{"title":"A carbon quantum dot@mesoporous silicon composite-based fluorescent probe for chlortetracycline hydrochloride and gentamicin†","authors":"Lina Gao and Jing Wang","doi":"10.1039/D4NJ04517C","DOIUrl":null,"url":null,"abstract":"<p >Antibiotics, such as chlortetracycline hydrochloride (CTC) and gentamicin (GTM), pose a significant threat to human health and ecosystems. Therefore, stable analytical tools to identify CTC and GTM are of great practical importance. For accuracy and sensitivity, mesoporous SBA-15 silica was chosen as the solid support material to enhance the photostability of the detection system. Carbon quantum dots (CDs) as fluorescence signal emitters were introduced into SBA-15, and a fluorescent nanoprobe, CDs@SBA-15, exhibiting remarkable selectivity and sensitivity was constructed. The composite-based nanoprobe showed remarkable selectivity toward GTM, enabling the sensitive detection of GTM. The fluorescence spectrum of CDs@SBA-15 was altered in a “turn-on” manner when GTM was present, and the detection limit was 29 nM. Compared with the non-fluorescence response of CDs toward GTM, the superior fluorescence response of CDs@SBA-15 toward GTM was due to the immobilization of the CDs and the spatially restricted domain effect of the pore channels of SBA-15. In addition, the nanoprobe showed excellent selectivity for CTC in a “turn-off” manner and could sensitively detect CTC in the ranges of 0–4.0 and 4.0–100.0 μM with a detection limit of 113 nM. Moreover, the feasibility of the fluorescent nanoprobe was verified using tap water samples.</p>","PeriodicalId":95,"journal":{"name":"New Journal of Chemistry","volume":" 1","pages":" 246-256"},"PeriodicalIF":2.5000,"publicationDate":"2024-11-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"New Journal of Chemistry","FirstCategoryId":"92","ListUrlMain":"https://pubs.rsc.org/en/content/articlelanding/2025/nj/d4nj04517c","RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

Abstract

Antibiotics, such as chlortetracycline hydrochloride (CTC) and gentamicin (GTM), pose a significant threat to human health and ecosystems. Therefore, stable analytical tools to identify CTC and GTM are of great practical importance. For accuracy and sensitivity, mesoporous SBA-15 silica was chosen as the solid support material to enhance the photostability of the detection system. Carbon quantum dots (CDs) as fluorescence signal emitters were introduced into SBA-15, and a fluorescent nanoprobe, CDs@SBA-15, exhibiting remarkable selectivity and sensitivity was constructed. The composite-based nanoprobe showed remarkable selectivity toward GTM, enabling the sensitive detection of GTM. The fluorescence spectrum of CDs@SBA-15 was altered in a “turn-on” manner when GTM was present, and the detection limit was 29 nM. Compared with the non-fluorescence response of CDs toward GTM, the superior fluorescence response of CDs@SBA-15 toward GTM was due to the immobilization of the CDs and the spatially restricted domain effect of the pore channels of SBA-15. In addition, the nanoprobe showed excellent selectivity for CTC in a “turn-off” manner and could sensitively detect CTC in the ranges of 0–4.0 and 4.0–100.0 μM with a detection limit of 113 nM. Moreover, the feasibility of the fluorescent nanoprobe was verified using tap water samples.

Abstract Image

基于碳量子点@介孔硅复合材料的盐酸金霉素和庆大霉素†荧光探针
氯霉素(CTC)和庆大霉素(GTM)等抗生素对人类健康和生态系统构成重大威胁。因此,建立稳定的分析工具来鉴别CTC和GTM具有重要的现实意义。为了准确性和灵敏度,选择介孔SBA-15二氧化硅作为固体支撑材料,以提高检测系统的光稳定性。将碳量子点(CDs)作为荧光信号发射体引入SBA-15中,构建了具有良好选择性和灵敏度的荧光纳米探针CDs@SBA-15。复合纳米探针对GTM具有明显的选择性,可实现对GTM的灵敏检测。当GTM存在时,CDs@SBA-15的荧光光谱呈“开启”状态,检测限为29 nM。与CDs对GTM的非荧光响应相比,CDs@SBA-15对GTM的优越荧光响应是由于CDs的固定化和SBA-15孔通道的空间限制域效应。此外,该纳米探针对CTC具有良好的“关断”选择性,可在0 ~ 4.0 μM和4.0 ~ 100.0 μM范围内对CTC进行灵敏检测,检出限为113 nM。此外,利用自来水样品验证了荧光纳米探针的可行性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
New Journal of Chemistry
New Journal of Chemistry 化学-化学综合
CiteScore
5.30
自引率
6.10%
发文量
1832
审稿时长
2 months
期刊介绍: A journal for new directions in chemistry
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信