{"title":"Visual Improvement With Wavefront-Guided Scleral Lenses for Irregular Corneal Astigmatism.","authors":"John D Gelles, Becky Su, David Kelly, Nicolas Brown, Jenny Wong, Geunyoung Yoon, Travis Pfeifer, Cameron Erdman, Peter S Hersh, Steven A Greenstein","doi":"10.1097/ICL.0000000000001152","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To report interim results of a single center, randomized, double-blind, crossover-controlled clinical trial comparing wavefront-guided (wfg) scleral lenses (SLs) to traditional scleral lenses (tSLs) for patients with a history of irregular corneal astigmatism (ICA).</p><p><strong>Methods: </strong>Thirty-one ICA eyes of 18 participants were reviewed, 23 with keratoconus, six postcorneal refractive ectasia, and two postpenetrating keratoplasty. Patients with corneal or lens opacities were not excluded from participating. Participants underwent a diagnostic lens-based fitting with a tSL with standard spherocylindrical optics. Once the tSL was finalized, a comprehensive wavefront aberrometer-based system was used to capture the residual aberration of the tSL under scotopic conditions without pharmacologic dilation, and these data were used to create a wfgSL. Once the tSL and wgfSL were finalized, a double-blinded, randomized, crossover was conducted where the participants received lens A (tSL or wgfSL) or lens B (the alternative), each worn for a 4±1 week interval. Measurements of the visual acuity (VA) and total higher-order root mean squared (HORMS) were recorded at each interval under controlled lighting conditions. At the final visit, patient subjective preference for lens A or lens B was recorded.</p><p><strong>Results: </strong>The average HORMS for a fixed 5-mm pupil was 0.68±0.31 μm for tSL and 0.29±0.18 μm for wfgSL. Wavefront-guided SL provided an average HORMS improvement of 56% ( P <0.001). All eyes showed a reduction in HORMS, ranging from 18% to 83%. Wavefront-guided SL provided an average VA improvement of 0.12±0.11 logMAR ( P <0.01). Seventy-one percent of eyes showed one line or greater improvement, 26% showed no improvement, and 3% showed a reduction of VA with the wfgSL. The average VA with tSL was 0.14±0.16 logMAR and 0.03±0.11 logMAR for wfgSL. Seventeen of 18 patients subjectively preferred wfgSL.</p><p><strong>Conclusion: </strong>In eyes with ICA, wfgSL reduced HORMS and improved VA when compared with tSL. Patients subjectively preferred wfgSL to tSL. These interim results demonstrate the feasibility and generalizability of wfgSL in a typical clinical practice environment.</p>","PeriodicalId":50457,"journal":{"name":"Eye & Contact Lens-Science and Clinical Practice","volume":" ","pages":"58-64"},"PeriodicalIF":2.0000,"publicationDate":"2025-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11753440/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Eye & Contact Lens-Science and Clinical Practice","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/ICL.0000000000001152","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/12/10 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To report interim results of a single center, randomized, double-blind, crossover-controlled clinical trial comparing wavefront-guided (wfg) scleral lenses (SLs) to traditional scleral lenses (tSLs) for patients with a history of irregular corneal astigmatism (ICA).

Methods: Thirty-one ICA eyes of 18 participants were reviewed, 23 with keratoconus, six postcorneal refractive ectasia, and two postpenetrating keratoplasty. Patients with corneal or lens opacities were not excluded from participating. Participants underwent a diagnostic lens-based fitting with a tSL with standard spherocylindrical optics. Once the tSL was finalized, a comprehensive wavefront aberrometer-based system was used to capture the residual aberration of the tSL under scotopic conditions without pharmacologic dilation, and these data were used to create a wfgSL. Once the tSL and wgfSL were finalized, a double-blinded, randomized, crossover was conducted where the participants received lens A (tSL or wgfSL) or lens B (the alternative), each worn for a 4±1 week interval. Measurements of the visual acuity (VA) and total higher-order root mean squared (HORMS) were recorded at each interval under controlled lighting conditions. At the final visit, patient subjective preference for lens A or lens B was recorded.

Results: The average HORMS for a fixed 5-mm pupil was 0.68±0.31 μm for tSL and 0.29±0.18 μm for wfgSL. Wavefront-guided SL provided an average HORMS improvement of 56% ( P <0.001). All eyes showed a reduction in HORMS, ranging from 18% to 83%. Wavefront-guided SL provided an average VA improvement of 0.12±0.11 logMAR ( P <0.01). Seventy-one percent of eyes showed one line or greater improvement, 26% showed no improvement, and 3% showed a reduction of VA with the wfgSL. The average VA with tSL was 0.14±0.16 logMAR and 0.03±0.11 logMAR for wfgSL. Seventeen of 18 patients subjectively preferred wfgSL.

Conclusion: In eyes with ICA, wfgSL reduced HORMS and improved VA when compared with tSL. Patients subjectively preferred wfgSL to tSL. These interim results demonstrate the feasibility and generalizability of wfgSL in a typical clinical practice environment.

波前引导巩膜晶状体治疗不规则角膜散光改善视力。
目的:报告一项单中心、随机、双盲、交叉对照临床试验的中期结果,比较波前引导(wfg)巩膜镜片(SLs)和传统巩膜镜片(tSLs)对不规则角膜散光(ICA)患者的治疗效果。方法:对18例31只ICA眼进行回顾性分析,其中23只为圆锥角膜,6只为角膜后屈光性扩张,2只为穿透性角膜移植。有角膜或晶状体混浊的患者没有被排除在外。参与者接受了一个诊断透镜为基础的配合与标准球圆柱光学tSL。一旦tSL被确定,一个综合的基于波前像差仪的系统被用来捕捉暗暗条件下tSL的残余像差,而不需要药物扩张,这些数据被用来创建wfgSL。一旦确定了tSL和wgfSL,进行双盲、随机、交叉试验,参与者接受镜片a (tSL或wgfSL)或镜片B(另一种),每个镜片佩戴4±1周。在受控光照条件下,记录每个间隔的视敏度(VA)和总高阶均方根(HORMS)测量值。在最后一次就诊时,记录患者对晶状体A或晶状体B的主观偏好。结果:固定5 mm瞳孔的平均HORMS: tSL为0.68±0.31 μm, wfgSL为0.29±0.18 μm。波前引导的SL平均改善了56%的HORMS(结论:与tSL相比,wfgSL降低了ICA眼的HORMS,改善了VA。与tSL相比,患者主观上更喜欢wfgSL。这些中期结果证明了wfgSL在典型临床实践环境中的可行性和普遍性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
4.50
自引率
4.30%
发文量
150
审稿时长
6-12 weeks
期刊介绍: Eye & Contact Lens: Science and Clinical Practice is the official journal of the Contact Lens Association of Ophthalmologists (CLAO), an international educational association for anterior segment research and clinical practice of interest to ophthalmologists, optometrists, and other vision care providers and researchers. Focusing especially on contact lenses, it also covers dry eye disease, MGD, infections, toxicity of drops and contact lens care solutions, topography, cornea surgery and post-operative care, optics, refractive surgery and corneal stability (eg, UV cross-linking). Peer-reviewed and published six times annually, it is a highly respected scientific journal in its field.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信