Simulation-based process optimization of full-scale advanced wastewater treatment systems using powdered activated carbon.

IF 2.5 4区 环境科学与生态学 Q3 ENGINEERING, ENVIRONMENTAL
Water Science and Technology Pub Date : 2024-12-01 Epub Date: 2024-11-21 DOI:10.2166/wst.2024.382
Hana Atallah Al-Asad, Jens Alex, Janna Parniske, Tobias Morck
{"title":"Simulation-based process optimization of full-scale advanced wastewater treatment systems using powdered activated carbon.","authors":"Hana Atallah Al-Asad, Jens Alex, Janna Parniske, Tobias Morck","doi":"10.2166/wst.2024.382","DOIUrl":null,"url":null,"abstract":"<p><p>This study extends a previously developed competitive modeling approach for predicting the adsorption of organic micropollutants (OMPs) on powdered activated carbon (PAC) in full-scale advanced wastewater treatment. The approach incorporates adsorption analysis for organic matter fractionation, assumes pseudo-first order kinetics and differentiates between fresh and partially loaded PAC through fraction segregation. Validation through full-scale measurement campaigns reveals successful model predictions of OMP removal, underestimating, however, diclofenac removals by 15-20%. Based on model testing, the impact of excess PAC return to the biological stage enhanced OMP removal, reaching up to 15% improvement for benzotriazole, carbamazepine and metoprolol, but no evident improvement of diclofenac removal. Intermittent PAC dosing revealed rapid process response, where organic matter concentration increased within 2 h after PAC cut-off. The simulation-based study demonstrated that during rain events, the overall OMP removal efficiency in the entire wastewater treatment plant was reduced by approximately 50% due to a shift of OMP concentration and a shortened hydraulic retention time in the biological and adsorption stages. Testing of various PAC dosing strategies revealed potential PAC savings of 10-15% compared to inflow-proportional dosing by using predefined OMP removal grades or maximum allowable effluent OMP concentrations as criteria for PAC dosing.</p>","PeriodicalId":23653,"journal":{"name":"Water Science and Technology","volume":"90 11","pages":"3008-3028"},"PeriodicalIF":2.5000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Water Science and Technology","FirstCategoryId":"93","ListUrlMain":"https://doi.org/10.2166/wst.2024.382","RegionNum":4,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/11/21 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"ENGINEERING, ENVIRONMENTAL","Score":null,"Total":0}
引用次数: 0

Abstract

This study extends a previously developed competitive modeling approach for predicting the adsorption of organic micropollutants (OMPs) on powdered activated carbon (PAC) in full-scale advanced wastewater treatment. The approach incorporates adsorption analysis for organic matter fractionation, assumes pseudo-first order kinetics and differentiates between fresh and partially loaded PAC through fraction segregation. Validation through full-scale measurement campaigns reveals successful model predictions of OMP removal, underestimating, however, diclofenac removals by 15-20%. Based on model testing, the impact of excess PAC return to the biological stage enhanced OMP removal, reaching up to 15% improvement for benzotriazole, carbamazepine and metoprolol, but no evident improvement of diclofenac removal. Intermittent PAC dosing revealed rapid process response, where organic matter concentration increased within 2 h after PAC cut-off. The simulation-based study demonstrated that during rain events, the overall OMP removal efficiency in the entire wastewater treatment plant was reduced by approximately 50% due to a shift of OMP concentration and a shortened hydraulic retention time in the biological and adsorption stages. Testing of various PAC dosing strategies revealed potential PAC savings of 10-15% compared to inflow-proportional dosing by using predefined OMP removal grades or maximum allowable effluent OMP concentrations as criteria for PAC dosing.

使用粉末活性炭的全规模先进废水处理系统的基于仿真的工艺优化。
本研究扩展了之前开发的竞争建模方法,用于预测全规模先进废水处理中粉末状活性炭(PAC)对有机微污染物(OMPs)的吸附情况。该方法结合了有机物分馏吸附分析,假定了伪一阶动力学,并通过馏分分离区分了新鲜和部分负载的 PAC。通过全面的测量活动进行验证,模型成功预测了 OMP 的去除率,但低估了 15-20% 的双氯芬酸去除率。根据模型试验,过量的 PAC 返回生物阶段的影响增强了 OMP 的去除率,苯并三唑、卡马西平和美托洛尔的去除率提高了 15%,但双氯芬酸的去除率没有明显提高。间歇性 PAC 投加显示了快速的工艺响应,在 PAC 截止后 2 小时内,有机物浓度有所增加。模拟研究表明,在降雨期间,由于 OMP 浓度的变化以及生物和吸附阶段水力停留时间的缩短,整个污水处理厂的 OMP 去除效率降低了约 50%。通过使用预定的 OMP 去除等级或最大允许出水 OMP 浓度作为 PAC 投加标准,对各种 PAC 投加策略进行了测试,结果表明与流入比例投加相比,PAC 投加可能会节省 10-15% 的费用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Water Science and Technology
Water Science and Technology 环境科学-工程:环境
CiteScore
4.90
自引率
3.70%
发文量
366
审稿时长
4.4 months
期刊介绍: Water Science and Technology publishes peer-reviewed papers on all aspects of the science and technology of water and wastewater. Papers are selected by a rigorous peer review procedure with the aim of rapid and wide dissemination of research results, development and application of new techniques, and related managerial and policy issues. Scientists, engineers, consultants, managers and policy-makers will find this journal essential as a permanent record of progress of research activities and their practical applications.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信