacobs, Melissa S Stuart, Julie I Tange, Rachel R Leger, Aneel A Ashrani, Dong Chen, Rajiv K Pruthi, Meera Sridharan, Jansen N Seheult","doi":"10.1093/ajcp/aqae160","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>Fluorescence resonance energy transfer (FRET)-based ADAMTS13 activity assays are critical for the diagnosis of thrombotic thrombocytopenic purpura. However, these assays are susceptible to interference. As iodide has been suggested to interfere in laboratory testing via fluorophore quenching or promotion, we aimed to determine whether iodinated contrast (Omnipaque) interferes with the ATS-13 ADAMTS13 Activity Assay 2.0.</p><p><strong>Methods: </strong>We evaluated the excitation, emission, and absorbance spectrum of Omnipaque alone and spiked in patient plasma with known ADAMTS13 activity and ADAMTS13 activity on Omnipaque alone, an abnormal control of patient plasma previously observed to display elevated baseline relative fluorescent units, and variable concentrations of patient plasma with known ADAMTS13 activity spiked with Omnipaque.</p><p><strong>Results: </strong>No atypical fluorescent peaks were observed on any sample (Omnipaque alone or spiked in plasma) between 250 and 700 nm. There was no difference in the mean ADAMTS13 activity among the various concentrations of plasma spiked with Omnipaque or plasma spiked with saline.</p><p><strong>Conclusions: </strong>Iodinated contrast does not appear to interfere-either via spectral overlap of the fluorophore or through physiologic inhibition of the ADAMTS13 enzyme-with ADAMTS13 activity FRET-based assays based on the findings from this in vitro analysis. Delaying sample collection for ADAMTS13 activity testing from suspected patients with thrombotic thrombocytopenic purpura following administration of iodinated radiocontrast agents is not necessary, and recent contrast administration should not yield erroneous ADAMTS13 activity results.</p>","PeriodicalId":7506,"journal":{"name":"American journal of clinical pathology","volume":" ","pages":""},"PeriodicalIF":2.3000,"publicationDate":"2024-12-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"American journal of clinical pathology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1093/ajcp/aqae160","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"PATHOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: Fluorescence resonance energy transfer (FRET)-based ADAMTS13 activity assays are critical for the diagnosis of thrombotic thrombocytopenic purpura. However, these assays are susceptible to interference. As iodide has been suggested to interfere in laboratory testing via fluorophore quenching or promotion, we aimed to determine whether iodinated contrast (Omnipaque) interferes with the ATS-13 ADAMTS13 Activity Assay 2.0.

Methods: We evaluated the excitation, emission, and absorbance spectrum of Omnipaque alone and spiked in patient plasma with known ADAMTS13 activity and ADAMTS13 activity on Omnipaque alone, an abnormal control of patient plasma previously observed to display elevated baseline relative fluorescent units, and variable concentrations of patient plasma with known ADAMTS13 activity spiked with Omnipaque.

Results: No atypical fluorescent peaks were observed on any sample (Omnipaque alone or spiked in plasma) between 250 and 700 nm. There was no difference in the mean ADAMTS13 activity among the various concentrations of plasma spiked with Omnipaque or plasma spiked with saline.

Conclusions: Iodinated contrast does not appear to interfere-either via spectral overlap of the fluorophore or through physiologic inhibition of the ADAMTS13 enzyme-with ADAMTS13 activity FRET-based assays based on the findings from this in vitro analysis. Delaying sample collection for ADAMTS13 activity testing from suspected patients with thrombotic thrombocytopenic purpura following administration of iodinated radiocontrast agents is not necessary, and recent contrast administration should not yield erroneous ADAMTS13 activity results.

通过荧光共振能量转移方法评估碘化放射造影剂干扰 ADAMTS13 活性检测的可能性。
目的:基于荧光共振能量转移(FRET)的ADAMTS13活性测定是诊断血栓性血小板减少性紫癜的关键。然而,这些检测容易受到干扰。由于碘化物被认为会通过荧光团猝灭或促进来干扰实验室检测,我们旨在确定碘化对比剂(Omnipaque)是否会干扰ATS-13 ADAMTS13活性测定2.0。方法:我们评估了Omnipaque单独和加标在已知ADAMTS13活性的患者血浆中的激发、发射和吸收光谱,以及Omnipaque单独加标在已知ADAMTS13活性的患者血浆中的ADAMTS13活性,之前观察到的患者血浆的异常对照显示基线相对荧光单位升高,以及已知ADAMTS13活性的患者血浆的不同浓度加标Omnipaque。结果:在250 ~ 700 nm范围内,任何样品(Omnipaque单独或在血浆中添加)均未观察到非典型荧光峰。在不同浓度的Omnipaque和生理盐水血浆中,ADAMTS13的平均活性没有差异。结论:碘化对比剂似乎不会干扰——无论是通过荧光团的光谱重叠,还是通过ADAMTS13酶的生理抑制——基于fret的ADAMTS13活性测定,基于这项体外分析的结果。对于疑似血栓性血小板减少性紫癜患者,在服用碘化放射造影剂后延迟ADAMTS13活性检测的样本采集是没有必要的,近期服用造影剂不应产生错误的ADAMTS13活性结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
7.70
自引率
2.90%
发文量
367
审稿时长
3-6 weeks
期刊介绍: The American Journal of Clinical Pathology (AJCP) is the official journal of the American Society for Clinical Pathology and the Academy of Clinical Laboratory Physicians and Scientists. It is a leading international journal for publication of articles concerning novel anatomic pathology and laboratory medicine observations on human disease. AJCP emphasizes articles that focus on the application of evolving technologies for the diagnosis and characterization of diseases and conditions, as well as those that have a direct link toward improving patient care.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信