Momoko Sakata, Yuki Imaizumi, Takumi Iwasawa, Kazunori Kato, Tatsuro Goda
{"title":"Semiconductor Transistor-Based Detection of Epithelial-Mesenchymal Transition via Weak Acid-Induced Proton Perturbation.","authors":"Momoko Sakata, Yuki Imaizumi, Takumi Iwasawa, Kazunori Kato, Tatsuro Goda","doi":"10.1021/acsbiomaterials.4c01707","DOIUrl":null,"url":null,"abstract":"<p><p>Developing new detection methods for the epithelial-mesenchymal transition (EMT), where epithelial cells acquire mesenchymal traits, is crucial for understanding tissue development, cancer invasion, and metastasis. Conventional <i>in vitro</i> EMT evaluation methods like permeability measurements are time-consuming and low-throughput, while the transepithelial electrical resistance measurements struggle to differentiate between cell membrane damage and tight junction (TJ) loss and are affected by cell proliferation. In this study, we developed a pH perturbation method to detect TJ barrier disruption during epithelial EMT by sensing proton leakage induced by a weak acid using a pH-responsive semiconductor. Mardin-Darby canine kidney (MDCK) epithelial cell sheets cultured on an ion-sensitive field effect transistor's gate insulator were induced into EMT by exposure to the cytokine transforming growth factor-β1 (TGF-β). Our pH perturbation method successfully detected EMT in MDCK sheets at a TGF-β concentration one-tenth of that required for conventional methods. The high sensitivity and selectivity arise from using minimal protons as indicators of TJ barrier disruption. TGF-β-induced EMT detection results using our method align with EMT-related gene and protein expression data. In drug screening with EMT inhibitors, this novel method showed similar trends to conventional ones. The pH perturbation method enables highly sensitive, real-time EMT detection, contributing to elucidating biological phenomena and pharmaceutical development.</p>","PeriodicalId":8,"journal":{"name":"ACS Biomaterials Science & Engineering","volume":" ","pages":""},"PeriodicalIF":5.4000,"publicationDate":"2024-12-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Biomaterials Science & Engineering","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1021/acsbiomaterials.4c01707","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
引用次数: 0
Abstract
Developing new detection methods for the epithelial-mesenchymal transition (EMT), where epithelial cells acquire mesenchymal traits, is crucial for understanding tissue development, cancer invasion, and metastasis. Conventional in vitro EMT evaluation methods like permeability measurements are time-consuming and low-throughput, while the transepithelial electrical resistance measurements struggle to differentiate between cell membrane damage and tight junction (TJ) loss and are affected by cell proliferation. In this study, we developed a pH perturbation method to detect TJ barrier disruption during epithelial EMT by sensing proton leakage induced by a weak acid using a pH-responsive semiconductor. Mardin-Darby canine kidney (MDCK) epithelial cell sheets cultured on an ion-sensitive field effect transistor's gate insulator were induced into EMT by exposure to the cytokine transforming growth factor-β1 (TGF-β). Our pH perturbation method successfully detected EMT in MDCK sheets at a TGF-β concentration one-tenth of that required for conventional methods. The high sensitivity and selectivity arise from using minimal protons as indicators of TJ barrier disruption. TGF-β-induced EMT detection results using our method align with EMT-related gene and protein expression data. In drug screening with EMT inhibitors, this novel method showed similar trends to conventional ones. The pH perturbation method enables highly sensitive, real-time EMT detection, contributing to elucidating biological phenomena and pharmaceutical development.
期刊介绍:
ACS Biomaterials Science & Engineering is the leading journal in the field of biomaterials, serving as an international forum for publishing cutting-edge research and innovative ideas on a broad range of topics:
Applications and Health – implantable tissues and devices, prosthesis, health risks, toxicology
Bio-interactions and Bio-compatibility – material-biology interactions, chemical/morphological/structural communication, mechanobiology, signaling and biological responses, immuno-engineering, calcification, coatings, corrosion and degradation of biomaterials and devices, biophysical regulation of cell functions
Characterization, Synthesis, and Modification – new biomaterials, bioinspired and biomimetic approaches to biomaterials, exploiting structural hierarchy and architectural control, combinatorial strategies for biomaterials discovery, genetic biomaterials design, synthetic biology, new composite systems, bionics, polymer synthesis
Controlled Release and Delivery Systems – biomaterial-based drug and gene delivery, bio-responsive delivery of regulatory molecules, pharmaceutical engineering
Healthcare Advances – clinical translation, regulatory issues, patient safety, emerging trends
Imaging and Diagnostics – imaging agents and probes, theranostics, biosensors, monitoring
Manufacturing and Technology – 3D printing, inks, organ-on-a-chip, bioreactor/perfusion systems, microdevices, BioMEMS, optics and electronics interfaces with biomaterials, systems integration
Modeling and Informatics Tools – scaling methods to guide biomaterial design, predictive algorithms for structure-function, biomechanics, integrating bioinformatics with biomaterials discovery, metabolomics in the context of biomaterials
Tissue Engineering and Regenerative Medicine – basic and applied studies, cell therapies, scaffolds, vascularization, bioartificial organs, transplantation and functionality, cellular agriculture